Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chiral selector

Chiral resolution in GC is carried out using chiral stationary phases (CSPs) that is, GC columns containing chiral compounds. Many chiral compounds are used for the preparation of chiral stationary phases. The most commonly used chiral compounds are cyclodextrins (CD) and their derivatives. The merit of CD derivatives for chiral resolution in GC is the great spectmm of resolvable classes of compounds. The modified CDs are capable of resolving chiral pollutants over a high range of GC temperatures. [Pg.186]

CDs as chiral selectors in the gas and liquid chromatographic separations of enantiomers has become a subject of interest over the past two decades. The presence of the chiral hollow basket/cavity of these molecules makes them suitable for chiral resolution of a wide range of racemic compounds. At present, the use of CDs as chiral selectors for enantiomeric resolution by gas chromatography is very common. As chiral selectors, CDs have been used in the form of chiral stationary phases (CSPs). [Pg.187]


In this experiment the enantiomers of cyclobarbital and thiopental, and phenobarbital are separated using MEKC with cyclodextran as a chiral selector. By adjusting the pH of the buffer solution and the concentration and type of cyclodextran, students are able to find conditions in which the enantiomers of cyclobarbital and thiopental are resolved. [Pg.614]

Traditionally, chiral separations have been considered among the most difficult of all separations. Conventional separation techniques, such as distillation, Hquid—Hquid extraction, or even some forms of chromatography, are usually based on differences in analyte solubiUties or vapor pressures. However, in an achiral environment, enantiomers or optical isomers have identical physical and chemical properties. The general approach, then, is to create a "chiral environment" to achieve the desired chiral separation and requires chiral analyte—chiral selector interactions with more specificity than is obtainable with conventional techniques. [Pg.60]

An alternative model has been proposed in which the chiral mobile-phase additive is thought to modify the conventional, achiral stationary phase in situ thus, dynamically generating a chiral stationary phase. In this case, the enantioseparation is governed by the differences in the association between the enantiomers and the chiral selector in the stationary phase. [Pg.61]

Most chiral chromatographic separations are accompHshed using chromatographic stationary phases that incorporate a chiral selector. The chiral separation mechanisms are generally thought to involve the formation of transient diastereomeric complexes between the enantiomers and the stationary phase chiral ligand. Differences in the stabiHties of these complexes account for the differences in the retention observed for the two enantiomers. Often, the use of a... [Pg.61]

Thin-Layer Chromatography. Chiral stationary phases have been used less extensively in tic as in high performance Hquid chromatography (hplc). This may, in large part, be due to lack of avakabiHty. The cost of many chiral selectors, as well as the accessibiHty and success of chiral additives, may have inhibited widespread commerciali2ation. Usually, nondestmctive visuali2ation of the sample spots in tic is accompHshed using iodine vapor, uv or fluorescence. However, the presence of the chiral selector in the stationary phase can mask the analyte and interfere with detection (43). [Pg.62]

Chiral stationary phases in tic have been primarily limited to phases based on normal or microcrystalline cellulose (44,45), triacetylceUulose sorbents or siHca-based sorbents that have been chemically modified (46) or physically coated to incorporate chiral selectors such as amino acids (47,48) or macrocyclic antibiotics (49) into the stationary phase. [Pg.62]

Fig. 4. A ligand-exchange chiral selector complexed with a chiral analyte. Fig. 4. A ligand-exchange chiral selector complexed with a chiral analyte.
Column chiral selector Typical mobile phase conditions Typical analyte features required... [Pg.63]

Fig. 5. The stmcture of the chiral selector in the Whelk-O-1 chiral stationary phase. Fig. 5. The stmcture of the chiral selector in the Whelk-O-1 chiral stationary phase.
Diamide Chiral Separations. The first chiral stationary phase for gas chromatography was reported by GH-Av and co-workers in 1966 (113) and was based on A/-trifluoroacetyl (A/-TFA) L-isoleucine lauryl ester coated on an inert packing material. It was used to resolve the tritiuoroacetylated derivatives of amino acids. Related chiral selectors used by other workers included -dodecanoyl-L-valine-/-butylamide and... [Pg.70]

The chiral recognition mechanism for these types of phases was attributed primarily to hydrogen bonding and dipole—dipole interactions between the analyte and the chiral selector in the stationary phase. It was postulated that chiral recognition involved the formation of transient five- and seven-membered association complexes between the analyte and the chiral selector (117). [Pg.70]

