Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Connection devices

One has to consider that all connected devices must also withstand the maximum explosion overpressure. [Pg.2326]

The series capacitors tire connected in series with the power lines to provide reactive control to an individual load or to a power distribution or transmission system. They are therefore switched with the pow er lines and are thus permanently connected devices. [Pg.803]

Flange A connection device that allows two sections of duct or pipe to be bolted together. [Pg.1442]

It should be stressed that only those surfaces that actually come in contact with the sample need to be bio-compatible and the major parts of the valve can still be manufactured from stainless steel. The actual structure of the valve varies a little from one manufacturer to another but all are modifications of the basic sample valve shown in figure 13. The valve usually consists of five parts. Firstly there is the control knob or handle that allows the valve selector to be rotated and thus determines the load and sample positions. Secondly, a connecting device that communicates the rotary movement to the rotor. Thirdly the valve body that contains the different ports necessary to provide connections to the mobile phase supply, the column, the sample loop if one is available, the sample injection port and finally a port to waste. Then there is the rotor that actually selects the mode of operation of the valve and contains slots that can connect the alternate ports in the valve body to provide loading and sampling functions. Finally there is a pre-load assembly that furnishes an adequate pressure between the faces of the rotor and the valve body to ensure a leak tight seal. [Pg.140]

One has to consider that all connected devices must also withstand the maximum explosion overpressure. The NFPA 69 Standard, Explosion Prevention System, 1997 European Standard prEN 14460, Explosion Resistant Equipment, 2005 and Kirby and Siwek, Preventing Failures of Equipment Subject to Explosions, Chemical Engineering, June 23, 1986, provide excellent guidance on the practice of containment. [Pg.18]

This type of construction uses precast concrete walls with steel or concrete frames (Figure 4.2). The frame resists all vertical loads and precast shear walls resist lateral loads. Ductile connections for precast panels are an important consideration. Precast panels are made with embedded steel connection devices attached to the building frame by bolting or welding. The roof is usually a concrete slab on metal deck. The metal deck is attached to steel framing by studs or puddle welds. Tins type of construction can be economically designed to withstand blast loading on the order of 7 to 10 psi (48 to 69 kPa) side-on overpressure. [Pg.160]

Compressed Natural Gas Vehicle (NGV) Fueling Connection Devices, 1994 American National Standard/Canadian Gas Association Standard American Gas Association 8501 East Pleasant Valley Road Cleveland, Ohio 44131... [Pg.166]

In order to prevent the brine and the chlorine from penetrating into the denuder, partition plates (not reaching the bottom) which act as hydraulic seals are placed conveniently both in the rear and in the front connecting device. In the denuder, the amalgam is decomposed by water into caustic solution and hy-... [Pg.283]

The rear connection device is made of rubber-lined iron. It has a partition plate under which the amalgam flows into the denuder. Between the rear connecting device and the denuder two partition plates form a purification chamber with a rubber-plated iron lid. [Pg.285]

The bottom of the denuder slopes in the opposite direction to the tilt of the electrolyzer (tilt approx. 8 mm to a 1.000 mm length) to allow the mercury which reaches the denuder from the rear connecting device to gravitate to the... [Pg.285]

Softened water is supplied through a rotameter into the front connecting device between the partition plate and the mercury pump. It flows over the mercury level (washes the mercury) and enters the denuder through a pipe which is dipped under the level of the caustic solution. By this arrangement the escaping of hydrogen from the denuder is prevented. In the denuder water flows countercurrently to mercury and is withdrawn from the end of the denuder in form of a caustic solution. [Pg.286]

There are several categories of connectivity devices, but we are going to discuss the six most important and frequently used. They are... [Pg.332]

These connectivity devices have made it possible to lengthen the distance of the network to almost unlimited distances. [Pg.332]

In the last section of this chapter, you learned to differentiate between the different types of devices that connect to networks. These devices, called network connectivity devices, are very important to facilitating communications on a network. You learned how each device (including hubs, routers, bridges, brouters, etc.) works and how it relates to network communications. [Pg.335]

Which connectivity device transmits packets the fastest ... [Pg.337]

D. The hub provides the central connecting device in a star topology. All workstations must, therefore, connect to the hub in order to gain access to each other or any other resources present on the network. The one disadvantage of this is that the hub becomes a single point of failure. If the hub stops working, no one connected to the hub has network connectivity. [Pg.341]

The next most popular peripheral connection method is parallel. Parallel connections transfer data 8 bits at a time as opposed to 1 bit at a time (as serial connections do). The most common peripheral connected via a parallel connection is a printer. Hence, parallel ports are often called printer ports. Additionally, newer parallel ports can connect devices like scanners and Zip drives to computers. Unfortunately, this doesn t work as well as other types of connection methods such as USB work because the parallel connection wasn t designed for connecting devices other than printing devices. Parallel was only designed to connect one peripheral at a time. [Pg.657]

The Universal Serial Bus, or USB, is a relatively new connection device. Which of the following are characteristics of USB ... [Pg.680]

IComosDDevice refers to a collection (class IComosDCollection) of its connectors (method AllConnectors ()). The methods of class IComosDConnector are used to navigate (i) to the corresponding connector of the connected device (method ConnectedWithO), and (ii) to its own device (method owner ()), Phase 2 Interactively Exploring the TW Semantics... [Pg.581]


See other pages where Connection devices is mentioned: [Pg.464]    [Pg.119]    [Pg.8]    [Pg.626]    [Pg.395]    [Pg.603]    [Pg.12]    [Pg.491]    [Pg.224]    [Pg.232]    [Pg.282]    [Pg.282]    [Pg.283]    [Pg.283]    [Pg.286]    [Pg.288]    [Pg.289]    [Pg.303]    [Pg.332]    [Pg.332]    [Pg.333]    [Pg.334]    [Pg.336]    [Pg.814]    [Pg.819]    [Pg.838]    [Pg.858]    [Pg.327]    [Pg.95]    [Pg.703]   