Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Activity measurement procedure

The hterature consists of patents, books, journals, and trade Hterature. The examples in patents may be especially valuable. The primary Hterature provides much catalyst performance data, but there is a lack of quantitative results characterizing the performance of industrial catalysts under industrially reaHstic conditions. Characterizations of industrial catalysts are often restricted to physical characterizations and perhaps activity measurements with pure component feeds, but it is extremely rare to find data characterizing long-term catalyst performance with impure, multicomponent industrial feedstocks. Catalyst regeneration procedures are scarcely reported. Those who have proprietary technology are normally reluctant to make it known. Readers should be critical in assessing published work that claims a relevance to technology. [Pg.183]

Procedures of the beta-galactosidase activity measuring using colour reaction with ONPG and X-Gal without cells permeabilization were developed and the detection limit at the level of 4 ppb has been achieved. The influence of the foreign ions (phosphate, sulphate, carbonate et. al) was studied. [Pg.428]

Figure 3. Ratio between the PG specific activity measured after the purification procedure (ASf) and the initial PG specific activity (ASi). Figure 3. Ratio between the PG specific activity measured after the purification procedure (ASf) and the initial PG specific activity (ASi).
Several scouting experiments were performed to find the best pH conditions. Figure 3 reports the ratio between the PG specific activity measured after the purification procedure (ASf) and the initial PG specific activity (ASi). At pH 3.5, the microspheres are able to remove from the broth the major part of the protein without PG activity, thus providing a four time increase of the enzyme specific activity. The purified PG from Kluyveromyces marxianus was immobilised following the above procedure. Batch reactions in the packed bed reactor were done to evaluate the biocatalyst stability. After an initial loss, due to enzyme release, the residual PG activity reaches a plateau value corresponding to about 40% of the initial activity. Probably, some broth component interfered during the immobilisation reaction weakening the protein-carrier interactions. [Pg.977]

The diastase activity was traditionally determined according to the Schade method in the earlier years (Schade et al., 1958). One unit of diastase activity (or more specifically, a-amylase), DN, is defined as that amoimt of enz)nne that converts 0.01 g of starch to the prescribed endpoint in 1 h at 37 °C under the experimental conditions. In this assay, a standard solution of starch, which reacts with iodine to produce a color solution, is used as a substrate for honey enzymes under the standard conditions (Rendleman, 2003). A recently developed procedure uses an insoluble, dyed starch substrate (Persano Oddo and Pulcini, 1999). As this substrate is hydrolyzed by ot-amylase, soluble dyed starch fragments are released into solution. After reaction termination and insoluble substrate removal by centrifugation, absorbance of the supernatant solution (at 620 nm) is measured. The absorbance is proportional to the diastase activity. This procedure has been widely adopted in the honey industry due to the convenience of a commercially available substrate and the simple assay format. [Pg.106]

These techniques are especially useful for studies of the adsorption of reactants, intermediates and products of electrode reactions. The simplest case corresponds to adsorption that is so strong that the electrode can be removed from the solution, rinsed and its activity measured without interference from desorption. When this procedure is impossible, the activity of the adsorbate can be measured by the electrode lowering method . The radioactive counter is placed under the bottom of the cell, which is made of a plastic foil. The electrode can be located at large distances from the bottom or can be placed so close to the bottom that only a thin layer of solution remains beneath it. The radioactivity values at the two electrode positions permit determination of the adsorbate activity. This procedure can be repeated many times, thus supplying data on the kinetics of the adsorption process. [Pg.353]

The measurement procedure is known as the pulse sequence, and always starts with a delay prior to switching on the irradiation pulse. The irradiation pulse only lasts a few microseconds, and its length determines its power. The NMR-active nuclei (here protons) absorb energy from the pulse, generating a signal. [Pg.223]

Procedure Allelochemical and a compound belonging to natural artificial pesticides and medicinal drugs is preliminary added into the reaction media (see section Add). The difference in cholinesterase activity (measured as shown in sections 15.3) between a control (without the substance added) and the experimental variant is estimated. The results are compared with the effects of the cholinesterase inhibitors neostigmine and physostigmine. [Pg.157]

An appropriate amount of hydrated iron (III) or bismuth oxide was added the oxide precipitates were prepared separately and washed thoroughly with distilled water before use [43]. After about 24 h, the samples were filtered on 0.4 jtm Nuclepore filters. The separated precipitates were dissolved with hydrochloric acid and the solutions obtained were used for /-activity measurements. In the examination of solvent extraction, chromium was measured by using 51Cr, while iron and bismuth were measured by electrothermal AAS (EAAS). The decomposition of organic complexes and other procedures were also examined by EAAS. [Pg.69]

A variety of measurement methods have been developed for determining the water activity of food materials and are well described in texts such as Rahman (1995), Wiederhold (1997), and Bell and Labuza (2000). In general, water activity is a relatively easy parameter to measure, which can be an advantage, especially for use in the food industry. Depending on the technique selected, the water activity of a food material can be measured in a time frame of minutes (e.g., electronic instrument). In addition, individuals can be trained, with a limited amount of instruction, to make water activity measurements. Consequently, when appropriate, water activity measurements can be made relatively quickly by personnel overseeing a manufacturing line for quality assurance purposes. Measurement protocols, such as calibration procedures and proper temperature control, should be implemented to assure the accuracy of online c/w measurements. [Pg.36]

