Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

In-situ techniques

The presented examples clearly demonstrate tliat a combination of several different teclmiques is urgently recommended for a complete characterization of tire chemical composition and tire atomic stmcture of electrode surfaces and a reliable interiDretation of tire related results. Stmcture sensitive metliods should be combined witli spectroscopic and electrochemical teclmiques. Besides in situ techniques such as SXS, XAS and STM or AFM, ex situ vacuum teclmiques have proven tlieir significance for tlie investigation of tlie electrode/electrolyte interface. [Pg.2755]

Ex situ bioremediation may use various biological wastewater treatment processes, soil piles, or land appHcation. With in situ bioremediation, the basic process is the same microbes, soil, and water working together as a bioreactor. Where the in situ techniques differ are in how contaminants and microbes are brought in contact and how oxygen, nutrients, and other chemical supplements ate distributed in the soil—water—air matrix. Typical in situ bioremediation techniques include natural or intrinsic attenuation, air sparging, and bioventing. [Pg.170]

The electrodesposition process of conducting polymers can be monitored by spectroelectrochemical in situ techniques Especially useful are ellipsometric... [Pg.37]

Transmission infrared spectroscopy is very popular for studying the adsorption of gases on supported catalysts and for studying the decomposition of infrared active catalyst precursors during catalyst preparation. Infrared spectroscopy is an in situ technique that is applicable in transmission or diffuse reflection mode on real catalysts. [Pg.158]

The second approach is to study real catalysts with in situ techniques such as infrared and Mossbauer spectroscopy, EXAFS and XRD, under reaction conditions, or, as is more often done, under a controlled environment after quenching of the reaction. The in situ techniques, however, are not sufficiently surface specific to yield the desired atom-by-atom characterization of the surface. At best they determine the composition of the particles. [Pg.166]

The dilemma is thus investigations of real catalysts under relevant conditions by in situ techniques give little information on the surface of the catalyst, while techniques that are surface sensitive can often only be applied on model surfaces under vacuum. Bridging the gap between UHV and high pressures and between the surfaces of single crystals and of real catalysts is therefore an important issue in catalysis. [Pg.166]

It is only since 1980 that in situ spectroscopic techniques have been developed to obtain identification of the adsorbed intermediates and hence of reliable reaction mechanisms. These new infrared spectroscopic in situ techniques, such as electrochemically modulated infrared reflectance spectroscopy (EMIRS), which uses a dispersive spectrometer, Fourier transform infrared reflectance spectroscopy, or a subtractively normalized interfacial Fourier transform infrared reflectance spectroscopy (SNIFTIRS), have provided definitive proof for the presence of strongly adsorbed species (mainly adsorbed carbon monoxide) acting as catalytic poisons. " " Even though this chapter is not devoted to the description of in situ infrared techniques, it is useful to briefly note the advantages and limitations of such spectroscopic methods. [Pg.76]

Dott W, D Eeidieker, M Steiof, PM Beckerm, P Kampfer (1995) Comparison of ex situ and in situ techniques for bioremediation of hydrocarbon-polluted soils. Int Biodet Biodeg 35 301-316. [Pg.634]

STM, X-ray reflectivity, and AFM are excellent in situ techniques for studying surface topography and morphology. Scanning electron microscopy is a useful ex situ technique. [Pg.469]

A wide variety of in situ techniques are available for the study of anodic hhns. These include reflectance, eUipsometry, X-ray reflectivity, and SXRD. X-ray reflectivity can be used to study thick surface layers up to 1000 A. The reflectance technique has been used to study oxide growth on metals, and it yields information on oxide thickness, roughness, and stoichiometry. It the only technique that can give information on buried metal-oxide interfaces. It is also possible to get information on duplex or multiple-layer oxide hhns or oxide hhns consisting of layers with different porosity. Films with thicknesses of anywhere from 10 to 1000 A can be studied. XAS can be used to study the chemistry of dilute components such as Cr in passive oxide hhns. [Pg.470]

The advantages of elUpsometry are that it is an in situ technique that can be used to study film growth on electrodes. The main disadvantage is that it does not provide chemical information. [Pg.497]

Christensen, P, and A. Hamnett, In-situ techniques in electrochemistry ellipsometry and FTIR, Electrochim. Acta, 45, 2443 (2000). [Pg.518]

The industrial catalyst for n-butane oxidation to maleic anhydride (MA) is a vanadium/phosphoras mixed oxide, in which bulk vanadyl pyrophosphate (VPP) (VO)2P207 is the main component. The nature of the active surface in VPP has been studied by several authors, often with the use of in situ techniques (1-3). While in all cases bulk VPP is assumed to constitute the core of the active phase, the different hypotheses concern the nature of the first atomic layers that are in direct contact with the gas phase. Either the development of surface amorphous layers, which play a direct role in the reaction, is invoked (4), or the participation of specific planes contributing to the reaction pattern is assumed (2,5), the redox process occurring reversibly between VPP and VOPO4. [Pg.485]

