Gas fluorescence

The prism at the outlet of the laser serves to separate the laser emission of the gas fluorescence and allows for a clean excitation of the sample. For excitation using solid-state lasers, this element is dispensable. The lens (element 5) collects the fluorescent signal and focuses on the aperture of the monochromator. The filter is used to eliminate excitation that is spread over the surface of the sample. The optical chopper serves to modulate the light at a defined frequency, which serves as reference for the lock-in amplifier. A data acquisition system controls the pace of the monochromator and reads the signal of the lock-in, generating the sample s emission spectrum. [Pg.704]

Figure 11. Comparison of SH A2X — X2 fluorescence and synthetic emission spectra for a CtHf-Or-Nt (2 2.5 10) flame with 0.5% H,S added to the unburnt gas. Fluorescence excited at 323.76 nm. Figure 11. Comparison of SH A2X — X2 fluorescence and synthetic emission spectra for a CtHf-Or-Nt (2 2.5 10) flame with 0.5% H,S added to the unburnt gas. Fluorescence excited at 323.76 nm.
The regions in which PuFe shows continuous absorption as well as the 5f state energies shown in Figure 1 are based primarily on Steindler and Gunther s measurements (16). For a current theoretical interpretation of the 5f state structure of PuFe see J. Blaise et al. (this volume). The first dissociation limit of PuFe is crudely estimated based on the extremely small PuFe gas fluorescence photon yield but long fluorescence lifetime we have found (see below). In addition, the fact that PuFe is a better fluorinating agent than molecular fluorine... [Pg.157]

A typical emission trace for XeF is shown in Figure 5a, for 500 Torr of xenon and 0.50 Torr of SF. This curve has several components a X-ray signal, dimer rare gas fluorescence and ionic recombination formed exciplex fluorescence. The X-ray signal followed the time profile of the 3 ns. electron pulse, and was typically only a few percent of the total emission signal. The first emission peak was also observed in irradiated pure xenon, at all wavelengths across and outside the XeF emission spectrum, and was therefore assigned to the broad xenon dimer, Xe2 fluorescence. The decay of the dimer fluorescence was typically complete within several hundred nanoseconds, and its intensity varied greatly with the xenon pressure. The second peak in the emission curve was dose-dependent, and only observed across the known XeF ... [Pg.127]

The number of photons emitted from an irradiated gas sample were obtained by summing the integrated emission over the exciplex spectrum, and then correcting for the dimer rare gas fluorescence and X-rays. The irradiation energy deposited was measured using conventional ozone dosimetry [69], performed under identical conditions to the emission measurements. [Pg.136]

Tunable visible and ultraviolet lasers were available well before tunable infrared and far-infrared lasers. There are many complexes that contain monomers with visible and near-UV spectra. The earliest experiments to give detailed dynamical infonnation on complexes were in fact those of Smalley et al [22], who observed laser-induced fluorescence (LIF) spectra of He-l2 complexes. They excited the complex in the I2 B <—A band, and were able to produce excited-state complexes containing 5-state I2 in a wide range of vibrational states. From line w idths and dispersed fluorescence spectra, they were able to study the rates and pathways of dissociation. Such work was subsequently extended to many other systems, including the rare gas-Cl2 systems, and has given quite detailed infonnation on potential energy surfaces [231. [Pg.2447]

Despite their importance, gas chromatography and liquid chromatography cannot be used to separate and analyze all types of samples. Gas chromatography, particularly when using capillary columns, provides for rapid separations with excellent resolution. Its application, however, is limited to volatile analytes or those analytes that can be made volatile by a suitable derivatization. Liquid chromatography can be used to separate a wider array of solutes however, the most commonly used detectors (UV, fluorescence, and electrochemical) do not respond as universally as the flame ionization detector commonly used in gas chromatography. [Pg.596]

