Offline methods

A variety of online solid extraction devices and applications have been developed for bioanalysis. Many are easy to build in laboratories or commercially available. Unlike offline methods, minimal operator intervention is needed for daily sample analysis after online applications are set up, so the approach is both labor- and cost-effective. The technique can also minimize errors arising from manual operations, eliminate potential inconsistencies caused by different operators, and provide accessibility of LC/MS/MS applications to laboratories that have minimal analytical expertise. [Pg.280]

Step 5 Off-line method or analyzer development and validation This step is simply standard analytical chemistry method development. For an analyzer that is to be used off-line, the method development work is generally done in an R D or analytical lab and then the analyzer is moved to where it will be used (QA/QC lab, at-line manufacturing lab, etc.). For an analyzer that is to be used on-line, it may be possible to calibrate the analyzer off-line in a lab, or pseudo-on-line in a lab reactor or a semi-works unit, and then move the analyzer to its on-line process location. Often, however, the on-line analyzer will need to be calibrated (or re-calibrated) once it is in place (see Step 7). Offline method development and validation generally includes method development and optimization, identification of appropriate check samples, method validation, and written documentation. Again, the form of the documentation (often called the method or the procedure ) is company-specific, but it typically includes principles behind the method, equipment needed, safety precautions, procedure steps, and validation results (method accuracy, precision, etc.). It is also useful to document here what approaches did not work, for the benefit of future workers. [Pg.395]

The proposed strategies for stabilization of gas-lifted oil wells are offline methods which are unable to track online dynamic changes of the system. However, system parameters such as flow rate of injected gas and also noise characteristic are not constant with respect to time. An adaptive Linear Quadratic Gaussian (LQG) approach is presented in this paper in which the state estimation is performed using an Adaptive Unscented Kalman Filter (AUKF) to deal with unknown time-varying noise statistics. State-feedback gain is adaptively calculated based on Linear Quadratic Regulator (LQR). Finally, the proposed control scheme is evaluated on a simulation case study. [Pg.381]

Nanoaerosol can be sampled on a filter or grid for offline analyses of the morphology and composition of individual particles. The most common offline method is transmission electron microscope (TEM) and energy-dispersive X-ray spectroscopy (EDX). However, the physical and chemical properties may change due to agglomeration and/or chemical reactions during the sampling, transport, and offline characterization processes. [Pg.2339]

A column chromatographic offline method for the separation of inorganic from organic mercury species is described by May et al. [110]. The concentration of organomercury can be detected in the eluate, e.g., by flow injection CV-AAS [111]. [Pg.490]

In this chapter we will consider onhne and offline methods to measure the conversion. We will describe methods to determine the molar mass and the molar-mass distribution (MMD) of polymers, to determine the chemical composition and the chemical-composition distribution (CCD) and to determine two-dimensional distributions. [Pg.160]

To evaluate the VIGRAL method, we scanned steel blocks with simulated flaws using a Flexilrak and a upi-50 instrument. This system allows for rapid and accurate acquisition of the desired data, including the A-scan, B-scan, and C-scan data, and serves to evaluate, offline, the V-scan image (Figure 8). [Pg.168]

With this method, levels of 0.1 p.g 1 can be detected in ground water and, if an offline liquid-liquid extraction step is added, levels of 0.1 p.g 1 can be detected (48). [Pg.346]

Offline cleaning can, and should, be entirely successful, with the simplest methods requiring, say, a 10 or 15% inhibited hydrochloric (muriatic) acid solution that is allowed to soak for some hours before neutralization, flushing, and refilling. Where the waterside deposit analysis reveals complex scales, however, it may be necessary to employ several different cleaning solvents. These solvents are added in a multistep process. [Pg.629]

Offline-surface mediated approach Collect effluent from multiple LCs on surface place surface in MS interface use fast, surface-mediated ionization methods such as MALDI, DESI, etc. to sample effluents... [Pg.139]

Online IS introduction allows loading of samples in the biological matrix without preparation. ISs were introduced online in the quantitation of propranolol and diclofenac in plasma (Alnouti et al. 2006). Plasma samples were loaded into the autosampler without pretreatment. Both the plasma sample (10 /iL) and IS (5 //I. from an IS microreservoir) were aspirated into an injection needle sequentially and injected into the sample loop. After the switching of an injection valve, the mixed solution in the sample loop was loaded into a cartridge containing washing solution for online SPE. The accuracy and precision of the online IS method were comparable (85 to 119% and 2 to 12%, respectively) to values obtained offline (86 to 106% and 2 to 16%, respectively). [Pg.289]

Because the instability of the N-oxide metabolite, which was subjected to decomposition during sample preparation (solvent evaporation during offline SPE), online SPE LC/MS became the method of choice for the application. Hsieh et al. (2004) built a system with two TFC cartridges and one analytical column, and another system with two TFC cartridges and two analytical columns for GLP quantitative bioanalysis of drug candidates. A Turbo C18 (50 x 1.0 mm, 5 /.mi, Cohesive Technologies), an Xterra MS C18 (30 x 2.0 mm, 2.5 /mi), and a guard column were used. Protein precipitation preceded injection. The cycle times for the two systems were 0.8 and 0.4 min. [Pg.292]

Online SPE LC/MS/MS is commonly used for bioanalytical applications in the pharmaceutical industry. Column switching systems and TFC systems are easy to build and control. Sophisticated commercial systems and SPE cartridges are readily available. Compared to offline sample preparation, the online approach can save time and labor. However, the development of online SPE bioanalytical assays remains analyte-dependent. Generic methods can be applied to many analytes. For extremely hydrophobic, hydrophilic, and ionic analytes at normal pH range and analytes with a variety of hydrophobicity and pKa values, analyte-specific methods must be developed. An understanding of the chemistry of the analytes and SPE is critical. [Pg.293]

Inclusion of a second pump for effluent dilution and transfer supports both online and offline MS analysis. As shown above, fraction collection followed by LC/ MS analysis sigmficantly expands the performance characteristics of the FAC method, but the effluent can also be sampled for MALDI-based analysis. Advantages to this method include greater salt tolerance over the electrospray approach, extension to complex mixtures of protein and archiving of the mn. MALDI is generally considered to possess higher peak capadty than electrospray (at least... [Pg.239]


See other pages where Offline methods is mentioned: [Pg.27]    [Pg.19]    [Pg.390]    [Pg.304]    [Pg.418]    [Pg.11]    [Pg.328]    [Pg.2625]    [Pg.1697]    [Pg.658]    [Pg.344]    [Pg.417]    [Pg.235]    [Pg.27]    [Pg.19]    [Pg.390]    [Pg.304]    [Pg.418]    [Pg.11]    [Pg.328]    [Pg.2625]    [Pg.1697]    [Pg.658]    [Pg.344]    [Pg.417]    [Pg.235]    [Pg.431]    [Pg.529]    [Pg.71]    [Pg.366]    [Pg.114]    [Pg.156]    [Pg.226]    [Pg.320]    [Pg.329]    [Pg.142]    [Pg.20]    [Pg.2]    [Pg.423]    [Pg.424]    [Pg.352]    [Pg.373]    [Pg.262]    [Pg.118]    [Pg.2]    [Pg.43]    [Pg.241]    [Pg.346]    [Pg.96]   