Procedure 1 Activity Measurement and Partial Purification of HNL from P. mume... [Pg.269]

A rapid separation of Tc can be effected by co-precipitation of Tc from urine with copper sulfide and counting it in a proportional P coimter. For samples possibly containing other activities, the procedure applied involves measurement... [Pg.133]

Au-DENs were prepared via literature procedures (2) and deposited onto Degussa P25 Titania by stirring at pH 6 overnight. In situ infrared spectroscopy, catalyst activation, and CO oxidation experiments were performed using previously described procedures.(3) Catalyst activation under CO oxidation conditions were used 23 mg catalyst samples diluted 10 1 with a-Al203. In CO oxidation activity measurements, the feed composition was 1.1% CO, 27% O2 balance He, and the flow rate was kept constant at 20 mL/min. Conversion was measured as a function of temperature and rate data was determined only for conversions between 1 and 12%. [Pg.323]

It is relevant to ask how often the routine measurement procedures currently used in laboratory medicine provide results that are traceable to high-level calibrators and reference measurement procedures (Lequin personal communication). It turns out that primary reference measurement procedures and primary calibrators are only available for about 30 types of quantity such as blood plasma concentration of bilirubins, cholesterols and sodium ion. International reference measurement procedures from the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and corresponding certified reference material from BCR are available for the catalytic activity concentration of a few enzymes such as alkaline phosphatase and creatine kinase in plasma. For another 25 types of quantity, such... [Pg.52]

Nevertheless, manufacturers are interested in the further development of reference materials and reference measurement procedures suited for application in human serum for medical purposes. Therefore, industry appreciates the efforts started by the Joint Committee of Trace-ability and Laboratory Medicine (JCTLM), an initiative supported by the Bureau International des Poids et Mesures (BIPM) and the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) in order to develop suitable reference materials and measurement procedures, as well as to collect information on the activities of reference laboratories. In view of the limited resources and large efforts connected with these activities, clear priorities need to be set. Projects need to take into account the clinical importance of the analyte, consider the technical difficulties that must be overcome, and, most importantly, decide whether improvement of the metrological side is reflected in a gain of medically relevant information. [Pg.176]

An aspect of matrix RMs which is of considerable importance is the question of commutability or horizontal traceability. This refers to the scope of the materials, i.e. the extent to which a matrix RM of a particular composition may reliably be used to evaluate a measurement procedure that is applied to a routine test sample of a different composition. The differences in composition between a reference matrix and a routine test sample matrix must not cause the two materials to behave differently when a particular analytical method is applied. At present, the extent to which this is true is largely a matter of expert judgement based on knowledge of the measurement application. A better and more systematic understanding of the factors affecting horizontal traceability will enable users to select appropriate matrix RMs more reliably and producers to target their production activities more efficiently. [Pg.178]

Although several QA and QC activities are closely related, it should be stressed that QA and QC are not synonymous. QA covers in a broad sense all activities and procedures (managerial and technical) established in the laboratory to assure the overall quality of the delivered results, whereas QC describes the measures used to ensure the quality of individual results or a batch of results. QC is a means of evaluating the current performance of the method being used in the laboratory it can not only be performed internally in a laboratory (internal QC), but also by external assessment of the results obtained by participation in interlaboratory comparisons (ILCs). [Pg.390]

Cellulase activity of the samples was determined as filter paper activity (FPA) expressed in filter paper units (FPU) using Mandels procedure (15), and (3-glucosidase activity was assayed using 4-nitrophenyl-(3-D-glucopyranoside substrate according to Berghem and Petterson s (16) method. All samples were analyzed in triplicate and the mean values were calculated. The relative standard deviation of enzyme activity measurements was always below 5%. [Pg.204]

The bio-activity of synthesized samples was estimated from mobility parameters of unicellular microorganisms measured by Dynamic Light Scattering (DLS). The following characteristics of cell population were measured cell concentration (units/ml) % of mobile cells mean translation velocity (pm/s), cell rotational frequency of (Hz) flagella beat frequency (Hz), distribution of beat frequencies, and kinetic energy of cell motion in a viscous environment (arbitrary units). Details of experimental equipment and measurement procedures may be found elsewhere.7,8 All parameters were measured with an accuracy of about 2%.9... [Pg.279]


See other pages where Activity measurement procedure is mentioned: [Pg.213]    [Pg.19]    [Pg.410]    [Pg.526]    [Pg.58]    [Pg.707]    [Pg.287]    [Pg.108]    [Pg.284]    [Pg.133]    [Pg.57]    [Pg.275]    [Pg.103]    [Pg.125]    [Pg.371]    [Pg.351]    [Pg.381]    [Pg.618]    [Pg.105]    [Pg.52]    [Pg.127]    [Pg.249]    [Pg.14]    [Pg.287]    [Pg.24]   
See also in sourсe #XX -- [ Pg.206 , Pg.234 , Pg.356 ]




SEARCH



Activation analysis measurement procedure

Activity measure

Activity measurements

© 2024 chempedia.info