Knob control

Fig. 11. Analytical balance. The side-view diagram [Gram-atic (Mettler), Fisher Scientific Co.] illustrates a method of manipulation of analytical weights by knob controls as well as the technique of substitution weighing. Other details are supplied in the text. The use of such a balance, which requires little training, considerably shortens the time needed for analytical weighings. Fig. 11. Analytical balance. The side-view diagram [Gram-atic (Mettler), Fisher Scientific Co.] illustrates a method of manipulation of analytical weights by knob controls as well as the technique of substitution weighing. Other details are supplied in the text. The use of such a balance, which requires little training, considerably shortens the time needed for analytical weighings.
Blade Knobs. Control with a large straight blade across the center, use the blade to turn the... [Pg.920]

Clockwise rotation of control knob Counterclockwise rotation of control knob Control on right, vertical scale on left ... [Pg.470]

Do you have any switches in your work setting which are similar and nearby but control different functions How unsafe would it be to throw the wrong switch Many control panels are designed with this error in mind. Switches or knobs controlling incompatible fxmctions are not located in close proximity with one another and often look and feel distinctly different for quick visual and tactile discrimination. Thus, it might be useful to evaluate your work setting with regard to the need for different behaviors with similar descriptions. [Pg.60]

Raise, lower, and tilt. While in the operator s seat, the controls are to be used to tilt the mast forward, backward, up, and down. Check for slackness in the chain. Is the movement smooth The forks should be flat on the floor when looking at the condition of the chain. A thorough check of the chains should be completed with a gloved hand and rag for personal protection. All of the knobs, controls, handles, and markings should be in place. [Pg.188]

The oxygen used in the combustion is supplied by a small cylinder (120 Atm.) fitted with a pressure reduction valve, pressure gauge (to avoid the risk of the cylinder becoming exhausted during an actual determination) and fine control knob. It is important that the valve is kept free from oil or grease of any kind. In order to ensure the complete purity of the oxygen it is first passed through a purification train. [Pg.467]

Process-variable feedback for the controller is achieved by one of two methods. The process variable can (I) be measured and transmitted to the controller by using a separate measurement transmitter with a 0.2-I.0-bar (3-15-psi pneumatic output, or (2) be sensed directly by the controller, which contains the measurement sensor within its enclosure. Controllers with integral sensing elements are available that sense pressure, differential pressure, temperature, and level. Some controller designs have the set point adjustment knob in the controller, making set point adjustment a local and manual operation. Other types receive a set point from a remotely located pneumatic source, such as a manual air set regulator or another controller, to achieve set point adjustment. There are versions of the pneumatic controller that support the useful one-, two-, and three-mode combinations of proportional, integral, and derivative actions. Other options include auto/manual transfer stations, antireset windup circuitry, on/off control, and process-variable and set point indicators. [Pg.776]

A process waste heat boiler was damaged when the control operator inadvertently closed the cooling water valve when he intended to open it. The manual control knob turned in the opposite direction from most of the other valves in the plant—the L, cooling water valve was air to close—most control valves were air... [Pg.106]

In an inherently safer design all of the control knobs would jii the same way to open a valve. [Pg.106]

In a similar incident, a furnace damper was closed in error. It was operated pneumatically. There was no indication on the control knob to show which was the open position and which was the closed position. [Pg.99]

Small leaks from the glands of a carbon monoxide compressor were collected by a fan and discharged outside the building. A man working near the compressor was affected by carbon monoxide. Itwas then found that a damper in the fan delivery line was shut. There was no label or other indication to show whether the damper was closed or open. In a similar incident, a furnace damper was closed in error. It was operated pneumatically, and again there was no indication on the control knob to show which were the open and closed positions. [Pg.26]

Kerosene lamps have a flat cloth wick. Flame height is determined by the height of the wick, which is controlled by a ratchet knob. A glass chimney ensures both safety and a stable, draft-free flame. [Pg.691]

Cellulosic They are tough, transparent, hard or flexible natural polymers made from plant cellulose feedstock. With exposure to light, heat, weather and aging, they tend to dry out, deform, embrittle and lose gloss. Molding applications include tool handles, control knobs, eyeglass frames. Extrusion uses include blister packaging, toys, holiday decorations, etc. Cellulosic types, each with their specialty properties, include cellulose acetates (CAs), cellulose acetate butyrates (CABs), cellulose nitrates (CNs), cellulose propionate (CAPs), and ethyl celluloses (EC). [Pg.427]

It should be stressed that only those surfaces that actually come in contact with the sample need to be bio-compatible and the major parts of the valve can still be manufactured from stainless steel. The actual structure of the valve varies a little from one manufacturer to another but all are modifications of the basic sample valve shown in figure 13. The valve usually consists of five parts. Firstly there is the control knob or handle that allows the valve selector to be rotated and thus determines the load and sample positions. Secondly, a connecting device that communicates the rotary movement to the rotor. Thirdly the valve body that contains the different ports necessary to provide connections to the mobile phase supply, the column, the sample loop if one is available, the sample injection port and finally a port to waste. Then there is the rotor that actually selects the mode of operation of the valve and contains slots that can connect the alternate ports in the valve body to provide loading and sampling functions. Finally there is a pre-load assembly that furnishes an adequate pressure between the faces of the rotor and the valve body to ensure a leak tight seal. [Pg.140]