Catechin and epicatechin are two flavanols of the catechin family. They are enantiomers. The capillary zone electrophoresis (CE) methods with UV-detection were developed for quantitative determination of this flavanols in green tea extracts. For this purpose following conditions were varied mnning buffers, pH and concentration of chiral additive (P-cyclodextrin was chosen as a chiral selector). Borate buffers improve selectivity of separation because borate can make complexes with ortho-dihydroxy groups on the flavanoid nucleus. [Pg.114]

It is in the study of this phenomenon where two-dimensional GC offers by far the most superior method of analysis. The use of chiral selector stationary phases, in particular modified cyclodextrin types, allows apolar primary and atropisomer selective secondary separation. Reported two-dimensional methods have been successful... [Pg.69]

Packing name Chiral selector (semi)preparative reference of the... [Pg.6]

The type of CSPs used have to fulfil the same requirements (resistance, loadabil-ity) as do classical chiral HPLC separations at preparative level [99], although different particle size silica supports are sometimes needed [10]. Again, to date the polysaccharide-derived CSPs have been the most studied in SMB systems, and a large number of racemic compounds have been successfully resolved in this way [95-98, 100-108]. Nevertheless, some applications can also be found with CSPs derived from polyacrylamides [11], Pirkle-type chiral selectors [10] and cyclodextrin derivatives [109]. A system to evaporate the collected fractions and to recover and recycle solvent is sometimes coupled to the SMB. In this context the application of the technique to gas can be advantageous in some cases because this part of the process can be omitted [109]. [Pg.8]

From the pioneering studies of Ito et al. [117], CCC has been mainly used for the separation and purification of natural products, where it has found a large number of applications [114, 116, 118, 119]. Moreover, the potential of this technique for preparative purposes can be also applied to chiral separations. The resolution of enantiomers can be simply envisaged by addition of a chiral selector to the stationary liquid phase. The mixture of enantiomers would come into contact with this liquid CSP, and enantiodiscrimination might be achieved. However, as yet few examples have been described in the literature. [Pg.10]

The first partial chiral resolution reported in CCC dates from 1982 [120]. The separation of the two enantiomers of norephedrine was partially achieved, in almost 4 days, using (/ ,/ )-di-5-nonyltartrate as a chiral selector in the organic stationary phase. In 1984, the complete resolution of d,l-isoleucine was described, with N-dodecyl-L-proline as a selector in a two-phase buffered n-butanol/water system containing a copper (II) salt, in approximately 2 days [121]. A few partial resolutions of amino acids and dmg enantiomers with proteic selectors were also published [122, 123]. [Pg.10]

However, it was not until the beginning of 1994 that a rapid (<1.5 h) total resolution of two pairs of racemic amino acid derivatives with a CPC device was published [124]. The chiral selector was A-dodecanoyl-L-proline-3,5-dimethylanilide (1) and the system of solvents used was constituted by a mixture of heptane/ethyl acetate/methanol/water (3 1 3 1). Although the amounts of sample resolved were small (2 ml of a 10 inM solution of the amino acid derivatives), this separation demonstrated the feasibility and the potential of the technique for chiral separations. Thus, a number of publications appeared subsequently. Firstly, the same chiral selector was utilized for the resolution of 1 g of ( )-A-(3,5-dinitrobenzoyl)leucine with a modified system of solvents, where the substitution of water by an acidified solution... [Pg.10]

Recently, two examples of the separation of enantiomers using CCC have been published (Fig. 1-2). The complete enantiomeric separation of commercial d,l-kynurenine (2) with bovine serum albumin (BSA) as a chiral selector in an aqueous-aqueous polymer phase system was achieved within 3.5 h [128]. Moreover, the chiral resolution of 100 mg of an estrogen receptor partial agonist (7-DMO, 3) was performed using a sulfated (3-cyclodextrin [129, 130], while previous attempts with unsubstituted cyclodextrin were not successful [124]. The same authors described the partial resolution of a glucose-6-phosphatase inhibitor (4) with a Whelk-0 derivative as chiral selector (5) [129]. [Pg.11]

Examples with other Pirkle-type CSPs have also been described [139, 140]. In relation to polysaccharides coated onto silica gel, they have shown long-term stability in this operation mode [141, 142], and thus are also potentially good chiral selectors for preparative SFC [21]. In that context, the separation of racemic gliben-clamide analogues (7, Fig. 1-3) on cellulose- and amylose-derived CSPs was described [143]. [Pg.12]

