Mass spectrometry reference materials

Resonance Ionization Mass Spectrometry Reference Material... [Pg.27]

Inductively coupled plasma—mass spectrometry (referred to in this book as ICP-MS), a technique for the elemental chemical characterization of virtually any material, evolved during the late 1990s into a mature analytical procedure. This technique has a variety of characteristics that make it uniquely suited for the solution of chemical analysis problems in many applications. These characteristics include the abihty to precisely identify and measure (quantitate) all elements in the periodic table including the often difficult to analyze refractory elements. In addition to this wide scope of elemental analysis, the technique has the inherent capabihty to perform these determinations in a multielement analysis mode, efficiendy providing comprehensive elemental compositional characterization. The technique also has the powerful ability to measure individual isotopes of the analyte elements, providing a capability that has many useful apphcations ranging from isotope dilution quantitation to stable isotope tracer studies. [Pg.3]

Secondary ion mass spectrometry (SIMS) is by far the most sensitive surface teclmique, but also the most difficult one to quantify. SIMS is very popular in materials research for making concentration depth profiles and chemical maps of the surface. For a more extensive treatment of SIMS the reader is referred to [3] and [14. 15 and 16]. The principle of SIMS is conceptually simple When a surface is exposed to a beam of ions... [Pg.1860]

Laser based mass spectrometric methods, such as laser ionization (LIMS) and laser ablation in combination with inductively coupled plasma mass spectrometry (LA-ICP-MS) are powerful analytical techniques for survey analysis of solid substances. To realize the analytical performances methods for the direct trace analysis of synthetic and natural crystals modification of a traditional analytical technique was necessary and suitable standard reference materials (SRM) were required. Recent developments allowed extending the range of analytical applications of LIMS and LA-ICP-MS will be presented and discussed. For example ... [Pg.425]

In the single-chamber type reactor (Fig. 4.1b) all three electrodes (catalyst-working (W), counter (C) and reference (R)), electrode are all in the same chamber and are all exposed to the reactants and products.1 3 In this case the counter and reference electrodes must be made from a catalytically inert (e.g. Au) material for otherwise the catalytic rate on them will obscure the measured (via gas-chromatography or mass-spectrometry, Fig. 4.2) rate on the catalyst-working electrode. [Pg.111]

The amounts of the standard isotopic species and the tracer isotopic species are represented by X and X for the sample and the reference material. The reference substance is chosen arbitrarily, but is a substance that is homogeneous, available in reasonably large amounts, and measurable using standard analytical techniques for measuring isotopes (generally mass spectrometry). For instance, a sample of ocean water known as Standard Mean Ocean Water (SMOW) is used as a reference for and 0. Calcium carbonate from the Peedee sedimentary formation in North Carolina, USA (PDB) is used for C. More information about using carbon isotopes is presented in Chapter 11. [Pg.91]

Moens L, Verreft P, Boonen S, Vanhaecke F and Dams R (1995) Solid sampling electrothermal vaporization for sample introduction in inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry. Spectrochim Acta 508 463-475. Mooijman KA, In t Veld PH, Hoekstra JA, Heisterkamp SH, Havelaar AH, Notermans SHW, Roberts D, Griepink B, Maier E (1992) Development of Microbiological Reference Materials. European Commission Report EUR 14375 EN, Community Bureau of Reference, Brussels. [Pg.46]

Chance DH, Adam BW, Smith SJ, Alexander JR, Hillman SL, Hannon WH (1999) Validation of accuracy-based amino acid reference materials in dried-blood spots by tandem mass spectrometry for newborn screening assays. Clin Chem 45 1269-1277. [Pg.148]

Principles and Characteristics Mass spectrometry can provide the accurate mass determination in a direct measurement mode. For a properly calibrated mass spectrometer the mass accuracy should be expected to be good to at least 0.1 Da. Accurate mass measurements can be made at any resolution (resolution matters only when separating masses). For polymer/additive deformulation the nominal molecular weight of an analyte, as determined with an accuracy of 0.1 Da from the mass spectrum, is generally insufficient to characterise the sample, in view of the small mass differences in commercial additives. With the thousands of additives, it is obvious that the same nominal mass often corresponds to quite a number of possible additive types, e.g. NPG dibenzoate, Tinuvin 312, Uvistat 247, Flexricin P-1, isobutylpalmitate and fumaric acid for m = 312 Da see also Table 6.7 for m = 268 Da. Accurate mass measurements are most often made in El mode, since the sensitivity is high, and reference mass peaks are readily available (using various fluorinated reference materials). Accurate mass measurements can also be made in Cl... [Pg.355]

Resolution does not affect the accuracy of the individual accurate mass measurements when no separation problem exists. When performing accurate mass measurements on a given component in a mixture, it may be necessary to raise the resolution of the mass spectrometer wherever possible. Atomic composition mass spectrometry (AC-MS) is a powerful technique for chemical structure identification or confirmation, which requires double-focusing magnetic, Fourier-transform ion-cyclotron resonance (FTICR) or else ToF-MS spectrometers, and use of a suitable reference material. The most common reference materials for accurate mass measurements are perfluorokerosene (PFK), perfluorotetrabutylamine (PFTBA) and decafluorotriph-enylphosphine (DFTPP). One of the difficulties of high-mass MS is the lack of suitable calibration standards. Reference inlets to the ion source facilitate exact mass measurement. When appropriately calibrated, ToF mass... [Pg.356]

Applications The application of the isotope dilution technique is especially useful in carrying out precise and accurate micro and trace analyses. The most accurate results in mass spectrometry are obtained if the isotope dilution technique is applied (RSDs better than 1 % in trace analysis). Therefore, application of IDMS is especially recommended for calibration of other analytical data, and for certification of standard reference materials. The technique also finds application in the field of isotope geology, and is used in the nuclear industry for quantitative isotope analysis. [Pg.661]