Figure 8.28 shows how the X-rays fall on the solid or liquid sample which then emits X-ray fluorescence in the region 0.2-20 A. The fluorescence is dispersed by a flat crystal, often of lithium fluoride, which acts as a diffraction grating (rather like the quartz crystal in the X-ray monochromator in Figure 8.3). The fluorescence may be detected by a scintillation counter, a semiconductor detector or a gas flow proportional detector in which the X-rays ionize a gas such as argon and the resulting ions are counted. Figure 8.28 shows how the X-rays fall on the solid or liquid sample which then emits X-ray fluorescence in the region 0.2-20 A. The fluorescence is dispersed by a flat crystal, often of lithium fluoride, which acts as a diffraction grating (rather like the quartz crystal in the X-ray monochromator in Figure 8.3). The fluorescence may be detected by a scintillation counter, a semiconductor detector or a gas flow proportional detector in which the X-rays ionize a gas such as argon and the resulting ions are counted.
Figure 9.46 shows an example of a fluorescence excitation spectmm of hydrogen bonded dimers of x-tetrazine (1,2,4,5-tetraazabenzene). The pressure of x-tetrazine seeded into helium carrier gas at 4 atm pressure was about 0.001 atm. Expansion was through a 100 pm diameter nozzle. A high-resolution (0.005 cm ) dye laser crossed the supersonic jet 5 mm downstream from the nozzle. [Pg.397]

The fluorescence excifafion spectra in Figures 9.47(a) and 9.47(b) show the Ojj bands of the A B2 X Ai system of aniline (see Figure 5.19) and the aniline Ar complex in a skimmed supersonic jet of aniline seeded into the argon carrier gas. [Pg.398]

Polyester composition can be determined by hydrolytic depolymerization followed by gas chromatography (28) to analyze for monomers, comonomers, oligomers, and other components including side-reaction products (ie, DEG, vinyl groups, aldehydes), plasticizers, and finishes. Mass spectroscopy and infrared spectroscopy can provide valuable composition information, including end group analysis (47,101,102). X-ray fluorescence is commonly used to determine metals content of polymers, from sources including catalysts, delusterants, or tracer materials added for fiber identification purposes (28,102,103). [Pg.332]

Several gas-Hquid chromatographic procedures, using electron-capture detectors after suitable derivatization of the aminophenol isomers, have been cited for the deterrnination of impurities within products and their detection within environmental and wastewater samples (110,111). Modem high pressure Hquid chromatographic separation techniques employing fluorescence (112) and electrochemical (113) detectors in the 0.01 pg range have been described and should meet the needs of most analytical problems (114,115). [Pg.312]

Chromatographic methods, notably hplc, are available for the simultaneous deterrnination of ascorbic acid as weU as dehydroascorbic acid. Some of these methods result in the separation of ascorbic acid from its isomers, eg, erythorbic acid and oxidation products such as diketogulonic acid. Detection has been by fluorescence, uv absorption, or electrochemical methods (83—85). Polarographic methods have been used because of their accuracy and their ease of operation. Ion exclusion (86) and ion suppression (87) chromatography methods have recently been reported. Other methods for ascorbic acid deterrnination include enzymatic, spectroscopic, paper, thin layer, and gas chromatographic methods. ExceUent reviews of these methods have been pubHshed (73,88,89). [Pg.17]

Diels-Alder reactions, 4, 842 flash vapour phase pyrolysis, 4, 846 reactions with 6-dimethylaminofuKenov, 4, 844 reactions with JV,n-diphenylnitrone, 4, 841 reactions with mesitonitrile oxide, 4, 841 structure, 4, 715, 725 synthesis, 4, 725, 767-769, 930 theoretical methods, 4, 3 tricarbonyl iron complexes, 4, 847 dipole moments, 4, 716 n-directing effect, 4, 44 2,5-disubstituted synthesis, 4, 116-117 from l,3-dithiolylium-4-olates, 6, 826 electrocyclization, 4, 748-750 electron bombardment, 4, 739 electronic deformation, 4, 722-723 electronic structure, 4, 715 electrophilic substitution, 4, 43, 44, 717-719, 751 directing effects, 4, 752-753 fluorescence spectra, 4, 735-736 fluorinated derivatives, 4, 679 H NMR, 4, 731 Friedel-Crafts acylation, 4, 777 with fused six-membered heterocyclic rings, 4, 973-1036 fused small rings structure, 4, 720-721 gas phase UV spectrum, 4, 734 H NMR, 4, 7, 728-731, 939 solvent effects, 4, 730 substituent constants, 4, 731 halo... [Pg.894]

