Figure 13.23 Oscillograms of an actual short-circuit test carried out on a power distribution panel (Courtesy ECS)... Figure 13.23 Oscillograms of an actual short-circuit test carried out on a power distribution panel (Courtesy ECS)...
For more clarity we have reproduced in Figure 14.3 an actual test circuit and in Figure 14.4, the oscillograms of the test results of a short-circuit test successfully carried out on an LT power distribution panel (Figure 14.8) for a system fault level of 50 kAfor 1 second, at CPRI (Central Power Research Institute). From a study of these oscillograms (Figure 14.4), we can infer the following test results ... [Pg.433]

It is important to keep the test location well guarded and secured to prevent unauthorized access. The test locations must be secured with barrier tapes or other means to warn people of the hazards. If power distribution panels or switchboards are monitored, all openings created as the result of instrument setup should be sealed to prevent entry by rodents and other pests. All these steps are necessary to ensure that the tests will be completed without accidents. [Pg.202]

If feasible, raised panel computer-room type floors should not be used. Where raised floors must be used to accommodate wiring and cables, they should be constructed entirely of noncombustible materials and provided with floor panels easily removable by hand. Power distribution in the subfloor space should be in conduit. Redundant data highway cables should be run as remotely from each other as possible and not mixed with power cables. [Pg.304]

Figure 9.11 Interior view of a pressurized -p- power distribution unit control panels (foreground) and 1 kV switchgear (background). Figure 9.11 Interior view of a pressurized -p- power distribution unit control panels (foreground) and 1 kV switchgear (background).
This consists of the installation of the SIS logic solver into cabinets with the appropriate termination panels for connecting the process signals to the logic solver I/O modules. Power supplies and power distribution for the logic solver and field devices are also normally included. [Pg.83]

The sources of risk identified include radio gears and homing aids to support the aviation, military radio equipment, optoelectronic systems, back-up electric power sources, electric generators, central monitor panel, microwave communication centres and cellular phones, computer networks including power supply imits, computers and monitors, telephone switchboard, welding equipments, transformer stations, electric power distribution and various appliances including domestic ones (Kubicek, L. 2008). The stay of unit employees in the NIEMF of radar side lobes was assessed as a critical risk subjected to a more detailed examination. [Pg.722]

Applications and uses telephone line splice cases, switches, connectors, housings, improved impact brake and fuel line clips, wheel covers, headlamp bezels and covers, panels, power distribution boxes, cold temperature air bag doors, automotive safety systems, wheel covers, impact fascias, improved impact appliance lids, power tools, panels, and housings. [Pg.179]

The basic horizontahy polarized panel antenna can be modihed to produce circular polarization through the addition of verticahy polarized radiators. Panel designs offer broad bandwidth and a wide choice of radiation patterns. By selecting the appropriate number of panels located around the tower, and the proper phase and amphtude distribution to the panels, a number of azimuth patterns can be realized. The primary drawback to the panel is the power distribution network required to feed the individual radiating elements. [Pg.1551]

NFPA 70 National Fire Protection Association 70 is also known as the National Electric Code (NEC). Revisions and addenda to the code have been developed that specifically address fuel cells. Article 690 - Solar Photovoltaic Systems has been targeted for revision to include fuel cells and alternate energy sources systems. This proposal is not expected to be approved since the technological and operational differences between fuel cells and photovoltaic systems are considerable. A new article. Article 692 deals with rules covering fuel cell systems for buildings or residential dwellings. This standard addresses the electrical interface between the fuel cell system and a building s electrical distribution panel. NFPA Article 705 - Interconnected Electrical Power Production Sources has also been revised to address fuel cell power sources. [Pg.400]

Power/Propulsion - Auxiliary power of fishing vessels is normally provided by two or more diesel-electric generator sets or possibly main engine driven alternators on smaller vessels. Power distribution is by series switchboards, distribution panels and cabling systems. Emergency power sources are normally battery based. Medium speed engines (via a reduction gearing system) normally provide the propulsion power. [Pg.86]

The Lockout Planner is tasked with, proper isolation boundary points as The procedure addresses the lockout distribution panels, use of pulled air-operated valves. It also provi preparation of lockouts, including and check valves as lockout points, be used in locking out a component, sources, control power sources, all devices or control switches. [Pg.457]

Fig (3) The proposed design demands operator intervention and guidance for the manipulator control The wrist portion of the manipulator houses all the sensors and actuating mechanism In order to reduce the weight of the wrist, the power distribution and high power switches for Arms Control are housed at the manipulater base. The operator panel and monitoring system is based on a micro- computer and housed in control room A seperate microcomputer housed on the wrist controls the power drives and captures data from sensory system The two microcomputers communicate over a serial channel and coordinate their activities ... [Pg.392]

Electrical. The plant electrical system is sometimes more important than the steam system. The electrical system consists of the utihty company s entry substation, any ia-plant generating equipment, primary distribution feeders, secondary substations and transformers, final distribution cables, and various items of switch-gear, protective relays, motor starters, motors, lighting control panels, and capacitors to adjust power factor. [Pg.227]

FIGURE 11.23 Power analysis.The desired difference is >2 standard deviation units (X, - / = 8). The sample distribution in panel a is wide and only 67% of the distribution values are > 8. Therefore, with an experimental design that yields the sample distribution shown in panel a will have a power of 67% to attain the desired endpoint. In contrast, the sample distribution shown in panel b is much less broad and 97% of the area under the distribution curve is >8. Therefore, an experimental design yielding the sample distribution shown in panel B will gave a much higher power (97%) to attain the desired end point. One way to decrease the broadness of sample distributions is to increase the sample size. [Pg.253]


See other pages where Power distribution panels is mentioned: [Pg.30]    [Pg.139]    [Pg.139]    [Pg.185]    [Pg.198]    [Pg.362]    [Pg.30]    [Pg.139]    [Pg.139]    [Pg.185]    [Pg.198]    [Pg.362]    [Pg.405]    [Pg.29]    [Pg.578]    [Pg.29]    [Pg.200]    [Pg.578]    [Pg.29]    [Pg.459]    [Pg.227]    [Pg.350]    [Pg.391]    [Pg.393]    [Pg.1225]    [Pg.1231]    [Pg.578]    [Pg.272]    [Pg.272]    [Pg.272]    [Pg.27]    [Pg.95]    [Pg.433]    [Pg.475]    [Pg.23]    [Pg.165]    [Pg.1067]    [Pg.116]    [Pg.213]   