Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Supervisory control and data acquisition system SCADA

Control System Included in this classification are Supervisory Control and Data Acquisition Systems (SCADA), Distributed Control Systems (DCS), Statistical Process Control systems (SPC), Programmable Logic Controllers (PLCs), intelligent electronic devices, and computer systems that control manufacturing equipment or receive data directly from manufacturing equipment PLCs. [Pg.179]

Larger, commercial installations will also be equipped with a Supervisory Control And Data Acquisition system (SCADA). The SCADA system is connected via a data highway with the PLC(s) used in the system. [Pg.117]

Mr. Evans is a lead consultant in computer systems and medical device validation. He has 27 years experience with Supervisory Control and Data Acquisition Systems (SCADA) and Distributed Control Systems (DCSs) within the chemical and pharmaceutical industries. During the last 7 years, Mr. Evans has had specific responsibilities for ensuring the GMP compliance of these systems to U.S. Food and Drug Administration (FDA) and UK Medicines... [Pg.483]

Increasingly the senior technicians function as supervisors for computer control systems such as Distributed Control Systems (DCS) or Supervisory Control and Data Acquisition Systems (SCADA). These technicians need procedures that help them work with the electronic interface, generally as troubleshooters for when the electronic systems go awry, or for when the control systems fail. [Pg.285]

Basic Supervisory Control and Data Acquisition Systems (SCADA) Pressure testing for steel and plastic pipelines Hot tapping and stopping Characteristics and properties of natural gas Excavation safety Compressor operation Pipeline purging Valve maintenance Cathodic protection... [Pg.389]

Fiset, J. 2009. Human-Machine Interface Design for Process Control Applications. Research Triangle Park, NC Instrumentation, Systems, and Automation Society. Written for designers and industrial control personnel, this book discusses three basic human-machine interfaces distributed control systems (DCSs), supervisory control and data acquisition system (SCADA), and stand-alone units. [Pg.356]

To date, process control systems like Programmable Logic Controllers (PLCs) have only enabled paperless operation in combination with SCADA (Supervisory Control and Data Acquisition) systems or as part of a DCS (Distributed Control System), which enable measurement and control actions to be recorded and used as part of batch documentation. Process control systems have the advantage that they focus on real-time data as a necessary part of both control and supervision. The real-time focus is very useful for implementing both active and proactive control when combined with, for example, statistical tools or predictive algorithms. [Pg.22]

SCADA (Supervisory Control and Data Acquisition) systems Batch record systems Building Management Systems (BMSs)... [Pg.148]

Scada (Supervisory Control and Data Acquisition) Systems collect 30 data, monitor manufacturing processes, and produce management reports on the effectiveness of manufacturing processes. Are often PC systems and use graphical displays to alert shop-floor staff to problems in a process. [Pg.113]

Determination of critical assets that might be subject to malevolent acts that could result in undesired consequences What are the malevolent acts that could reasonably cause undesired consequences on these assets electronic, computer, or other automated systems that are utilized by the public water system (e.g., Supervisory Control and Data Acquisition (SCADA)) the use, storage, or handling of various chemicals the operation and maintenance of such systems... [Pg.69]

System interface with hardware supervisory control and data acquisition (SCADA) program... [Pg.144]

Control of the field occurs on two levels. The upper level Is the supervisory control and data acquisition (SCADA) system whose main responsibility is well flow rate control, well testing, production allocation, accounting and general field monitoring. The SCADA system is operated from the Main Operations Center (MOC) which is remote from all three GCs. The second level of control is process control in the individual GCs. Flow to the GCs Is normally controlled by the SCADA system (HOC operator), but the GC operator can override and control well flow rates in case of SCADA system failure or other unusual circumstances. The GC operator and the MOC operator communicate via a dedicated telephone connection. [Pg.56]

Since the operation is in an arctic environment, achieving the above objectives presents particular problems and would be difficult and Inefficient using the more conventional approaches. Therefore, as part of the original facilities a "supervisory control and data acquisition" (SCADA) system was Installed in the VfOA. The operational philosophy is one where, by means of the SCADA system, the functions necessary for reservoir management and production control could be monitored and controlled from a central location called the Main Operations Center [Pg.57]