EPA Method 6C is the instrumental analyzer procedure used to determine sulfur dioxide emissions from stationaiy sources (see Fig. 25-30). An integrated continuous gas sample is extracted from the test location, and a portion of the sample is conveyed to an instrumental analyzer for determination of SO9 gas concentration using an ultraviolet ( UV), nondispersive infrared (NDIR), or fluorescence analyzer. The sample gas is conditioned prior to introduction to the gas analyzer by removing particulate matter and moisture. Sampling is conducted at a constant rate for the entire test rim. [Pg.2200]

At X-ray fluorescence analysis (XRF) of samples of the limited weight is perspective to prepare for specimens as polymeric films on a basis of methylcellulose [1]. By the example of definition of heavy metals in film specimens have studied dependence of intensity of X-ray radiation from their chemical compound, surface density (P ) and the size (D) particles of the powder introduced to polymer. Have theoretically established, that the basic source of an error of results XRF is dependence of intensity (F) analytical lines of determined elements from a specimen. Thus the best account of variations P provides a method of the internal standard at change P from 2 up to 6 mg/sm the coefficient of variation describing an error of definition Mo, Zn, Cu, Co, Fe and Mn in a method of the direct external standard, reaches 40 %, and at use of a method of the internal standard (an element of comparison Ga) value does not exceed 2,2 %. Experiment within the limits of a casual error (V changes from 2,9 up to 7,4 %) has confirmed theoretical conclusions. [Pg.104]

The continuous methods combine sample collection and the measurement technique in one automated process. The measurement methods used for continuous analyzers include conductometric, colorimetric, coulometric, and amperometric techniques for the determination of SO2 collected in a liquid medium (7). Other continuous methods utilize physicochemical techniques for detection of SO2 in a gas stream. These include flame photometric detection (described earlier) and fluorescence spectroscopy (8). Instruments based on all of these principles are available which meet standard performance specifications. [Pg.201]

While some video display screens such as liquid crystal, gas plasma or vacuum fluorescent displays do not present the same charged screen hazards as CRTs, this does not imply that they are safe for use in hazardous locations. This requires special design and certification for use with a given flammable atmosphere. Non-certified equipment used in locations classified as hazardous under Article 500 of NFPA 70 National Electrical Code require a purged or pressurized enclosure to control ignition hazards as described in NFPA 496 Standard for Purged and Pressurized Enclosures for Electrical Equipment. The screen in this case is located behind a window in the enclosure. [Pg.165]


See other pages where Gas fluorescence is mentioned: [Pg.160]    [Pg.294]    [Pg.129]    [Pg.1198]    [Pg.181]    [Pg.160]    [Pg.294]    [Pg.129]    [Pg.1198]    [Pg.181]    [Pg.271]    [Pg.299]    [Pg.799]    [Pg.2475]    [Pg.43]    [Pg.643]    [Pg.29]    [Pg.38]    [Pg.118]    [Pg.374]    [Pg.377]    [Pg.401]    [Pg.276]    [Pg.262]    [Pg.388]    [Pg.114]    [Pg.395]    [Pg.62]    [Pg.71]    [Pg.91]    [Pg.418]    [Pg.355]    [Pg.208]    [Pg.412]    [Pg.313]    [Pg.341]   