Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

INDEX preventative methods

The evaluation methods could be direct, e.g., measuring a containment index, or indirect, e.g., measuring pressure loss or velocity distribution. The direct methods are used to measure the performance of a hood or an inlet during periodic preventive maintenance. Indirect methods are used for verifying or checking on a daily basis (routine checks). How often each method is used depends on the availability of instrumentation and qualified personnel, since direct measurement of a hood s performance can be both expensive and difficult. On the other hand, indirect methods are usually easier to use and can sometimes include inexpensive, continuously monitoring instruments (pressure gauges or velocity indicators). [Pg.1012]

Figure 9.2 displays a division of the mass range into 13 intervals. After multiplication of all the individual normalized correlation values, the composite correlation index is smaller and the method achieves more selectivity than it would if a single correlation function were calculated over the full mass range. A lower limit of 0.0001 was placed on the value for each normalized interval comparison to prevent the method from generating absurdly low values. These... [Pg.186]

In the Mond Index the plant is divided into individual units on the basis of the feasibility of creating separating barriers. One of the factors taken into account in the index is therefore plant layout. The potential hazard is expressed in terms of the initial value of a set of indices for fire, explosion and toxicity. A hazard factor review is then carried out to see if design changes reduce the hazard, and intermediate values of the indices are determined. Offsetting factors for preventative and protective features are applied and the final values of the indices, or offset indices, are calculated. The elements of the Mond method are listed in Table 1. [Pg.23]

Oil (Aa 4-38) determines oil content in a dried sample of oil-bearing material by extraction with petroleum ether. This method is specific for cottonseed, which first must be fumed with hydrochloric acid to prevent oil adsorption to the fiber. Additional methods exist for other oilseeds. Oxygen Stability Index (OSI) (Cd 12b-92) measures the oxidation induction period of fat sample (essentially the time for a sample to exhaust its antioxidant properties) under conditions of the test. [Pg.1649]

The safety and loss prevention guide developed by the Dow Chemical Company provides a method for evaluating the potential hazards of a process and assessing the safety and loss-prevention measures needed. In this procedure, a numerical Fire and Explosion Index is calculated, based on the nature of the process and the properties of the materials. The index can be used two different ways. In the preliminary design, the Dow index will indicate whether alternative,... [Pg.70]

There are two other types of technologies—reverse osmosis (RO) and electrodeionization (EDI)—that remove dissolved solids from a liquid stream. Both are widely used in the water purification industry and have potential for use in the treatment of CMP wastewater. RO is a method by which water is forced through a semipermeable membrane that does not allow ions to cross. EDI removes ions from a liquid stream by means of an applied voltage. Both the EDI or RO are very effective in removing anions and cations, but the tradeoff is that the feed to the EDI or RO must be preconditioned to prevent damage to the equipment. In particular, the feedwater to an RO should not have a silt density index (SDI) greater than 3.0, which may require additional filtration to ensure all the solids are removed from the liquid stream. Some EDI manufacturers recommend that the feedwater to the EDI be RO permeate or of better quality. [Pg.642]

Early in the development of cisplatin, more than 70% of patients developed acute renal failure that appeared to be cisplatin dose-related [34, 35]. Despite aggressive hydration, especially with NaCl solutions, which are routinely apphed in the clinical setting to prevent nephrotoxicity [36], renal failure still occurs [37,38,39]. Therefore several attempts have been made to reduce nephrotoxicity by either co administration of other compounds, alternate method of administration, or by developing analogues with an improved therapeutic index. [Pg.514]

To prevent hot spot occurrence, we evaluated the methods which improved liquid distribution, in the commercial operations. Figure 6 compares changes in the temperature deviation of the first bed during the different runs. The axial number, which is an average of the standard deviation of the temperatures at each level, is defined as an index of a degree of maldistribution. A small number indicates good liquid distribution. We took the countermeasures successively run after run. [Pg.151]


See other pages where INDEX preventative methods is mentioned: [Pg.11]    [Pg.735]    [Pg.685]    [Pg.674]    [Pg.4]    [Pg.874]    [Pg.635]    [Pg.283]    [Pg.450]    [Pg.67]    [Pg.147]    [Pg.475]    [Pg.310]    [Pg.182]    [Pg.213]    [Pg.142]    [Pg.259]    [Pg.34]    [Pg.87]    [Pg.53]    [Pg.155]    [Pg.1]    [Pg.7]    [Pg.188]    [Pg.395]    [Pg.50]    [Pg.2257]    [Pg.153]    [Pg.468]    [Pg.234]    [Pg.134]    [Pg.77]    [Pg.200]    [Pg.108]    [Pg.519]    [Pg.179]    [Pg.1073]    [Pg.1136]   
See also in sourсe #XX -- [ Pg.936 ]




SEARCH



INDEX prevention

Preventive Methods

© 2024 chempedia.info