Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Secondary mass spectroscopy

There are two principal subdivisions in molecular spectroscopy in-situ and non-in-situ methods (2,75). The principal invasive non-in-situ techniques used for soil and aquatic systems are x-ray photoelectron spectroscopy (XPS), auger electron spectroscopy (AES), and secondary mass spectroscopy (SIMS). Each of these techniques yields detailed information about the structure and bonding of minerals and the chemical species present on the mineral surfaces. [Pg.112]

Many aspects related to the surface of electronic components were recently discussed, such as, effect of composition of the passivation layer on adhesion in flip-chip packaging, use of time-of-flight secondary mass spectroscopy in detection of mold release agents in near surface regions, x-ray lithography, defects of coatings in the presence of inorganic antiblocks, use of silicon nitride molds " and diamond dies, and nanoscopic pattern transfer. ... [Pg.215]

SIMS Secondary-ion mass spectroscopy [106, 166-168] (L-SIMS liquids) [169, 170] Ionized surface atoms are ejected by impact of -1 keV ions and analyzed by mass spectroscopy Surface composition... [Pg.316]

SIMS Secondary Ion mass spectroscopy A beam of low-energy Ions Impinges on a surface, penetrates the sample and loses energy In a series of Inelastic collisions with the target atoms leading to emission of secondary Ions. Surface composition, reaction mechanism, depth profiles... [Pg.1852]

NIRMS = noble-gas-ion reflection mass spectrometry OSEE = optically stimulated exoelectron emission PES = photoelectron spectroscopy PhD = photoelectron diffraction SIMS = secondary ion mass spectroscopy UPS = ultraviolet photoelectron spectroscopy ... [Pg.398]

Secondary Ion Mass Spectroscopy (SIMS). When the p-n junction and the GaAs/GaAlAs heterojunction are not coincident, carrier recombination occurs, reducing the current and the performance of fabricated heterojunction bipolar transistors. [Pg.394]

The main experimental techniques used to study the failure processes at the scale of a chain have involved the use of deuterated polymers, particularly copolymers, at the interface and the measurement of the amounts of the deuterated copolymers at each of the fracture surfaces. The presence and quantity of the deuterated copolymer has typically been measured using forward recoil ion scattering (FRES) or secondary ion mass spectroscopy (SIMS). The technique was originally used in a study of the effects of placing polystyrene-polymethyl methacrylate (PS-PMMA) block copolymers of total molecular weight of 200,000 Da at an interface between polyphenylene ether (PPE or PPO) and PMMA copolymers [1]. The PS block is miscible in the PPE. The use of copolymers where just the PS block was deuterated and copolymers where just the PMMA block was deuterated showed that, when the interface was fractured, the copolymer molecules all broke close to their junction points The basic idea of this technique is shown in Fig, I. [Pg.223]

The interface properties can usually be independently measured by a number of spectroscopic and surface analysis techniques such as secondary ion mass spectroscopy (SIMS), X-ray photoelectron spectroscopy (XPS), specular neutron reflection (SNR), forward recoil spectroscopy (FRES), scanning electron microscopy (SEM) and transmission electron microscopy (TEM), infrared (IR) and several other methods. Theoretical and computer simulation methods can also be used to evaluate H t). Thus, we assume for each interface that we have the ability to measure H t) at different times and that the function is well defined in terms of microscopic properties. [Pg.354]

The most widely used techniques for surface analysis are Auger electron spectroscopy (AES), x-ray photoelectron spectroscopy (XPS), secondary ion mass spectroscopy (SIMS), Raman and infrared spectroscopy, and contact angle measurement. Some of these techniques have the ability to determine the composition of the outermost atomic layers, although each technique possesses its own special advantages and disadvantages. [Pg.517]

X-ray scattering studies at a renewed pc-Ag/electrolyte interface366,823 provide evidence for assuming that fast relaxation and diffu-sional processes are probable at a renewed Sn + Pb alloy surface. Investigations by secondary-ion mass spectroscopy (SIMS) of the Pb concentration profile in a thin Sn + Pb alloy surface layer show that the concentration penetration depth in the solid phase is on the order of 0.2 pm, which leads to an estimate of a surface diffusion coefficient for Pb atoms in the Sn + Pb alloy surface layer on the order of 10"13 to lCT12 cm2 s i 820 ( p,emicai analysis by electron spectroscopy for chemical analysis (ESCA) and Auger ofjust-renewed Sn + Pb alloy surfaces in a vacuum confirms that enrichment with Pb of the surface layer is probable.810... [Pg.144]

The control of materials purity and of environmental conditions requires to implement physico-chemical analysis tools like ESC A, RBS, AUGER, SEM, XTM, SIMS or others. The principle of SIMS (Secondary Ion Mass Spectroscopy) is shown in Eig. 31 an ion gun projects common ions (like 0+, Ar+, Cs+, Ga+,. ..) onto the sample to analyze. In the same time a flood gun projects an electron beam on the sample to neutralize the clusters. The sample surface ejects electrons, which are detected with a scintillator, and secondary ions which are detected by mass spectrometry with a magnetic quadrupole. [Pg.340]

The brief history, operation principle, and applications of the above-mentioned techniques are described in this chapter. There are several other measuring techniques, such as the fluorometry technique. Scanning Acoustic Microscopy, Laser Doppler Vibrometer, and Time-of-flight Secondary Ion Mass Spectroscopy, which are successfully applied in micro/nanotribology, are introduced in this chapter, too. [Pg.7]

Benninghoven, A., Surface Investigation of Solids by the Static Mmethod of Secondary Ion Mass Spectroscopy (SIMS), Surf Set., Vol. 35,1973, pp. 427-457. [Pg.36]


See other pages where Secondary mass spectroscopy is mentioned: [Pg.201]    [Pg.224]    [Pg.201]    [Pg.201]    [Pg.224]    [Pg.201]    [Pg.559]    [Pg.692]    [Pg.1264]    [Pg.269]    [Pg.269]    [Pg.356]    [Pg.50]    [Pg.526]    [Pg.311]    [Pg.235]    [Pg.391]    [Pg.518]    [Pg.835]    [Pg.389]    [Pg.358]    [Pg.362]    [Pg.363]    [Pg.367]    [Pg.374]    [Pg.36]    [Pg.36]    [Pg.12]    [Pg.317]    [Pg.3]    [Pg.67]   
See also in sourсe #XX -- [ Pg.283 ]




SEARCH



Dynamic secondary ion mass spectroscopy

Dynamic secondary ion mass spectroscopy DSIMS)

Mass spectroscopy

Secondary Ion Mass Spectroscopy

Secondary ion mass spectroscopy surfaces

Secondary neutral mass spectroscopies

Secondary-ion mass spectroscopy, SIMS

Static secondary ion mass spectroscopy

Static secondary ion mass spectroscopy SSIMS)

Surface analysis secondary neutral mass spectroscopies

Time-of-flight secondary ion mass spectroscopy

Time-of-flight secondary ion mass spectroscopy ToF SIMS)

© 2024 chempedia.info