Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Enantiomeric selectors

Recently, several new GAGs have been investigated as chiral selectors Dermatan sulfate has been successfully demonstrated to act as an enantiomeric selector for a variety of basic drugs, such as /3-sympatho-mimetics, /3-blockers, and antihypertensives (82). More recently, pentosan polysulfate was also investigated as a chiral selector for tryptophan derivatives and several drugs (83). [Pg.296]

Silica-base stationary phases have also been employed for enantiomeric separations in CEC [6,72-81]. In the initial work on chiral CEC, commercially available HPLC materials were utilized, including cyclodextrins [6,74,81] and protein-type selectors [73,75,80] such as human serum albumin [75] and ai-acid glycoprotein [73]. Fig. 4.9, for example, depicts the structure of a cyclodextrin-base stationary phase used in CEC and the separation of mephobarbital enantiomers by capillary LC and CEC in a capillary column packed with such a phase. The column operated in the CEC mode affords higher separation efficiency than in the capillary LC mode. Other enantiomeric selectors are also use in CEC, including the silica-linked or silica-coated macrocyclic antibiotics vancomycin [82,83] and teicoplanin [84], cyclodextrin-base polymer coated silicas [72,78], and weak anion-exchage type chiral phases [85]. Relatively high separation efficiency and excellent resolution for a variety of compounds have also been achieved using columns packed with naproxen-derived and Whelk-0 chiral stationary phases linked to 3 pm silica particles [79]. Fig. 4.10 shows the... [Pg.133]

Recently, two examples of the separation of enantiomers using CCC have been published (Fig. 1-2). The complete enantiomeric separation of commercial d,l-kynurenine (2) with bovine serum albumin (BSA) as a chiral selector in an aqueous-aqueous polymer phase system was achieved within 3.5 h [128]. Moreover, the chiral resolution of 100 mg of an estrogen receptor partial agonist (7-DMO, 3) was performed using a sulfated (3-cyclodextrin [129, 130], while previous attempts with unsubstituted cyclodextrin were not successful [124]. The same authors described the partial resolution of a glucose-6-phosphatase inhibitor (4) with a Whelk-0 derivative as chiral selector (5) [129]. [Pg.11]

Several chiral selectors have been used in the separation of enantiomers by distillation [198]. Among them, the bisalcohol 8 (Fig. 1-6) has permitted obtainment of the ketone (+)-9 with an enantiomeric excess of 95 %. This example shows the feasibility of the process even though, in this particular case, the price of the chiral selector might prohibit scale-up of the separation. [Pg.17]

All enantioselective separation techniques are based on submitting the enantiomeric mixture to be resolved to a chiral environment. This environment is usually created by the presence of a chiral selector able to interact with both enantiomers of the mixture, albeit with different affinities. These differences in the enantiomer-selector association will finally result in the separation that is sought. [Pg.18]

Enantiomeric separations have become increasingly important, especially in the pharmaceutical and agricultural industries as optical isomers often possess different biological properties. The analysis and preparation of a pure enantiomer usually involves its resolution from the antipode. Among all the chiral separation techniques, HPLC has proven to be the most convenient, reproducible and widely applicable method. Most of the HPLC methods employ a chiral selector as the chiral stationary phase (CSP). [Pg.24]

To find the most efficient selectors in the library, blue and red dye-labeled enantiomeric probe molecules 6 and 7 were prepared by linking pentafluorophenyl esters of L- and D-proline with Disperse Blue 3 and Disperse Red 1, respectively, through an isophthaloyl (shown in structures 6 and 7) or a succinyl moiety. Eor detection, a... [Pg.69]