Gas chromatography (GC) has also been used for preparative purposes, but is restricted to relatively volatile racemates such as anesthetics, pheromones or monoterpenes and, therefore, very few applications are reported. Nevertheless, in the cases to which GC may be applied, it could be considered as an economical alternative to HPLC. Most of the resolutions of enantiomers were performed on cyclodex-trin-derived CSPs [109, 144-153], and only on very few occasions were other chiral selectors used [153]. [Pg.13]

The first successful chiral resolutions through enantioselective membranes have been published recently, but few cases are applicable to the preparative scale, mainly due to mechanical and technical limitations. Low flow rates, saturation of the chiral selectors and loss of enantioselectivity with time are some of the common problems encountered and that should be solved in the near future. [Pg.13]

Liquid membranes can be constituted by liquid chiral selectors used directly [170] or by solutions of the chiral molecules in polar or apolar solvents. This later possibility can also be an advantage since it allows the modulation of the separation con-... [Pg.14]


See other pages where Chiral selector is mentioned: [Pg.60]    [Pg.60]    [Pg.61]    [Pg.61]    [Pg.61]    [Pg.62]    [Pg.62]    [Pg.62]    [Pg.63]    [Pg.63]    [Pg.63]    [Pg.63]    [Pg.64]    [Pg.66]    [Pg.66]    [Pg.67]    [Pg.68]    [Pg.70]    [Pg.70]    [Pg.70]    [Pg.244]    [Pg.4]    [Pg.5]    [Pg.11]    [Pg.14]    [Pg.14]    [Pg.14]    [Pg.14]   
See also in sourсe #XX -- [ Pg.12 , Pg.447 , Pg.448 , Pg.450 , Pg.451 , Pg.454 , Pg.455 , Pg.461 , Pg.466 ]

See also in sourсe #XX -- [ Pg.352 ]

See also in sourсe #XX -- [ Pg.205 , Pg.261 ]

See also in sourсe #XX -- [ Pg.365 ]

See also in sourсe #XX -- [ Pg.209 ]

See also in sourсe #XX -- [ Pg.274 ]

See also in sourсe #XX -- [ Pg.174 ]




SEARCH



Analytes - Negatively Charged Chiral Selectors

Anionic Analytes - Positively Charged Chiral Selectors

Antibiotics glycopeptide chiral selectors

Capacity factors, chiral selectors

Capillary chiral selectors

Capillary electrochromatography, chiral selectors

Capillary electrophoresis chiral selectors

Capillary electrophoresis using chiral selectors

Charged chiral selector

Chiral anion exchange—type selectors

Chiral selector complex

Chiral selectors and enantiomers

Chiral selectors applications

Chiral selectors chromatographic analysis

Chiral selectors chromatography

Chiral selectors classification

Chiral selectors concentration

Chiral selectors cyclodextrins

Chiral selectors enantiomer association

Chiral selectors enantiomers

Chiral selectors high-performance liquid

Chiral selectors in chromatography

Chiral selectors interaction with solute

Chiral selectors mobile phase additives

Chiral selectors polysaccharides

Chiral selectors principles

Chiral selectors proteins

Chiral selectors proteins used

Chiral selectors recognition mechanisms

Chiral selectors separation

Chiral selectors types

Chiral selectors, enantioseparation

Chiral selectors, in capillary electrophoresis

Chirality chiral selectors

Crown chiral selectors

Crown ethers chiral selectors

Cyclodextrins as chiral selectors

Different Classes of Chiral Selectors

Electrophoretic mobility chiral selectors

Glycopeptide chiral selectors

Glycopeptides as chiral selectors

Human serum albumin chiral selectors

Ligand exchange chiral selectors

Macromolecular chiral selectors

Polymeric chiral selectors, enantiomer

Polymeric chiral selectors, enantiomer recognition

Polysaccharides as chiral selectors

Proteins as chiral selectors

Quinidines chiral selectors

Quinine chiral selectors

Selectivity factor, chiral selectors

Selectors

Selectors imprinted chiral phases

Teicoplanin chiral selectors

Thin-layer chromatography, chiral selectors used

Vancomycin chiral selectors

© 2024 chempedia.info