Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Methods/test procedures

As regards the half-tone colouring and colour intensity, blue is used - as far as possible - for normal findings, classification, causes, indications, therapy regimen, etc., red applies to pathological findings, contraindications, complications, side effects, etc., yellow to methods, test procedures, etc., and grey to historical details. [Pg.916]

In order to ensure quality control, USEPA has listed regulations, rules and guidance on approved analytical methods (test procedures) in the 40 CFR 136. This is especially... [Pg.24]

Leakage in fuel and hydraulic fluid systems of aircraft are viewed extremely seriously. Safety is a compelling factor that demands high quality from ruhher seals to he used in aircraft components. Hence, aircraft seals are manufactured with extra precision and extremely strict quality control measures for materials and their processing. Strict adherence to the specification of raw materials, processing methods, testing procedures, and dimensional standards are required. [Pg.37]

The use of the surface ultrasonic waves seems to be convenient for these purposes. However, this method has not found wide practical application. Peculiarities of excitation, propagation and registration of surface waves created before these time great difficulties for their application in automatic systems of duality testing. It is connected with the fact that the surface waves are weakened by soil on the surface itself In addition, the methods of testing by the surface waves do not yield to automation due to the difficulties of creation of the acoustic contact. In particular, a flow of contact liquid out of the zone of an acoustic line, presence of immersion liquid, availability of chink interval leads to the adsorption and reflection of waves on tlie front meniscus of a contact layer. The liquid for the acoustic contact must be located only in the places of contact, otherwise the influence on the amplitude will be uncontrolled. This phenomenon distorts the results of testing procedure. [Pg.876]

Attestation of the test procedure is realized with the aim to confirm both the correctness of the choice of method and NDT facilities and fullness of requirements included in the test procedure. Attestation ensures reliability of testing results with required accuracy. [Pg.961]

Several countries have developed their own standard test methods for cellular plastics, and the International Organization for Standards (ISO) Technical Committee on Plastics TC-61 has been developing international standards. Information concerning the test methods for any particular country or the ISO procedures can be obtained in the United States from the American National Standards Institute. The most complete set of test procedures for cellular plastics, and the most used of any in the world, is that developed by the ASTM these procedures are pubUshed in new editions each year (128). There have been several reviews of ASTM methods and others pertinent to cellular plastics (32,59,129—131). [Pg.408]

The test methods used by industry to determine if a sample of maleic anhydride is within specifications (165) ate ASTM methods D2930, D1493, and D3366. These methods describe procedures for the determination of maleic acid content, the crystallization point, and the color properties of the maleic anhydride sample, respectively. By quantitative deterrnination of these properties, a calculation of the overall purity of the maleic anhydride sample can be made. [Pg.459]

Overall, the test methods pubhshed by INDA (Table 4) continue to be the general tests used to characterize fabrics however, specific market apphcations often generate special test procedures to fiilfill unique needs. [Pg.170]

It is necessary to estabUsh a criterion for microbial death when considering a sterilization process. With respect to the individual cell, the irreversible cessation of all vital functions such as growth, reproduction, and in the case of vimses, inabiUty to attach and infect, is a most suitable criterion. On a practical level, it is necessary to estabUsh test criteria that permit a conclusion without having to observe individual microbial cells. The failure to reproduce in a suitable medium after incubation at optimum conditions for some acceptable time period is traditionally accepted as satisfactory proof of microbial death and, consequentiy, stetihty. The appHcation of such a testing method is, for practical purposes, however, not considered possible. The cultured article caimot be retrieved for subsequent use and the size of many items totally precludes practical culturing techniques. In order to design acceptable test procedures, the kinetics and thermodynamics of the sterilization process must be understood. [Pg.404]

Methods used for the tensile testing of single fibers and fibers taken from yams and tows are discussed in ASTM D3822 and D2101. Measurement equipment used in fiber tensile testing is described in ASTM D76. An overview of test procedures and their significance is also available (3,10). [Pg.454]

Solderability. Method 2003.5, MiUtary Standard—883C, Test Methods and Procedures for Microelectronics, Dept, of Defense, Washington, D.C., 1987. [Pg.236]

In an age of consumei activism and increasing international trade, test methods and procedures assume more and more importance. Generally accepted... [Pg.375]

Other New Methods. Because the values obtained are dependent on the conditions of measurement, standard test procedures are under review by ISO for determination of cold-water solubiUty of water-soluble dyes (38) determination of the solubiUty and solution stabiUty of water-soluble dyes (39) and determination of the electrolyte stabiUty of reactive dyes (40). [Pg.377]

The flash point is the lowest temperature at which a liquid gives off sufficient vapor to form an ignitable mixture with air near the surface of the liquid or within the vessel used. ASTM test methods include procedures using a closed cup (ASTM D56, ASTM DOS, and ASTM D3828), which is preferred, and an open cup (ASTM D92 and ASTM D1310). When several values are available, the lowest temperature is usually taken in order to assure safe operation of the process. [Pg.418]

Static performance measurements related to positioner/ac tuator operation are conformity, measured accuracy, hysteresis, dead baud, repeatability, and locked stem-pressure gain. Definitions and standardized test procedures for determining these measurements can be found in ISA-S75.13-1989, Method of Evaluating the Performance of Positioners with Analog Input Signals and Pneumatic Output . [Pg.783]

Commercial use of cell and tissue culture continues to expand. Improvement of organisms through recombinant nucleic acid techniques has become commonplace. Formerly, a few laboratories were well ahead of most others, but now the methods have been perfected for routine use. Another technique that is widely practiced is culturing of cells that excrete high concentrations of just one antibody protein. The specificity of antibodies and antigens is exploited in medical testing procedures using these pure monoclonal antibodies. [Pg.2135]

The instrumental analyzer procedure, EPA Method 3A, is commonly used for the determination of oxygen and carbon dioxide concentrations in emissions from stationary sources. An integrated continuous gas sample is extracted from the test location and a portion of the sample is conveyed to one or more instrumental analyzers for determination of O9 and CO9 gas concentrations (see Fig. 25-30). The sample gas is conditioned prior to introduction to the gas analyzer by removing particulate matter and moisture. Sampling is conducted at a constant rate for the entire test run. Performance specifications and test procedures are provided in the method to ensure reliable data. [Pg.2199]


See other pages where Methods/test procedures is mentioned: [Pg.19]    [Pg.485]    [Pg.504]    [Pg.19]    [Pg.485]    [Pg.504]    [Pg.26]    [Pg.156]    [Pg.156]    [Pg.669]    [Pg.751]    [Pg.70]    [Pg.178]    [Pg.208]    [Pg.311]    [Pg.18]    [Pg.131]    [Pg.522]    [Pg.543]    [Pg.153]    [Pg.453]    [Pg.458]    [Pg.228]    [Pg.461]    [Pg.311]    [Pg.317]    [Pg.579]    [Pg.7]    [Pg.153]    [Pg.227]    [Pg.290]    [Pg.23]    [Pg.377]    [Pg.2206]    [Pg.2311]   


SEARCH



Method procedure

Methodical procedures

Methods/test procedures analytical methodology

Methods/test procedures transfer

Testing Methods and Procedures for Industrial Floors

Testing procedures

© 2024 chempedia.info