In the next step, the best candidate from the series 2-oxo-4-(9-phenanthryl)-dihy-dropyrimidine 22 was prepared and isolated in enantiomerically pure form, then attached to a macroporous polymer support. To attach the isolated selector to the amino functionalized macroporous polymethacrylate support, a suitable reactive handle had to be introduced into the dihydropyrimidine. We chose to functionalize the methyl group at the C6 carbon atom by a simple bromination to afford (-)-22. Coupling of this compound to the amino functionalized support then gave the desired chiral stationary phase CSP 12 (Scheme 3-6) containing 0.20 mmol g of the selector. [Pg.82]

Our group also demonstrated another combinatorial approach in which a CSP carrying a library of enantiomerically pure potential selectors was used directly to screen for enantioselectivity in the HPLC separation of target analytes [93, 94]. The best selector of the bound mixture for the desired separation was then identified in a few deconvolution steps. As a result of the parallelism advantage , the number of columns that had to be screened in this deconvolution process to identify the single most selective selector CSP was much smaller than the number of actual selectors in the library. [Pg.85]

Mourier s report was quickly followed by successful enantiomeric resolutions on stationary phases bearing other types of chiral selectors, including native and deriva-tized cyclodextrins and derivatized polysaccharides. Many chiral compounds of pharmaceutical interest have now been resolved by packed column SFC, including antimalarials, (3-blockers, and antivirals. A summary is provided in Table 12-2. Most of the applications have utilized modified CO, as the eluent. [Pg.303]

Mixing the additive in the eluent used as a mobile phase can also modify the chromatographic system (dynamic modification), but the use of modified adsorbents has led to an improvement of resolution. Example works include that by Armstrong and Zhou [11], who used a macrocyclic antibiotic as the chiral selector for enantiomeric separations of acids, racemic drugs, and dansyl amino acid on biphenyl-bonded silica. [Pg.202]

In another study, the authors reported a comparative study of the enantiomeric resolution of miconazole and the other two chiral drugs by high performance liquid chromatography on various cellulose chiral columns in the normal phase mode [79], The chiral resolution of the three drugs on the columns containing different cellulose derivatives namely Chiralcel OD, OJ, OB, OK, OC, and OE in normal phase mode was described. The mobile phase used was hexane-isopropanol-diethylamine (425 74 1). The flow rates of the mobile phase used were 0.5, 1, and 1.5 mL/min. The values of the separation factor (a) of the resolved enantiomers of econazole, miconazole, and sulconazole on chiral phases were ranged from 1.07 to 2.5 while the values of resolution factors (Rs) varied from 0.17 to 3.9. The chiral recognition mechanisms between the analytes and the chiral selectors are discussed. [Pg.52]

The chiral purity of amino acids at large enantiomeric excess can be determined automatically by derivatization with 4-fluoro-7-nitro-2,l,3-benzoxadiazole (127b) followed by CE with cyclodextrin chiral selectors and detection of the LIF excitation at 488 nm. Lod 140 ppm of L-phenylalanine in D-phenylalanine324. [Pg.1094]

In simple experiments, particulate silica-supported CSPs having various cin-chonan carbamate selectors immobilized to the surface were employed in an enantioselective liquid-solid batch extraction process for the enantioselective enrichment of the weak binding enantiomer of amino acid derivatives in the liquid phase (methanol-0.1M ammonium acetate buffer pH 6) and the stronger binding enantiomer in the solid phase [64]. For example, when a CSP with the 6>-9-(tcrt-butylcarbamoyl)-6 -neopentoxy-cinchonidine selector was employed at an about 10-fold molar excess as related to the DNB-Leu selectand which was dissolved as a racemate in the liquid phase specified earlier, an enantiomeric excess of 89% could be measured in the supernatant after a single extraction step (i.e., a single equilibration step). This corresponds to an enantioselectivity factor of 17.7 (a-value in HPLC amounted to 31.7). Such a batch extraction method could serve as enrichment technique in hybrid processes such as in combination with, for example, crystallization. In the presented study, it was however used for screening of the enantiomer separation power of a series of CSPs. [Pg.94]

