Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Thin-layer developments

The mass transfer coefficient (3C with SI units of m/s or m3/(sm2) is defined using these equations. It is a measure of the volumetric flow transferred per area. The concentration difference Aca defines the mass transfer coefficient. A useful choice of the decisive concentration difference for mass transfer has to be made. A good example of this is for mass transfer in a liquid film, see Fig. 1.41 where the concentration difference cA0 — cM between the wall and the surface of the film would be a a suitable choice. The mass transfer coefficient is generally dependent on the type of flow, whether it is laminar or turbulent, the physical properties of the material, the geometry of the system and also fairly often the concentration difference Aca. When a fluid flows over a quiescent surface, with which a substance will be exchanged, a thin layer develops close to the surface. In this layer the flow velocity is small and drops to zero at the surface. Therefore close to the surface the convective part of mass transfer is very low and the diffusive part, which is often decisive in mass transfer, dominates. [Pg.76]

Figure 16.1 Separation of a nine-component amino acid mi)cture (0.5 p,g each) on a Whatman KCis thin layer developed with n-propanol-water (7 3) in a saturated chamber. F, solvent front 0, origin Arg, arginine His, histidine Cys, cysteine Ser, serine Thr, threonine Ala, alanine Asp, aspartic acid Val, valine Trp, tryptophan. [Reproduced with the permission of Marcel Dekker, Inc., from Sherma et al. (1983).]... Figure 16.1 Separation of a nine-component amino acid mi)cture (0.5 p,g each) on a Whatman KCis thin layer developed with n-propanol-water (7 3) in a saturated chamber. F, solvent front 0, origin Arg, arginine His, histidine Cys, cysteine Ser, serine Thr, threonine Ala, alanine Asp, aspartic acid Val, valine Trp, tryptophan. [Reproduced with the permission of Marcel Dekker, Inc., from Sherma et al. (1983).]...
FDNP- and DNP-pyridoxamine-P can be chromatographed on a cellulose thin layer developed in water/acetone/tert-amyl alcohol/acetic acid (20/35/40/5) their respective Rf values are 0.56-0.61 and 0.50-... [Pg.444]

Figure 9 depicts the SEM of the specimen surface after 60 days of immersion in seawater with the addition of 1000 ppm of NH. It can be seen that the flakes in the surface of the specimens decreased as compared to that of the micrograph in Figure 8. The specimen is covered with the inhibitor molecules giving a protection against corrosion, where a thin layer developed on the specimen surfaces. Figure 9 depicts the SEM of the specimen surface after 60 days of immersion in seawater with the addition of 1000 ppm of NH. It can be seen that the flakes in the surface of the specimens decreased as compared to that of the micrograph in Figure 8. The specimen is covered with the inhibitor molecules giving a protection against corrosion, where a thin layer developed on the specimen surfaces.
Fig 2-Elution profile from a DEAE cellulose column(cm 2 X 30).Elution buffer 10 mM Tris-Cl,pH 8 500 mg proteins. Specific activity= 4moles " C02/hr/g. Insert=chromatographic pattern of active fraction on cellulose thin layer developped in butanol-pyridine -acetic acid-water(45 30 9 36)and sprayed with ninhydrin. [Pg.348]

An electrochemical vapor deposition (EVD) technique has been developed that produces thin layers of refractory oxides that are suitable for the electrolyte and cell interconnection in SOFCs (9). In this technique, the appropriate metal chloride (MeCl ) vapor is introduced on one side of a porous support tube, and H2/H2O gas is introduced on the other side. The gas environments on both sides of the support tube act to form two galvanic couples, ie. [Pg.581]

Analytical methods iaclude thin-layer chromatography (69), gas chromatography (70), and specific methods for determining amine oxides ia detergeats (71) and foods (72). Nuclear magnetic resonance (73—75) and mass spectrometry (76) have also been used. A frequentiy used procedure for iadustrial amine oxides (77) iavolves titratioa with hydrochloric acid before and after conversion of the amine to the quaternary ammonium salt by reaction with methyl iodide. A simple, rapid quaHty control procedure has been developed for the deterrniaation of amine oxide and unreacted tertiary amine (78). [Pg.192]

Gas chromatography (gc) is inferior to hplc in separating abiUty. With gc, it is better to use capillary columns and the appHcation is then limited to analysis (67). Resolution by thin layer chromatography or dc is similar to Ic, and chiral stationary phases developed for Ic can be used. However, tic has not been studied as extensively as Ic and gc. Chiral plates for analysis and preparation of micro quantities have been developed (68). [Pg.279]

Thin-Layer Chromatography (tic). Tic (126) is used widely for quahtative analysis and micro-quantity separation of amino acid mixtures. The amino acids detected are developed by ninhydrin coloring, except for proline and hydroxyproline. Isatia has been recommended for specific coloring of pToline (127). [Pg.285]

The nonquantitative detection of radioactive emission often is required for special experimental conditions. Autoradiography, which is the exposure of photographic film to radioactive emissions, is a commonly used technique for locating radiotracers on thin-layer chromatographs, electrophoresis gels, tissue mounted on sHdes, whole-body animal sHces, and specialized membranes (13). After exposure to the radiolabeled emitters, dark or black spots or bands appear as the film develops. This technique is especially useful for tritium detection but is also widely used for P, P, and 1. [Pg.439]

