The valve control enables the vacuum to be set precisely, but is highly inefficient with regard to energy in most cases. Gas is reduced uimecessarily, only to compress it again later without making use of the energy consumed. [Pg.64]

One solution that requires a higher investment, but is more efficient and low cost to run, is to adjust the suction power of the vacuum pumps. [Pg.64]


Gas turbine power adjustments in a utility application require that the mechanical speed must remain constant due to unacceptable consequences of frequency fluctuations. The control is obtained by IGV adjustments to reduce the flow at off-design loads and to maintain the high exhaust gas temperature. [Pg.707]

Jeumont-Schneider, R. Champrade, High Power Adjustable Speed Ihr, with Synchronous Motor, Power Conversion International, Sept H i. . 1979, pp. 83-89. [Pg.301]

Gaussian pulses are frequently applied as soft pulses in modern ID, 2D, and 3D NMR experiments. The power in such pulses is adjusted in milliwatts. Hard" pulses, on the other hand, are short-duration pulses (duration in microseconds), with their power adjusted in the 1-100 W range. Figures 1.15 and 1.16 illustrate schematically the excitation profiles of hard and soft pulses, respectively. Readers wishing to know more about the use of shaped pulses for frequency-selective excitation in modern NMR experiments are referred to an excellent review on the subject (Kessler et ai, 1991). [Pg.24]

The measured SAXS curve of the calibration sample must have been pre-processed in the usual way (cf. Sects. 7.3 - 7.6). Therefore it is important to have calibration samples with a well-defined thickness27. Because synchrotron beamlines can be adjusted to a fairly wide range of radiation power, it is important to have thin calibration samples for a high-power adjustment (e.g., common SAXS with wide slit openings) and thick calibration samples for low-power adjustments (e.g., USAXS with microbeam). For calibration samples from synthetic polymers, thicknesses ranging between 0.2 mm and 3 mm are reasonable. It appears worth to be noted that not only polymers, but as well glassy carbon [88] can be used as a solid secondary standard for the calibration to absolute intensity. [Pg.106]

Exterior controls ON/OFF power, adjustable occlusion pressure, and deflation of bladder... [Pg.142]

If there is good communication between the heating elements and the sample or reference thermocouple junctions, then the control system can make its power adjustments based on one of those temperatures. If there is substantial insulation between these locations, which may be necessary for heat flow uniformity to both sample and reference or to permit the introduction of special gases, then a separate control thermocouple is used which is placed near the furnace windings. [Pg.37]

Process no solvent residues facile separation of products high diffusion rates low viscosity adjustable solvent power adjustable density inexpensive CO2 and other volatile SCFs CO2 and other volatile SCFs all all all all CO2, H2O, NH3, Ar, hydrocarbons... [Pg.10]

The rotating autoclave shown is a vessel formed by boring out the steel core of a 6-inch high-explosive shell until the thickness of the wall was about 1 9 cm. The steel cover, which is of similar thickness, is fastened down with twelve bolts and rendered gas-tight with a lead washer. The cover carries a powerful adjustable spring safety-valve,... [Pg.216]

Many people have the motor control necessary to operate a motor vehicle, but they do not have the strength required to operate manual hand-controls. Automatic or Fly-By-Wire hand-controls use external actuators (e.g., air motors, servo mechanisms, hydraulic motors) to reduce the force required to operate various vehicle primary controls. Power steering, power brakes, six-way power seats, and power adjustable steering columns can be purchased as factory options on many vehicles. [Pg.1151]

Normally the fuel cell supports base load thus, the fuel flow regulator in Fig. 14 is set to provide a constant input flow-rate for the cell fuel. The response of the fuel flow regulator is slow. The plant, however, can respond continuously to small instantaneous power adjustment by the control of the angle Sp. Any steady state power change must be followed by a corresponding change in the fuel flow-rate. If the fuel cell power increases while the fuel flow rate is maintained constant, the steady state cell utilization will increase and the cell voltage will drop. [Pg.198]

The strong reactivity feedbacks of the fast neutron spectrum core enable autonomous load following whereby the reactor power adjusts itself to match heat removal from the primary coolant solely as a consequence of inherent physical phenomena. Figure XXIII-8 shows the dependencies of the new peak cladding, core outlet, and core inlet temperatures upon the new steady state thermal power that is attained following an autonomous power change from the nominal (400 MW(th)) steady state. The results are dependent upon the value of the core radial expansion reactivity feedback coefficient. The specific value of -0.140 cents/°C... [Pg.645]

Such measurements are usually made with no throttle (pi = p, heat capacity), or with no power (P = 0 Joule-Thomson), or with the power adjusted so as to restore the temperature of the gas after it has passed through the throttle (71 = T isothermal Joule-Thomson). The equations for these special cases can be readily derived from equation (32). [Pg.10]

The Orbitrap is an electrostatic ion trap using fast Pourier transformation to obtain mass spectra. Its high mass accuracy (2—5 ppm) and resolving power (adjustable up to 100,000 fwhm) allows discrimination between isobaric interferences and ions of interest, even with a complex background. Plowever, due to the high price of the Orbitrap, there are still not many applications in the field of veterinary residue analysis. [Pg.468]

An Increase of reactivity leads to a rise In steady state reactor power and associated with this will be an Increase In system pressure until the steam flow to the turbine rises to match the increased reactor power. Adjustment of reactivity, therefore, provides a possible method of controlling pressure It acts via two important delay effects which are due to fuel conduction and the heat capacity of the primary circuit Including, the steam drum. [Pg.83]

In some transformations, the choice of solvent represents a powerful adjuster bolt for the stereochemical outcome of the reaction. Divergent stereoselectivity in the reduction of glycid ketones 131 is observed when either diethyl ether or HMPA was used with trimethoxy silane as reducing reagent in the presence of catalytic amounts of lithium methoxide (Table 3.2) [49]. Highly coordinated silicon compounds show specific reactivities in comparison to tetra-coordinated silicon compounds [50]. [Pg.161]

When the medical manipulator is part of a complex control system, eg also involving a powered wheelchair wife powered adjustable seat position and an environmental controller, then more problems occur. The integrated control system needs to take account not only of fee individual devices, but of fee potential unsafe outccane of a combination of the devices, eg attempting to pass through a doorway at speed whilst fee arm is extended, or tryii to turn fee chair abruptly whilst fee arm is carrying a load at full reach. [Pg.62]


See other pages where Power Adjustment is mentioned: [Pg.268]    [Pg.219]    [Pg.237]    [Pg.6182]    [Pg.259]    [Pg.617]    [Pg.321]    [Pg.226]    [Pg.6181]    [Pg.216]    [Pg.62]    [Pg.608]    [Pg.1151]    [Pg.304]    [Pg.102]    [Pg.318]    [Pg.88]    [Pg.620]    [Pg.627]    [Pg.64]    [Pg.447]    [Pg.1240]    [Pg.1216]    [Pg.331]   


SEARCH



Adjusting the Resolving Power of a Sector Instrument

Powered seat adjuster

Time-adjusted power

© 2024 chempedia.info