For the given systems (ionizable selectors and solutes), a modified form of CPC was usually more favorable The so-called pH-zone-refining CPC mode, which is a kind of displacement type of chromatography. In this mode, the column is filled with the acidified stationary phase (e.g., using TFA as retainer), then injection of the sample takes place before the rotor is switched on and elution is started with a basic mobile phase (e.g., using ammonia as displacer in the aqueous mobile phase). Apparent pH and enantiomeric composition were determined for every fraction. It appeared that the enantiomers eluted in refined... [Pg.99]

Unusual amino acids include a class of unnatural a-amino acids such as phenylalanine, tyrosine, alanine, tryptophan, and glycine analogs, and f)-amino acid analogs containing 1,2,3,4-tetrahydroisoquinoline, tetraline, l,2,3,4-tetrahydro-2-carboline, cyclopentane, cyclohexane, cyclohexene, bicyclo[2.2.1]heptane or heptene skeletons. Different selectors were exploited for the separation of unusual amino acids, most of the production being made by Peter and coworkers teicoplanin [41, 56, 84, 90, 93, 124, 141-144], ristocetin A [33, 94, 145, 146], and TAG [56, 147]. Enantiomeric and diastereomeric separations of cyclic -substituted a-amino acids were reported by other authors on a teicoplanin CSP [88, 89], Ester and amide derivatives of tryptophan and phenylalanine were recently analyzed on a Me-TAG CSP [58],... [Pg.141]

Aboul-Enein, H.Y. and Ali, I., Macrocyclic antibiotics as effective chiral selectors for enantiomeric resolntion by liquid chromatography and capillary electrophoresis, Chromatographia, 52, 679, 2000. [Pg.161]

Ward, T.J., Dann III, C., and Blaylock, A., Enantiomeric resolution using the macrocyclic antibiotics rifamycin B and rifamycin SV as chiral selectors for capillary electrophoresis, J. Chromatogr. A, 715, 337, 1995. [Pg.161]

Ramos, L. et al., Liquid chromatographic/atmospheric pressure chemical ionization tandem mass spectrometry enantiomeric separation of DL-fhreo-methylphenidate (Ritalin ) using a macrocyclic antibiotic as the chiral selector. Rapid Commun. Mass Spectrom., 13, 2054, 1999. [Pg.167]

Ekborg-Ott, K.H., Wang, X., and Armstrong, D.W., Effect of selector coverage and mobile phase composition on enantiomeric separations with ristocetin A chiral stationary phases, Microchem. J., 62, 26, 1999. [Pg.168]

Chiral separation of drng molecules and of their precursors, in the case of synthesis of enantiomerically pure drugs, is one of the important application areas of HPLC in pharmaceutical analysis. Besides HPLC, capillary electrophoresis (CE) is another technique of choice for chiral separations. Chapter 18 provides an overview of the different modes (e.g., direct and indirect ones) of obtaining a chiral separation in HPLC and CE. The direct approaches, i.e., those where the compound of interest is not derivatized prior to separation, are discussed in more detail since they are cnrrently the most frequently used techniques. These approaches require the use of the so-called chiral selectors to enable enantioselective recognition and enantiomeric separation. Many different molecnles have been nsed as chiral selectors, both in HPLC and CE. They can be classified into three different groups, based on their... [Pg.12]


See other pages where Enantiomeric selectors is mentioned: [Pg.64]    [Pg.244]    [Pg.4]    [Pg.70]    [Pg.77]    [Pg.146]    [Pg.170]    [Pg.299]    [Pg.201]    [Pg.19]    [Pg.84]    [Pg.91]    [Pg.158]    [Pg.182]    [Pg.309]    [Pg.329]    [Pg.154]    [Pg.81]    [Pg.90]    [Pg.192]    [Pg.448]   
See also in sourсe #XX -- [ Pg.57 ]

See also in sourсe #XX -- [ Pg.57 ]




SEARCH



Selectors

© 2024 chempedia.info