Temperature, ionisation

Both emission and absorption spectra are affected in a complex way by variations in atomisation temperature. The means of excitation contributes to the complexity of the spectra. Thermal excitation by flames (1500-3000 K) only results in a limited number of lines and simple spectra. Higher temperatures increase the total atom population of the flame, and thus the sensitivity. With certain elements, however, the increase in atom population is more than offset by the loss of atoms as a result of ionisation. Temperature also determines the relative number of excited and unexcited atoms in a source. The number of unexcited atoms in a typical flame exceeds the number of excited ones by a factor of 103 to 1010 or more. At higher temperatures (up to 10 000 K), in plasmas and electrical discharges, more complex spectra result, owing to the excitation to more and higher levels, and contributions of ionised species. On the other hand, atomic absorption and atomic fluorescence spectrometry, which require excitation by absorption of UV/VIS radiation, mainly involve resonance transitions, and result in very simple spectra. [Pg.606]

Ramendik [16] pointed to the possibilities of the creation and development of theoretical foundations based on mathematical modelling in elemental mass spectrometry after the creation of a plasma. For laser plasma mass spectrometry of geological RMs and a quasi-equilibrium approach based on atomisation and ionisation temperatures without relying on reference RMs materials, he claims to be able to arrive at average uncertainties for 40 elements totalling 20% [17]. This may not be ideal but it is a suitable accuracy for solving many practical analytical problems. [Pg.39]

The Saha equation is only valid when the plasma is in (at least local) thermal equilibrium. The temperature resulting from the Saha equation is then the ionisation temperature. Under these conditions, the degree of ionisation can be calculated from the intensity of the atom and ion lines of the same element, I p and... [Pg.433]

Ionisation temperature This describes the equilibrium between atoms, ions and electrons in a plasma. When thermal equilibrium appHes, the Saha equation can be used to calculate the ionisation temperature from the intensity ratio of an ion and an atom line of the same element Another possibility is to calculate the ionisation temperature from the value that can be obtained from Stark broadening. [Pg.435]

Compared to TIMS, MC-ICP-MS has the potential to produce data of equal quality for a greater range of elements (including those with first ionisation potentials > 7 eV) as a result of the high ionisation temperature of its source (approximately 10 000 K vs approximately 2000 K for TIMS). Walder and Freedman were the first to describe the use of such an instrument and MC-ICP-MS has since established itself as a valuable addition to TIMS and ICP-quadrupole(Q)-MS techniques. [Pg.55]

The most accurate method of deriving from /igobs. is to use the equation k ih. = /i2obs.(i+/) the ionisation ratio of the compound under study being determined directly at the required acidity and temperature. In the cases where the temperature at which rates are measured is not 25 °C the way in which Aafb. depends upon acidity will be given correctly, but again there will remain the difficulty that the slope to be expected at this temperature other than 25 °C is not known. [Pg.152]

In applying this criterion, obs. must be compared with calc, for the same temperature. In general this entails knowledge of the temperature dependence of the relevant acidity function and of the ionisation constant. The latter factor has sometimes been allowed for (as in the calculation of calc, for the nitration of 2,4,6-trimethylpyridine in 98 % sulphuric acid at 80 °C) by using the approximate relationship, -d pKf) dT = (p, -o-9)/T. [Pg.154]

These equations, relating to oi,s, and E t,g to Egy, show that 3od can be calculated for a reaction proceeding through the equilibrium concentration of a free base if the thermodynamic quantities relating to the ionisation of the base, and the appropriate acidity function and its temperature coefficient are known (or alternatively, if the ionisation ratio and its temperature coefficient are known under the appropriate conditions for the base. )... [Pg.158]

When sulfuric acid is present in the mixed acids, the following ionisation reactions occur. These ionic reactions are rapid, and equiHbrium concentrations of NO2 are likely to be present at all times in the acid phase. NO2 concentrations depend mainly on the composition of the mixed acids but decrease to some extent as the temperature increases (3). [Pg.32]

The reactor coolant pH is controlled using lithium-7 hydroxide [72255-97-17, LiOH. Reactor coolant pH at 300°C, as a function of boric acid and lithium hydroxide concentrations, is shown in Figure 3 (4). A pure boric acid solution is only slightly more acidic than pure water, 5.6 at 300°C, because of the relatively low ionisation of boric acid at operating primary temperatures (see Boron COMPOUNDS). Thus the presence of lithium hydroxide, which has a much higher ionisation, increases the pH ca 1—2 units above that of pure water at operating temperatures. This leads to a reduction in corrosion rates of system materials (see Hydrogen-ION activity). [Pg.191]

Ionisation constants of ionisable compounds are give as pK values (published from the literature) and refer to the pKa values at room temperature ( 15 C to 25 C). The values at other temperatures are given as superscripts, e.g. pK for 25 C. Estimated values are entered as pKgjt (see Chapter 1, p. 7 for further information). [Pg.80]

Such vessels can also be baked at a temperature of several hundred degrees, to drive off any gas adsorbed on metal surfaces. The pumping function of an ion gauge was developed into efficient ionic pumps and turbomolecular pumps , supplemented by low-temperature traps and cryopumps. Finally, sputter-ion pumps, which rely on sorption processes initiated by ionised gas, were introduced. A vacuum of 10 "-10 Torr, true UHV, became routinely accessible in the late 1950s, and surface science could be launched. [Pg.406]

Ionisation constants for water and iweak electrolytes and variation with temperature... [Pg.1295]

