Analytical trace analysis

As in fluorescence, phosphorescence signals depend upon both structural and environmental factors. Under appropriate experimental conditions, the intensity of the phosphorescent emission measured is linearly related to the concentration of the phosphor. This relationship, which constitutes the theoretical basis of quantitative phosphorescence analysis, is very similar to that obtained for fluorescence, except that the efficiency of intersystem crossing , which populates the triplet, should also be taken into account. Therefore, at very low concentrations of the analyte (trace analysis), the basic equation is... [Pg.3694]

Gairns, T. Rogers, W. M. Acceptable Analytical Data for Trace Analysis, Anal. Chem. 1993, 55, 54A-57A. [Pg.724]

Limits of detection become a problem in capillary electrophoresis because the amounts of analyte that can be loaded into a capillary are extremely small. In a 20 p.m capillary, for example, there is 0.03 P-L/cm capillary length. This is 1/100 to 1/1000 of the volume typically loaded onto polyacrylamide or agarose gels. For trace analysis, a very small number of molecules may actually exist in the capillary after loading. To detect these small amounts of components, some on-line detectors have been developed which use conductivity, laser Doppler effects, or narrowly focused lasers (qv) to detect either absorbance or duorescence (47,48). The conductivity detector claims detection limits down to lO molecules. The laser absorbance detector has been used to measure some of the components in a single human cell (see Trace AND RESIDUE ANALYSIS). [Pg.183]

Laser based mass spectrometric methods, such as laser ionization (LIMS) and laser ablation in combination with inductively coupled plasma mass spectrometry (LA-ICP-MS) are powerful analytical techniques for survey analysis of solid substances. To realize the analytical performances methods for the direct trace analysis of synthetic and natural crystals modification of a traditional analytical technique was necessary and suitable standard reference materials (SRM) were required. Recent developments allowed extending the range of analytical applications of LIMS and LA-ICP-MS will be presented and discussed. For example ... [Pg.425]

Reliable quantification is based on peak-search software that combines peak location, peak identification, and element deduction. Element deduction means that, for unambiguous detection, at least two of the principal peaks must be detected for each analyte of interest. In trace analysis, only the strongest peaks can be detected and special attention must be paid to interfering satellites and spurious peaks. [Pg.188]

Trace enrichment and sample clean-up are probably the most important applications of LC-LC separation methods. The interest in these LC-LC techniques has increased rapidly in recent years, particularly in environmental analysis and clean-up and/or trace analysis in biological matrices which demands accurate determinations of compounds at very low concentration levels present in complex matrices (12-24). Both sample clean-up and trace enrichment are frequently employed in the same LC-LC scheme of course, if the concentration of the analytes of interest are Sufficient for detection then only the removal of interfering substances by sample clean-up is necessary for analysis. [Pg.117]

E. A. Hogendoorn, E. Dijkman, B. Baumann, C. Hidalgo, J. V. Sancho and E. Hernandez, Strategies in using analytical restricted access media columns for the removal of humic acid interferences in the trace analysis of acidic herbicides in water... [Pg.373]

Throughout this book the use of a number of standard analytical samples is recommended in order that practical experience may be gained on substances of known composition. In addition, standard reference materials of environmental samples for trace analysis are used for calibration standards, and pure organic compounds are employed as standard materials for elemental analysis. [Pg.830]

We inferred that these properties might be exploited in a series of unique derivatizing reagents designed specifically for trace analysis of organic compounds using HPLC separation and fluorescence detection. The use of these pyridones for the analytical purposes reported here is based on their acidic properties. Treatment of a lH-2-pyridone with a base converts the pyridone to its salt. [Pg.207]

LGC - VAM Publications (i) The Fitness for Purpose of Analytical Methods, A Laboratory Guide to Method Validation and Related Topics, (2) Practical Statistics for the Analytical Scientist A Bench Guide By TJ Farrant, (3) Trace Analysis A structured Approach to Obtaining Reliable Results By E Pritchard, (4) Quantifying Uncertainty in Analytical Measurement, and (5) Quality in the Analytical Chemistry Laboratory. LGC/RSC Publications, London, England. [Pg.255]

Volatile analytes. As residue analysis is also trace analysis in the lower ppm (mg kg ) to ppb ( ug kg ) range, concentration steps usually involve evaporation of solvents (sometimes with traces of water present) to near dryness. The volatility of analytes can be deduced from their elution temperatures in GC, and thus whenever an analyte elutes from a nonpolar GC phase of film thickness <0.25 qm below approximately 150 °C, losses due to co-evaporation during concentration by the rotary evaporator or by a stream of nitrogen need to be avoided. [Pg.59]

A final point is the value of earlier (old) validation data for actual measurements. In a study about the source of error in trace analysis, Horwitz et al. showed that systematic errors are rare and the majority of errors are random. In other words, the performance of a laboratory will vary with time, because time is related to other instruments, staff, chemicals, etc., and these are the main sources of performance variation. Subsequently, actual performance verification data must be generated to establish method performance for all analytes and matrices for which results will be reported. [Pg.131]