Example 62 If a manufacturing process involves two raw materials, each defined by three sets of specification limits, and four pieces of equipment with one control knob, then a complete validation protocol would ask for (Three settings Lo, Target, Hi) (2 materials 3 specs + 4 machines 1 control) = 3 = 59 000 experiments, even without repetitions. This product would never reach the market if one did not employ experience and scientific rationale to simplify development by testing only the presumed critical issues, say a total of three specification points for 3 = 27 experiments. [Pg.295]

The character and the degree of automation in chemical control may have been covered in the above treatment of semi-automatic or completely automatic, and of discontinuous or continuous analysis, but something more should be said about the means by which automation proper has been performed in recent times. Whereas in the past automated analysis involved the use of merely, mechanical robots, to-day s automation is preferably based on computerization in a way which can best be explained with a few specific examples. Adjustment knobs have been increasingly replaced with push-buttons that activate an enclosed fully dedicated microcomputer or microprocessor in line with the measuring instrument the term microcomputer is applicable if, apart from the microprocessor as the central processing unit (CPU), it contains additional, albeit limited, memory (e.g., 4K), control logics and input and output lines, by means of which it can act as satellite of a larger computer system (e.g., in laboratory computerization) if not enclosed, the microcomputer is called on-line. [Pg.327]

With their Models 763 and 764 microprocessor-controlled pH meter, Knick deliver and adapted Model 790 serial printer this yields in a simple way by means of an AC-synchronous clock and two adjustment knobs a hard copy of measurements at intervals of 2, 5, 10, 30 or 60 s or minutes printed out in a 32.5-mm rule of 12 positions on a small paper roll. [Pg.331]

A manual output adjust knob, in the center of the M-A transfer switch, varies the controller output signal in manual mode of operation. The knob is rotated clockwise to increase the signal and counterclockwise to decrease the signal. [Pg.157]

MAN. This position places the controller in the manual mode of operation. Controller output is now varied by adjusting the manual output adjust knob. This adjustment is indicated on the output meter. The deviation meter indicates any deviation between controlled variable and setpoint. [Pg.158]

KNOB protein, however, was shown to improve gene expression markedly (130-fold in HeLa cells). Additionally, it was shown that PEG could be conjugated to the surface of the nanospheres to prevent aggregation during lyophilization without a loss of bioactivity following one month in storage. The PEGylated particles, however, were cleared from mice at a slower rate than unmodified controls and were found to accumulate in the kidney and liver at 15 min after intravenous administration. There was no difference after one hour, however. [Pg.156]

We want to turn up the radio because it s noisy outside, and we want to hear what is broadcast. We therefore turn the volume knob toward loud . At its most basic, the volume control is a variable resistor, across which we pass a current from the battery, acting much like a kettle element. If we turn up the volume control then a larger current is allowed to flow, causing more energy to be produced by the resistor. As a listener, we hear a response because the sound from the speakers becomes louder. The speakers work harder. [Pg.3]

While the magnitude of the noise and the position of the volume knob are both variables, they represent different types, with one depending on the other. The volume control is a controlled variable because the listener dictates its position. The amount of noise is the observed variable because it only changes in response to variations in the controlled variable, and not before. [Pg.3]

Sample and scale image adjust. You use this knob to adjust the optics such that you see a split field in the eyepiece. The refractive index scale also moves when you turn this knob. The knob is often a dual control use the outer knob for a coarse adjustment and the inner knob as a fine adjustment. [Pg.223]

Observe how the voltage output of the regulated power supply can be controlled. To do this, touch the red multimeter lead to the output of the regulated power supply, either P42 or P43, and rotate the knobs of the potentiometers, first the coarse, then the fine. You should observe that this output can vary between -5 and +5 V. Record your observations and your comments in your notebook. [Pg.173]

Either one buffer solution, with a pH near that of the solution being tested, or two buffer solutions, with pH values that bracket that of the solution being tested, are usually used. When the pH electrode is dipped into a buffer solution during the standardization step, the pH reading on the meter is adjusted to the given pH using the standardize knob, or other control, on the meter. [Pg.541]

Insert the Blank solution in the nephelometer and adjust to zero reading of the scale by the aid of zero-control-knob,... [Pg.290]


See other pages where Knob control is mentioned: [Pg.137]    [Pg.287]    [Pg.289]    [Pg.77]    [Pg.187]    [Pg.115]    [Pg.353]    [Pg.137]    [Pg.287]    [Pg.289]    [Pg.77]    [Pg.187]    [Pg.115]    [Pg.353]    [Pg.115]    [Pg.65]    [Pg.155]    [Pg.770]    [Pg.161]    [Pg.75]    [Pg.153]    [Pg.11]    [Pg.16]    [Pg.27]    [Pg.188]    [Pg.34]    [Pg.137]    [Pg.3]    [Pg.208]    [Pg.269]   
See also in sourсe #XX -- [ Pg.137 ]