Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Equipment, analytical

A tandem mass spectrometer must be equipped with an electrospray source and is plumbed as in Fig. 4. LC-pump and an appropriate LC autosampler are used for solvent delivery and automated sample introduction. The mobile phase is acetoni-trile water mixture (80 20, v/v) with 0.05% formic acid at a flow rate of 60 (xL/min. The autosampler is programmed to inject a volume of 40 p,L of the sample. [Pg.351]


X-ray fluorescence (XRF) analysis is successfully used to determine chemical composition of various geological and ecological materials. It is known that XRF analysis has a high productivity, acceptable accuracy of results, developed theory and industrial analytical equipment sets. Therefore the complex methods of XRF analysis have to be constituent part of basis data used in ecological and geochemical investigations... [Pg.234]

The principle of insignificancy , enabling use of the given principle for any level of probability is substantiated. The systematic application of the given principle results in developing metrological criteria for pharmaceutical reference substance, analytical validation, evaluation of results of interlaboratory testing and suitability of the analytical equipment for the phamiaceutical analysis. [Pg.349]

Short-chain and low molecular weight organic acids, such as acetic acid and formic acid, can be formed by certain bacteria. The resulting organic acid salts are not easily detected without specialized analytical equipment in a laboratory. [Pg.137]

The methods that have been discussed require specially designed instruments. Laboratories without such instruments can measure these gases using general-purpose chemical analytical equipment. A compendium of methods for these laboratories is the "Manual on Methods of Air Sampling and Analysis"published by the American Public Health Association. (10). [Pg.203]

Analytical methods available to labbratories with only general-purpose analytical equipment may be found in the "Methods of Air Sampling and Analysis" cited at the end of the previous section. [Pg.206]

Not only the buildings themselves, but an allowance for equipment and stocks within the buildings must be included in the cost estimates, such as maintenance shop power equipment, control laboratory analytical equipment and reagents and, largest of all, the thousands of warehouse equipment spares, fittings, and supplies. For feasibility cost estimates, such items are factored from experience. [Pg.229]

Surface and Thin Film Analytical Equipment Suppliers... [Pg.295]

Many companies now supply surface and thin film analytical equipment although a few provide several techniques, most specialize in just one or two. (Only suppliers of the equipment which is discussed in more detail are given in the list helow. The authors cannot guarantee completeness.)... [Pg.295]

Finally, analytical equipment was used for characterisation, such as XRD, SEM, TEM, LM and light scattering. These were available either in the School of Chemical Engineering or other departments and research centres in the Universiti Sains Malaysia. However, owing to limited access to the high-end analytical equipment to analyse the membrane, the surface morphology of the membrane and the porous ceramic support was only characterised with SEM and LM. [Pg.387]

The resolution of the ToF analyser is dependent upon the ability to measure the very small differences in time required for ions of a similar m/z to reach the detector. Increasing the distance that the ions travel between source and detector, i.e. increasing the length of the flight tube, would accentuate any such small time-differences. The implication of such an increase is that the instrument would be physically larger and this goes against the current trend towards the miniaturization of all analytical equipment. [Pg.62]

While it is true that in many cases the quality of data acquired during analysis is directly proportional to the quality of the result that may be obtained, it is also true that in many cases the power of modem computer systems attached to analytical equipment of all sorts can be nsed to provide better results than might be thought possible from a cursory examination of the raw data. Even when chromatography is used to separate the components of a mixture and simplify the job of the analyst, the computer may still allow information hidden in the vast amount of data generated to be extracted. [Pg.74]

All results are clipped to a specific number of digits to simulate the operation of digital read-outs of analytical equipment p is the precision, d is dimension, and a is the superimposed ND(0, a ) noise in Table 4.26. [Pg.251]

Quality of analytical equipment specificity, accuracy, precision, and sensitivity of measuring and analyzing equipment determine the reliability of test results. [Pg.556]

Determination of appropriate measuring and analysis methods. Decisions must be made on the selection of appropriate and available measuring and or analytical equipment and tools. The characteristics of the methods must be discussed in terms of specificity, accuracy, precision, sensitivity of the methods, and locations of measuring and/or sampling (off-line, at-line, on-line, in-line, non-invasive). [Pg.561]

Even with the development of high-throughput analytical equipment, the discovery phase still requires a significant investment of time and resources. Future trends will likely focus on increasing the number of available dehydrogenases and cutting the time and effort needed to screen them. [Pg.295]

In the n-paraffin reactions, let us suggest that the reaction scheme shown in Figure 6 satisfies most of the observations. The solid lines represent reactions that have been observed, while the dashed lines are proposed reactions involving products whose steady state concentrations are too small to be measured with our analytical equipment. [Pg.94]

For catalyst testing, conventional small tubular reactors are commonly employed today [2]. However, although the reactors are small, this is not the case for their environment. Large panels of complex fluidic handling manifolds, containment vessels, and extended analytical equipment encompass the tube reactors. Detection is often the bottleneck, since it is still performed in a serial fashion. To overcome this situation, there is the vision, ultimately, to develop PC-card-sized chip systems with integrated microfluidic, sensor, control, and reaction components [2]. The advantages are less space, reduced waste, and fewer utilities. [Pg.51]

Stability tests of catalyst. All catalysts deactivate during their life by various causes (see Chapter 3). The aim of stability tests is to examine the cause and rate of deactivation. These experiments are usually performed at conditions similar to those planned for the commercial unit. In some cases, accelerated tests are carried out using a feedstock with an elevated level of impurities or at a temperature significantly higher than that anticipated for the full-scale reactor. A laboratory reactor used for such tests is usually a down-scaled reactor or a part of the full-scale-reactor. Standard analytical equipment is used. [Pg.293]

These installations of on-line process analytical equipment operated over extended periods of time with the high degree of dependability required in the process environment. Considerable cost savings in process development time were achieved through automation of analysis. [Pg.78]

Any attempt to give an up-to-date account of physical methods of chemical analysis of materials must suffer from the problem of aiming at a moving target. In the chapters which follow I have attempted to illustrate the selected techniques with examples taken from the recent literature of the subject. However I am aware that there is constant instrument development and improvement, so that what follows is at best only a description of analytical equipment that is commercially available at the present time. [Pg.224]


See other pages where Equipment, analytical is mentioned: [Pg.58]    [Pg.419]    [Pg.79]    [Pg.200]    [Pg.49]    [Pg.18]    [Pg.56]    [Pg.200]    [Pg.127]    [Pg.248]    [Pg.538]    [Pg.145]    [Pg.22]    [Pg.292]    [Pg.514]    [Pg.536]    [Pg.537]    [Pg.42]    [Pg.162]    [Pg.726]   
See also in sourсe #XX -- [ Pg.325 ]

See also in sourсe #XX -- [ Pg.236 ]

See also in sourсe #XX -- [ Pg.484 ]




SEARCH



© 2024 chempedia.info