Other extraction methods use an SPE disk and SPME. The analysis of water samples using SPE disks (SPE-Cig disk) was performed according to the methodology described by Albanis and Hela. Generally, the SPME method is a more reliable technique than SPE for trace analysis that can shorten the analytical procedure. [Pg.1142]

A disadvantage of supercritical fluids for extraction is that most common fluids used for extraction (carbon dioxide, nitrous oxide, sulfur hexafluoride, etc.) are weak solvents, limiting the polarity and molecular weight range of analytes that can be efficiently extracted. Also, for trace analysis the availability of fluids of adeguate ptirity may be a problem. [Pg.409]

The halogen-containing alkylsilyl derivatives have never enjoyed extensive popularity for trace analysis. There are several probable reasons for this modest sensitivity difficulties in c x)veniently separating derivatives from excess reagent Interferences in the separation of low molecular weight analytes by reagent impurities and reaction byproducts (particularly the disiloxanes formed by reaction of the reagents with water) and poor hydrolytic stat Ky of some derivatives. In the case of the... [Pg.942]

In LIF detection systems, excitation power may be increased up to six orders of magnitude compared to CF detection. Most LC-LIF detection concerns under-ivatised polynuclear aromatic hydrocarbons (PAHs) and fluorescing dyes (e.g. polymethines). Because only a limited number of analytes possess native fluorescence, derivatisation of the analyte before detection is normally required in trace analysis of organic solutes by means of LIF detection. LIF detection in HPLC was reviewed... [Pg.242]

Very high sensitivity trace analysis (fg-pg analyte quantities)... [Pg.394]

Modifiers can be used very effectively in on-line SFE-GC to determine the concentration levels of the respective analytes. This presents an advantage in terms of the use of modifiers in SFE, since they appear as solvent peaks in GC separations and do not interfere with the target analyte determination. Although online SFE-GC is a simple technique, its applicability to real-life samples is limited compared to off-line SFE-GC. As a result, on-line SFE-GC requires suitable sample selection and appropriate setting of extraction conditions. If the goal is to determine the profile or matrix composition of a sample, it is required to use the fluid at the maximum solubility. For trace analysis it is best to choose a condition that separates the analytes from the matrix without interference. However, present SFE-GC techniques are not useful for samples... [Pg.435]

Trace analysis is particularly attractive for SFE-HPLC since quantitative transfer of all analytes extracted to the chromatographic system becomes possible. At present, on-line SFE-HPLC appears to be feasible for qualitative analysis only quantitation is difficult due to possible pump and detector precision problems. Sample size restrictions also appear to be another significant barrier to using on-line SFE-HPLC for quantitative analysis of real samples. On-line SFE-HPLC has therefore not proven to be a very popular hyphenated sample preparatory/separation technique. Although online SFE-HPLC has not been quantitatively feasible, SFE is quite useful for quantitative determination of those analytes that must be analysed by off-line HPLC, and should not be ruled out when considering sample preparatory techniques. In most cases, all of the disadvantages mentioned with the on-line technique (Table 7.15) are eliminated. On- and off-line SFE-HPLC were reviewed [24,128]. [Pg.445]

Trends in element analysis are multi-element (survey) analysis, lower concentration levels, micro/local element analysis and speciation (coupling with chromatography). An overview of the determination of elements in polymeric materials is available [7], Reviews on sample preparation for trace analysis are given in refs [8-10]. Quality assurance of analytical data in routine elemental analysis has been discussed [11], Organic analysis is obviously much more requested in relation to polymer/additive matrices than elemental analysis. [Pg.591]

Modem trace analysis is interested in detailed information about the distribution of elements in microareas and their chemical binding forms (specia-tion). The limited sample mass implies methods with absolute detection limits as high as possible. Use of the sputtering process as a sampling technique localises the analytical zone at the outer layers of a solid, and allows analysis to progress into the interior. [Pg.627]

Applications The application of the isotope dilution technique is especially useful in carrying out precise and accurate micro and trace analyses. The most accurate results in mass spectrometry are obtained if the isotope dilution technique is applied (RSDs better than 1 % in trace analysis). Therefore, application of IDMS is especially recommended for calibration of other analytical data, and for certification of standard reference materials. The technique also finds application in the field of isotope geology, and is used in the nuclear industry for quantitative isotope analysis. [Pg.661]


See other pages where Analytical trace analysis is mentioned: [Pg.117]    [Pg.117]    [Pg.241]    [Pg.88]    [Pg.671]    [Pg.109]    [Pg.230]    [Pg.152]    [Pg.294]    [Pg.35]    [Pg.68]    [Pg.29]    [Pg.382]    [Pg.400]    [Pg.422]    [Pg.442]    [Pg.571]    [Pg.773]    [Pg.941]    [Pg.21]    [Pg.235]    [Pg.277]    [Pg.306]    [Pg.313]    [Pg.430]    [Pg.437]    [Pg.440]    [Pg.464]    [Pg.553]   