If we consider only a few of the general requirements for the ideal polymer/additive analysis techniques (e.g. no matrix interferences, quantitative), then it is obvious that the choice is much restricted. Elements of the ideal method might include LD and MS, with reference to CRMs. Laser desorption and REMPI-MS are moving closest to direct selective sampling tandem mass spectrometry is supreme in identification. Direct-probe MS may yield accurate masses and concentrations of the components contained in the polymeric material. Selective sample preparation, efficient separation, selective detection, mass spectrometry and chemometric deconvolution techniques are complementary rather than competitive techniques. For elemental analysis, LA-ICP-ToFMS scores high. [Pg.744]

The technique is referred to by several acronyms including LAMMA (Laser Microprobe Mass Analysis), LIMA (Laser Ionisation Mass Analysis), and LIMS (Laser Ionisation Mass Spectrometry). It provides a sensitive elemental and/or molecular detection capability which can be used for materials such as semiconductor devices, integrated optical components, alloys, ceramic composites as well as biological materials. The unique microanalytical capabilities that the technique provides in comparison with SIMS, AES and EPMA are that it provides a rapid, sensitive, elemental survey microanalysis, that it is able to analyse electrically insulating materials and that it has the potential for providing molecular or chemical bonding information from the analytical volume. [Pg.59]

In the following sections, the instrumental features of direct mass spectrometry based techniques (DI-MS, DE-MS and DTMS) are presented, followed by a discussion of some mass spectra of standard compounds and reference materials. Finally, a series of case studies related to the presence of resinous materials in archaeological findings and works of art are reported and discussed. [Pg.78]

In the present chapter, we first provide some general information concerning the chemistry of waxes and lipids currently encountered in various items from our cultural heritage and we detail the main protocols based on direct mass spectrometry that have been developed so far. We then discuss the mass spectra obtained by EI-MS on a range of reference substances and materials sampled from museum and archaeological artefacts. We then focus on the recent possibilities supplied by electrospray ionisation for the elucidation of the structure of biomarkers of beeswax and animal fats. [Pg.98]

Besides the well-established chromatographic/mass spectrometric or spectroscopic methods there is always a need for complementary methods for the study of organic materials from art objects. The application of laser desorption/ionisation mass spectrometry (LDI-MS) methods to such materials has been reported only sporadically [12, 45 48] however, it is apparently increasing in importance. After GALDI-MS had been applied to triterpenoid resins, as described in Section 5.2, this relatively simple method was evaluated for a wider range of binders and other organic substances used for the production or conservation of artwork. Reference substances as well as original samples from works of art were analysed. [Pg.144]

Nevertheless, the introduction of time-of-flight (ToF) analysers for SIMS analyses at the beginning of the 1980s, as well as the recent development of liquid ion sources delivering cluster projectiles now permit the analysis of organic materials with high sensitivity and selectivity. Moreover, thanks to its excellent lateral resolution (in the order of micrometres), and its minimal sample preparation, ToF-SIMS has become the reference technique for chemical imaging by mass spectrometry. [Pg.433]

Hollocher, K. and Ruiz, J. (1995). Major and trace-element determinations on NIST glass standard reference material-611, material-612, material-614, and material-1834 by inductively-coupled plasma-mass spectrometry. Geostandards Newsletter 19 27-34. [Pg.369]

In a subsequent study, Schnitzer and Spiteller [15] hydrolyzed each fraction with 2 M H2S04. After neutralization of the soluble materials, the latter were reduced with NaBH4 and then acetylated. The resulting acetates were analyzed by capillary gas chromatography/mass spectrometry, and identified by comparing their mass spectra with those of reference compounds of known structures and with literature data. Eighteen N-heterocyclics were identified. These compounds induded hydroxy-and oxy-indoles, quinolines, isoquinolines, aminobenzofurans, piperidines, pyrro-lines, and pyrrolidines. In addition, a number of benzylamines and nitriles were also identified. It is noteworthy that the N heterocyclics were isolated and identified without the use of pyrolysis. [Pg.122]

The primary and immediate need is for a trace metal reference material, but a certified reference material would provide even greater benefits. A technique based on isotope dilution with detection by inductively-coupled plasma mass spectrometry (ICP-MS) (Wu and Boyle, 1998) most clearly meets the traceability criteria required for a certified reference material. Although useful for iron and several other metals, isotope dilution is not possible for monoisotopic elements like cobalt, so other techniques must also be used. Indeed, it is advisable that several techniques be used to certify a trace metal reference material. [Pg.49]

At present, isotope-dilution mass spectrometry provides the best method to certify iron concentration in the recommended deep-water reference material (an expected iron concentration of approximately 0.7 nM) and to obtain an information value for iron in the recommended surface water reference material (an expected iron concentration of approximately 50 pM or less). [Pg.98]

Tai SS, Welch MJ. 2000. Determination of ll-nor-delta9-tetrahydrocannabinol-9-carboxylic acid in a urine-based standard reference material by isotope-dilution liquid chromatography-mass spectrometry with electrospray ionization. J Anal Toxicol 24 385. [Pg.175]


See other pages where Mass spectrometry reference materials is mentioned: [Pg.230]    [Pg.230]    [Pg.3]    [Pg.204]    [Pg.112]    [Pg.223]    [Pg.555]    [Pg.410]    [Pg.412]    [Pg.675]    [Pg.33]    [Pg.443]    [Pg.139]    [Pg.80]    [Pg.277]    [Pg.450]    [Pg.23]    [Pg.496]    [Pg.57]    [Pg.156]    [Pg.409]    [Pg.413]    [Pg.133]   