Several heterostructure geometries have been developed since the 1970s to optimize laser performance. Initial homojunction lasers were advanced by the use of heterostmctures, specifically the double-heterostmcture device where two materials are used. The abiUty of the materials growth technology to precisely control layer thickness and uniformity has resulted in the development of multiquantum well lasers in which the active layer of the laser consists of one or mote thin layers to allow for improved electron and hole confinement as well as optical field confinement. [Pg.378]

Chromatographic methods including thin-layer, hplc, and gc methods have been developed. In addition to developments ia the types of columns and eluents for hplc appHcations, a significant amount of work has been done ia the kiads of detectioa methods for the vitamin. These detectioa methods iaclude direct detectioa by uv, fluoresceace after post-column reduction of the quiaone to the hydroquinone, and electrochemical detection. Quantitative gc methods have been developed for the vitamin but have found limited appHcations. However, gc methods coupled with highly sensitive detection methods such as gc/ms do represent a powerful analytical tool (20). [Pg.152]

The successful separation of xanthate-related compounds by high performance Hquid chromatography (hplc) methods has been reported (91—93). The thin-layer chromatography procedure has been used to determine the nature of the alcohols in a xanthate mixture. A short mn of 3 cm at a development time of 25 min gives a complete separation of C —alkanol xanthates (94). [Pg.367]

The bulk of synthetic industrial diamond production consists of the smaller crystal sizes up to 0.7-mm particle size (25 mesh). This size range has wide utihty in industry, and a significant fraction of the world s need for diamond abrasive grit is now met by synthetic production yielding thousands of kilograms per year. Because the raw materials are plentiful, synthetic production could, if necessary, supply the world demand for diamond abrasive. Development work continues in order to improve size and utility of the manufactured product and to realize the full potential of diamonds at minimum cost. An appreciable increase in performance has been obtained by coating the diamonds with a thin layer of nickel or copper, before incorporating them into wheels. The thin layer of metal apparendy improves adhesion and heat transfer. [Pg.566]

Inhalation of high concentrations of monochlorotoluenes will cause symptoms of central nervous system depression. Inhalation studies produced an LC q (rat, 4 h) of 7119 ppm for o-chlorotoluene (68). o- and Chlorotoluene are both considered moderately toxic by ingestion (Table 2). A study of the relationship between the electronic stmcture and toxicity parameters for a series of mono-, di-, and tri-chlorotoluenes has been reviewed (72). A thin-layer chromatographic method has been developed to assess the degree of occupational exposure of workers to chlorotoluenes by determining j -cblorobippuric... [Pg.54]

SemiadditiveMethod. The semiadditive method was developed to reduce copper waste. Thin 5.0 lm (4.5 mg/cm ) copper foil laminates are used, or the whole surface may be plated with a thin layer of electroless copper. Hole forming, catalysis, and electroless copper plating are done as for subtractive circuitry. A strippable reverse—resist coating is then appHed. Copper is electroplated to 35 p.m or more, followed by tin or tin—lead plating to serve as an etch resist. The resist is removed, and the whole board is etched. The original thin copper layer is quickly removed to leave the desired circuit. This method wastes less than 10% of the copper. [Pg.112]

The procedure of determination of metals in the thin layer without elimination of the non-volatile organic components for different paints containing inorganic pigments was developed. Several techniques of sampling from paint-and-lacquer materials for X-ray fluorescence analysis were proposed. For the study of nonhomogenity of metal distribution in the thin layer we used additionally the local method of X-ray fluorescence analysis. [Pg.137]

One of trends of development of thin-layer chromatography implies that replacement of aqueous-organic eluents by micellar surfactants solution. This is reduces the toxicity, flammability, environmental contamination and cost of the mobile phases, reduce sample prepar ation in some cases. [Pg.350]


See other pages where Thin-layer developments is mentioned: [Pg.247]    [Pg.185]    [Pg.248]    [Pg.876]    [Pg.3384]    [Pg.247]    [Pg.185]    [Pg.248]    [Pg.876]    [Pg.3384]    [Pg.97]    [Pg.855]    [Pg.1098]    [Pg.1948]    [Pg.60]    [Pg.60]    [Pg.493]    [Pg.134]    [Pg.285]    [Pg.287]    [Pg.69]    [Pg.388]    [Pg.24]    [Pg.15]    [Pg.51]    [Pg.244]    [Pg.295]    [Pg.396]    [Pg.496]    [Pg.109]    [Pg.485]    [Pg.508]    [Pg.117]    [Pg.131]    [Pg.178]    [Pg.1097]    [Pg.65]    [Pg.358]   
See also in sourсe #XX -- [ Pg.159 , Pg.160 , Pg.161 , Pg.162 , Pg.163 , Pg.164 , Pg.165 , Pg.166 , Pg.167 , Pg.168 , Pg.169 , Pg.170 , Pg.171 , Pg.172 , Pg.173 , Pg.174 ]




SEARCH



Development of Thin-Layer Chromatograms

Development of thin layers

Elution Development in Thin Layer Chromatography

Method development thin layer chromatography

Thin layer chromatography development

Thin layer chromatography multiple development

Thin-layer chromatography plate development

© 2024 chempedia.info