Frick, C.M., Farrel, R.E. and Germida, J.J., Assessment of Phytoremediation as an In-Situ Technique for Cleaning Oil-Contaminated Sites, Petroleum Technology Alliance of Canada, Calgary, AB, 1999. [Pg.568]

Incorporating reinforcing particles that respond to a magnetic field is important with regard to aligning the particles to improve mechanical properties anisotropically [223-226]. In related work, some in-situ techniques have been used to generate electrically conducting fillers such as polyaniline within an elastomeric material [227],... [Pg.372]

Hence, for modern FRET and FLIM techniques in Molecular Biology and Biochemistry it is important to keep the enthusiasm for the in situ technique, yielding unprecedented rich information on molecular states in live cells, and to keep the advantages of easy labeling techniques, modern microscopes and automated data processing. However, we need to educate the new generations of FRET scientists in the theoretical background of the technique, how it should be done correctly, and what the sources of errors are. Only then it will be clear that FRET-(FLIM) is a very direct, robust, extremely sensitive, and reliable technique. [Pg.10]

Again, voltammetry alone is insufficient to shod any light on the electrochemistry of these systems As will be seen in the next chapter, the application of a range of In situ techniques was required before any major advanoes in understanding were obtained... [Pg.72]

Spectroelectrochemical cells for use in the UV-visible region are not, of course, constrained by solvent absorption and can thus be of a reasonable size to give acceptable electrochemical behaviour. However, as with all the in situ techniques discussed in this book, a thin-layer approach is one of the methods employed. [Pg.204]

The verification of the presence of hydrogen in the film has proved more controversial, primarily because many of the structural investigations have been carried out after the film has been dried in vacuo. An example of the problems here is the fact that electron diffraction, which has to be carried out in vacuo, reveals a relatively well-crystallised spinel lattice whose origin may be the comparatively high sample heating encountered in the electron beam. Moreover, the use of in situ techniques, such as Mossbauer and X-ray absorption spectroscopy, clearly reveals marked differences between the spectra of the films in situ and the spectra of the same films ex situ as well as the spectra of y-Fe203 and y-FeOOH standards. These differences are most naturally ascribed to hydration of the spinel forms. [Pg.331]

Hence the authors concluded that bipolarons are the major current carriers on the basis of the calculation showing them to be 0.49 eV more stable than two polarons, with polarons combining where possible to give bipolarons. This paper dominated the interpretation of experiments on polypyrrole for several years until in situ techniques became routinely applied,... [Pg.341]

An in situ technique for measuring fluorescence in the ocean has been developed by Egan [425]. His sensors, set to measure separately both chlorophyll and Gelbstoff fluorescence, can be lowered to 600 m and operate unattended. [Pg.430]


See other pages where In-situ techniques is mentioned: [Pg.541]    [Pg.954]    [Pg.200]    [Pg.143]    [Pg.45]    [Pg.189]    [Pg.233]    [Pg.85]    [Pg.544]    [Pg.294]    [Pg.131]    [Pg.469]    [Pg.81]    [Pg.104]    [Pg.45]    [Pg.522]    [Pg.540]    [Pg.575]    [Pg.77]    [Pg.515]    [Pg.70]    [Pg.224]    [Pg.401]    [Pg.16]    [Pg.97]    [Pg.191]    [Pg.151]   
See also in sourсe #XX -- [ Pg.166 ]

See also in sourсe #XX -- [ Pg.66 ]

See also in sourсe #XX -- [ Pg.19 ]

See also in sourсe #XX -- [ Pg.31 , Pg.46 , Pg.55 ]

See also in sourсe #XX -- [ Pg.19 ]

See also in sourсe #XX -- [ Pg.173 ]

See also in sourсe #XX -- [ Pg.54 ]

See also in sourсe #XX -- [ Pg.173 ]

See also in sourсe #XX -- [ Pg.51 ]




SEARCH



In Situ Combinations of Electrochemistry with Other Techniques

In situ characterization techniques

In situ methods and simulation techniques

In situ microscopic techniques

In situ monitoring technique

In situ product removal technique

In situ spectroscopic techniques

Noninvasive in situ techniques

Other in situ techniques

Properties of PS-MMT Nanocomposites Prepared via In-situ Techniques

Relationship of XAS to Other Surface Science and in Situ Techniques

Sample Preparation Techniques for in Situ NMR

Situ Techniques

© 2024 chempedia.info