B. Ionisation constants of weak electrolytes and their temperature variation ... [Pg.1326]

K is the equilibrium constant at a particular temperature and is usually known as the ionisation constant or dissociation constant. If 1 mole of the electrolyte is dissolved in Vlitres of solution (V = l/c, where c is the concentration in moles per litre), and if a is the degree of ionisation at equilibrium, then the amount of un-ionised electrolyte will be (1 — a) moles, and the amount of each of the ions will be a moles. The concentration of un-ionised acetic acid will therefore be (1 — a)/ V, and the concentration of each of the ions cl/V. Substituting in the equilibrium equation, we obtain the expression ... [Pg.31]

The hydrolysis constant is thus related to the ionic product of water and the ionisation constant of the acid. Since Ka varies slightly and Kw varies considerably with temperature, Kh and consequently the degree of hydrolysis will be largely influenced by changes of temperature. [Pg.43]

In all calibration operations, the apparatus to be calibrated must be carefully cleaned and allowed to stand adjacent to the balance which is to be employed, together with a supply of distilled or de-ionised water, so that they assume the temperature of the room. Flasks will also need to be dried, and this can be accomplished by rinsing twice with a little acetone and then blowing a current of air through the flask to remove the acetone. [Pg.88]

Ion exchange column. Prepare the Chelex-100 resin (100- 500 mesh) by digesting it with excess (about 2-3 bed-volumes) of 2M nitric acid at room temperature. Repeat this process twice and then transfer sufficient resin to fill a 1.0 cm diameter column to a depth of 8 cm. Wash the resin column with several bed-volumes of de-ionised water. [Pg.213]

Procedure. Allow the whole of the sample solution (1 L) to flow through the resin column at a rate not exceeding 5 mL min . Wash the column with 250 mL of de-ionised water and reject the washings. Elute the copper(II) ions with 30 mL of 2M nitric acid, place the eluate in a small conical flask (lOOmL, preferably silica) and evaporate carefully to dryness on a hotplate (use a low temperature setting). Dissolve the residue in 1 mL of 0.1 M nitric acid introduced by pipette and then add 9 mL of acetone. Determine copper in the resulting solution using an atomic absorption spectrophotometer which has been calibrated using the standard copper(II) solutions. [Pg.213]

Ionisation detectors. An important characteristic of the common carrier gases is that they behave as perfect insulators at normal temperatures and pressures. The increased conductivity due to the presence of a few charged molecules in the effluent from the column thus provides the high sensitivity which is a feature of the ionisation based detectors. Ionisation detectors in current use include the flame ionisation detector (FID), thermionic ionisation detector (TID), photoionisation detector (PID) and electron capture detector (ECD) each, of course, employing a different method to generate an ion current. The two most widely used ionisation detectors are, however, the FID and ECD and these are described below. [Pg.242]

The most common selective detectors in use generally respond to the presence of a characteristic element or group in the eluted compound. This is well illustrated by the thermionic ionisation detector (TID) which is essentially a flame ionisation detector giving a selective response to phosphorus- and/or nitrogen-containing compounds. Typically the TID contains an electrically heated rubidium silicate bead situated a few millimetres above the detector jet tip and below the collector electrode. The temperature of the bead is maintained... [Pg.243]

Buffer solution. Add 55 mL of concentrated hydrochloric acid to 400 mL de-ionised water and mix thoroughly. Slowly pour 310 mL of redistilled monoethanolamine with stirring into the mixture and cool to room temperature (Note 2). Titrate 50.0 mL of the standard magnesium chloride solution with standard (0.01M) EDTA solution using 1 mL of the monoethanolamine-hydrochloric acid solution as the buffer and solochrome black as the indicator. Add 50.0 mL of the magnesium chloride solution to the volume of EDTA solution required to complex the magnesium exactly (as determined in the last titration), pour the mixture into the monoethanolamine-hydrochloric acid solution, and mix well. Dilute to 1 litre (Note 3). [Pg.330]

Ethanol production in the fermentation process was detected with gas chromatography, HP 5890 series II (Hewlett-Packard, Avondale, PA, USA) equipped with a flame ionisation detector (FID) and GC column Porapak QS (Alltech Associates Inc., Deerfield, IL, USA) 100/120 mesh. The oven and detector temperature were 175 and 185 °C, respectively. Nitrogen gas was used as a carrier. Isopropanol was used as an internal standard. [Pg.211]

Ethanol concentration in the fermentation broth is determined by using gas chromatography (HP 5890 series II with HP Chemstation data processing software, Hewlett-Packard, Avondale, PA) with a Poropak Q Column, and a Hewlett-Packard model 3380A integrator. A flame ionisation detector (FID) is used to determine ethanol. The oven temperature is maintained at 180 °C, and the injector and detector temperature are maintained at 240 °C. The sample taken from the fermentation media has to be filtered and any internal standard must be added for analysis based on internal standard methods otherwise, the area under the peak must be compared with known standard samples for calculation based on external standard methods. [Pg.257]


See other pages where Temperature, ionisation is mentioned: [Pg.111]    [Pg.45]    [Pg.111]    [Pg.45]    [Pg.354]    [Pg.438]    [Pg.254]    [Pg.418]    [Pg.54]    [Pg.28]    [Pg.293]    [Pg.117]    [Pg.510]    [Pg.54]    [Pg.278]    [Pg.232]    [Pg.502]    [Pg.443]    [Pg.444]    [Pg.866]    [Pg.88]    [Pg.773]    [Pg.793]    [Pg.864]    [Pg.309]    [Pg.373]   
See also in sourсe #XX -- [ Pg.435 ]