The crude oil delivery system starts with relatively small-diameter gathering lines from individual producing wells to a main-line pump station, from where it is pumped through a larger transmission trunkline to a refinery or other destination. At the refinery, the cmde oil is separated into gasoline, jet fuel, kerosene, distillate fuel oil, etc, and the refined products are transported by products pipelines to markets, storage, shipping terminals, etc. In modem lines, all inputs and outputs are metered, monitored, and remotely controlled by supervisory control and data acquisition (SCADA) computer systems. [Pg.47]

Microprocessor-based control systems are marketed under a variety of acronyms and not all will be true DCCSs. Of particular note are the Supervisory Control and Data Acquisition (SCADA) systems which form an increasingly central part of the operations of many industries (e.g. offshore oil and gas platforms, petrochemical complexes, pulp and paper works). SCADA describes a communications system whose principal function is to join instrumentation and control into a cohesive package(57) and, particularly, the supervision and management of remote ... [Pg.708]

Stand-alone systems. Multiloop controllers) or programmable logic controllers (PLC) typically used to control part of a process, and larger supervisory control and data acquisition (SCADA) systems/distributed control systems (DCS) used to control the process or service as a whole (e.g., bulk primary production plant, building management systems). These self-contained systems are a component of an automated manu-... [Pg.588]

The control system of the freeze-drying unit provides control, monitoring and documentation of the process. Such a system must be reliable and comply with GM P and GAMP (Good Automation Manufacturing Practice) demands with respect to computer validation. It should be SCADA (Supervisory Control and Data Acquisition) compatible. A possible hardware architecture is shown in Figure 2.55.1. [Pg.222]

Incorrectly implemented calculations moving averages in Supervisory Control and Data Acquisition (SCADA) systems, material mixing concentrations in DCS systems, flawed shelf-life date calculations in Laboratory Information Management Systems (LIMS). [Pg.224]

Data acquisition is provided by instrumentation. Chemometrics, on-line prediction, and reporting are typically supported by some kind of Supervisory Control And Data Acquisition (SCADA) system and/or Manufacturing Execution System (MES). This may be a COTS product or a custom development. Data Historian is likely to be a separate interfaced application. To support this and exchange of information with other systems an open systems approach should be adopted. [Pg.937]

The vahdation of analytical methods that are based on arrays of sensors cannot rely on the traditional pharmaceutical approach. Many of the vahdation headings have no equivalent, and important steps, such as vahdation of software, are not explicitly included. The pharmaceutical industry does, however, have a model for vahdation that could be used in modern analytical chemistry, namely the vahdation of programmable logic controllers (PLC) [26] and supervisory control and data acquisition (SCADA) [27] systems. This was the subject of a recent issue of the journal Measurement and Control [1]. Of importance is now the process of vahdation, which may be broken down into a number of steps (Fig. 1). [Pg.137]

All capsule pipeline systems include a pipe, many capsules, an injection system to inject capsules into the pipe, a pumping system to pump the fluid and capsules through the pipe, an ejection system to eject the capsules from the pipe, an instrumentation system to monitor the flow rate, pressure, temperature, and the passage of capsules at key locations, and an automatic control system that uses programmable logic controllers and an SCADA (Supervisory Control and Data Acquisition). [Pg.301]


See other pages where Supervisory control and data acquisition system SCADA is mentioned: [Pg.1242]    [Pg.112]    [Pg.383]    [Pg.410]    [Pg.1166]    [Pg.1242]    [Pg.112]    [Pg.383]    [Pg.410]    [Pg.1166]    [Pg.432]    [Pg.118]    [Pg.47]    [Pg.10]    [Pg.135]    [Pg.169]    [Pg.281]    [Pg.94]    [Pg.223]    [Pg.18]    [Pg.420]    [Pg.588]    [Pg.619]    [Pg.682]    [Pg.45]    [Pg.383]    [Pg.473]   
See also in sourсe #XX -- [ Pg.1242 ]




SEARCH



Control Data

Data acquisition

Data systems

SCADA

SCADA acquisition system

SYSTEM ACQUISITION

Supervisory control

Supervisory control and data acquisition

Supervisory control and data acquisition system

Supervisory controllers

Supervisory system

System Control and data acquisition, SCADA

System control and data acquisition