Copper standard

To convert to cal, divide by 4.184. To convert mPa to )J.m Hg, divide by 133.3. lACS = International Annealed Copper Standard. Pure copper Table 2. Corrosion of Niobium Metal = 100%. ... [Pg.21]

To convert MPa to psi, multiply by 145. lACS = International Annealed Copper Standard. ... [Pg.71]

The specific resistance of the International Annealed Copper Standard copper is reported as 1.682 x 10 H at 20°C, which is defined as a... [Pg.211]

Electrical—Thermal Conductivities. Electrical conductivities of alloys (Table 5) are often expressed as a percentage relative to an International Annealed Copper Standard (lACS), ie, units of % lACS, where the value of 100 % lACS is assigned to pure copper having a measured resistivity value of 0.017241 Q mm /m. The measurement of resistivity and its conversion to % lACS is covered under ASTM B193 (8). [Pg.222]

A major concern surrounding isotope data obtained during analysis is the measurement error associated with mass fractionation within the instrument owing to variations in operating conditions (e.g. Marechal etat. 1999). In order to constrain the errors associated with copper isotope analyses on our instrument, we compared all of the copper ratios to the NIST 976 copper standard (eq. 1) using standard-sample-standard bracketing. The 2a error for the variation of the standard for eight analytical sessions was observed to be +... [Pg.252]

Prepare a series of copper standards ranging from 0 to 100 ng mF in 2% nitric acid. [Pg.172]

To convert MPa to psi, multiply by 145. IACS = International Annealed Copper Standard. Precipitation heat treatment of 3 h at 315°C. Precipitation heat treatment of 2 h at 315°C. Precipitation heat treatment of 3 h at 340°C. f ... [Pg.71]

The electrical conductivity of beryllium is dependent upon both temperature and metal punty. It vanes at room temperature between + 42 7 (International Annealed Copper Standard). Electrical resistivity of 4.266 10 3 ohm m at 25°C has been reported. [Pg.195]

Small amounts of zinc, lead, iron, antimony, and phosphorus also present. b International Annealed Copper Standard. c Ree-cutting phosphor bronze. [Pg.1618]

Figure 9. Analysis of a surface stain on copper showing copper sulfide contamination (a) stained copper (b) "clean" copper standard. Figure 9. Analysis of a surface stain on copper showing copper sulfide contamination (a) stained copper (b) "clean" copper standard.
Find activity of copper in the alloy of the solidus composition, relative to the pure solid copper standard state. The standard free energy of fusion of copper is given by... [Pg.156]

Bis(l-phenyl-l,3-butanediono) copper(II) NBS No. 1080, ca. 16.5% copper, for preparation of organo-copper standard solution. [Pg.156]

Only the wavelength intensities were used in this analysis since the concentrations generated by the program are semiquantitative in that the concentration is an average of the spectra scanned for each element. Copper standards were prepared, arced, and scanned along with the copper samples. Calibration curves were drawn for each analytical standard. The wavelength intensities of the sample spectra were compared with these curves and the quantitative trace element composition derived. [Pg.337]

Temp coeff, at 20°, yS -cm/°C Electrical conductivity, at 20° annealed copper (standard) mass % vol %... [Pg.23]

The reference materials for calibration of the spectrophotometer for flame atomic absorption analysis were prepared from the copper standard solution by its dilution with nitric acid 1% solu-... [Pg.11]

Shortly before use, make up 100 ml of copper standard solution I to 1000 ml with water. 1 ml contains 0.002 mg Cu2+. [Pg.374]

To establish the calibration curves, use copper standard solution II to prepare series containing concentrations of 0.005 - 0.10 mg Cu2+/l and 0.10 - 0.50 mg Cu2+/1. Then proceed as described under "Determination . [Pg.374]

Conductivity at 20°C (% of International Annealed Copper standard) Resistivity at 20°C, ohm cm Resistivity-temperature coefhcient, (°C) ... [Pg.732]

Cu is used as the technical standard for the conductivity of metals and alloys. The International Annealed Copper Standard (lACS) is defined by a Cu wire, 1 m long and weighing 0.1kg, the resistance of which is 0.15327 at 20 °C. Accordingly, a conductivity of 100% lACS = 58.00MSm (ormS2 mm ), which corresponds to a resistivity of 1.7243793 ( xf2 cm). The electrical conductivity is specifically and strongly dependent on the kind and concentration of impurities (Fig. 3.1-130). [Pg.296]

CVD chemical vapour deposition lACS International Annealed Copper Standard... [Pg.1140]


See other pages where Copper standard is mentioned: [Pg.272]    [Pg.566]    [Pg.190]    [Pg.92]    [Pg.385]    [Pg.221]    [Pg.241]    [Pg.916]    [Pg.918]    [Pg.22]    [Pg.172]    [Pg.385]    [Pg.201]    [Pg.289]    [Pg.186]    [Pg.73]    [Pg.341]    [Pg.345]    [Pg.560]    [Pg.40]    [Pg.279]    [Pg.567]    [Pg.92]    [Pg.88]    [Pg.145]    [Pg.146]    [Pg.374]    [Pg.374]    [Pg.47]   
See also in sourсe #XX -- [ Pg.925 ]




SEARCH



Copper complexes standard reduction potentials

Copper standard electrode potential

Copper standard reduction potentials

Copper standardization with thiosulfate

International Annealed Copper Standard