5 Instrumen tntion. At the pump house each of the four cooling-,. water pump motors is provided with an ammeter. A voltmeter is provided across [Pg.404]

6 Emergemcy Operation. In the event of power failure, the cooling--tower system is shut down completely, and the flow of make-up water is automatically stopped. Make-up water is also shut off automatically if the general water reservoir content is low. [Pg.405]


The term gathering station may describe anything from a very simple gathering and pumping station to a complex processing centre in which produced fluids are treated and separated into gas, NGLs and stabilised crude. [Pg.261]

High strength, low alloy (HSLA) steels often contain 0.10—0.30% molybdenum. These steels exhibit toughness at low temperatures and good weldabiHty. They are used extensively for undersea pipelines (qv) transporting gas and oil from offshore weUs to pumping stations on shore, and are also used extensively in remote Arctic environments. [Pg.467]

Auxiliary huildings Sanitary-waste pumping stations... [Pg.863]

Pipe-hue pumping stations usually range from 16 to 160 km (10 to 100 miles) apart, with maximum pressures up to 6900 kPa (1000 Ibf/ in") and velocities up to 3 m/s (10 ft/s) for liquid. Gas pipe lines have higher velocities and may have greater spacing of stations. [Pg.1020]

A cathode cable is adequate for the return path of the protection current for individual storage tanks. In pumping stations with several storage tanks, each tank must be provided with a cable connection. If the tanks are connected to each other by electrical connections, then two cathode cable connections must be provided [2]. [Pg.294]

The raw material at this plant is natural gas supplied by the El Paso Natural Gas Company from a nearby pumping station. In each process train, gas is compressed to 850 psig, dehydrated by an adsorption method to remove 100% of the water, then passed through a refrigeration unit to lower the temperature to -60°F. A separator removes liquids upstream of the turboexpander. [Pg.441]

General recommendations for spacing General Recommendations for Spacing in Refineries, Petrochemical Plants, Casoline Plants, Terminals, Oil Pump Stations and Offshore Properties (Oil Insurance Association, No. 361)... [Pg.402]

Backwashing requires locating a source that will supply the necessary flow and pressure of wash water. This water can be provided either by a reservoir at a higher location or by a pumping station that pumps treated water. Sometimes an automated... [Pg.258]

Diameters are up to 600ft with operating torques of4,000,000 ft.-Lbs. The center pier forms the control and pumping station, as well as support for the rake assembly. The underflow is pumped up through the caisson. [Pg.277]

Remediation aetivities ineluded site mobilization (i.e., installation of trailers, utilities, and equipment elearing and grubbing grading roads and eonstruetion of deeontamination faeilities, drainage pump stations, and a water treatment system), soil exeavation, thermal proeessing of 7,700 eubie yards of soil, baekfilling and regrading the exeavated area, and site demobilization. [Pg.181]

Manor Way, A1014 provides road access to the mainland a rail line for freight nms fmiii the main line through the Shell UK Oil refinery to Thames Haven, and to the Mobil Oil disiribution terminal at Coi-yton. A deep water channel provides access to the ten jetties of the two refineries. The control room and pumping station for the U.K. oil pipeline is located at Coryton. Oil products are transported by pipeline from Texaco Ltd on Canvey Island and from the two oil refineries ou the mainland Helicopters from the site landing pad. survey the pprelines. [Pg.429]

In 1984, an explosion in a water pumping station at Abbeystead, UK, killed 16 people, most of them local residents who were visiting the plant. Water was pumped from one river to another through a tunnel. When pumping was stopped, some water was allowed to drain out of the tunnel and leave a void. Methane from the rocks below accumulated in the void and, when pumping was restarted, was pushed through vent valves into a valvehouse, where it exploded [18J. [Pg.73]

Pumping stations are often unattended and may be remotely controlled by radio or telephone circuits. [Pg.416]

In this procedure, increasing the supply temperature is considered to reduce the investment cost for the distribution system and electrical energy required for pumping stations. However, this change increases heat losses in the distribution network. [Pg.227]


See other pages where Pumping station is mentioned: [Pg.364]    [Pg.348]    [Pg.47]    [Pg.49]    [Pg.49]    [Pg.12]    [Pg.863]    [Pg.2219]    [Pg.173]    [Pg.766]    [Pg.299]    [Pg.317]    [Pg.124]    [Pg.369]    [Pg.329]    [Pg.505]    [Pg.505]    [Pg.599]    [Pg.246]    [Pg.15]    [Pg.24]    [Pg.948]    [Pg.949]    [Pg.416]    [Pg.300]    [Pg.59]    [Pg.64]    [Pg.153]    [Pg.154]    [Pg.166]   