The recovery of caustic from hemiceUulose (qv) ia the rayon process was well estabUshed ia the 1930s (18), and is still used ia modem times (19) (see Pulp). Very few new iadustrial appHcations of dialysis emerged duriag the 1940—1980 period. More recendy, iaterest has reawakened ia isobaric dialysis as a unit operation for the removal of alcohol from beverages (20,21) and ia the production of products derived from biotechnology (22,23). [Pg.33]

The second half of the 1990s saw an increase in the use of dialysis (as a liquid-liquid extraction procedure). Its main advantage is the possibility of operating in an automatic mode by coupling a dialysis unit with an automatic injector, as demonstrated not only in HPLC analysis (17) but also in flow-injection determinations of reducing sugars in wines (18) and alcoholic fermentation broths (19). [Pg.290]

Various membrane operations are available today for a wide spectrum of industrial applications. Microfiltration (MF), ultrafiltration (UF), nanofiltration (NF), reverse osmosis (RO), gas and vapor separation (GS, VS), pervaporation (PV), dialysis (D), electrodialysis (ED) and membrane contactors (MCs) are only some of the best-known membrane unit operations. [Pg.265]

Just as a voyage from one point to another consists of many individual steps, so also does an analytical procedure involve many individual operations. These are often referred to as "unit operations", and they may be classified in several ways (eg. obtaining a sample, getting it ready for analysis, the analysis itself, or the detection step for quantitation). The sample may be solid, liquid, or gas, and its pretreatment could include such operations as extraction, filtration, dialysis, distillation, concentration, or even chromatography. [Pg.15]

The diameter or the radius of the pores is one of the most important geometric characteristic of porous solids. In terms of lUPAC nomenclature, we can have macropores (mean pore size greater than 5 x 10 m), mesopores (between 5 x 10 and 2 x 10 m) and micropores (less than 2 x 10 m). The analysis of species transport inside the porous structure is very important for the detailed description of many unit operations or applications among them we can mention suspension filtration, solid drying and humidification, membrane processes (dialysis, osmosis, gaseous permeation. ), flow in catalytic beds, ion exchange, adsorp-... [Pg.284]

In concept, the operation of the dialysis unit depended on the natural problem of generating a methane flora. Because of this requirement, the two compartments were started initially as a single unit without the membrane in place and operated until a stable response was obtained, indicating good methane production. The units reported on in this paper were all fed twice a day at 9 00 am and 9 00 pm, much as the local waste plant operator would pump sludge twice a day to his digestion equipment. When gas production in the equipment was judged to be normal, the hoses to the dialysis frame were clamped and the membrane inserted. [Pg.112]

Chamberlain, N.S. and Vromen, B.H. Make dialysis part of your unit operations with new acid-resistant membranes. Chem. Eng., 4, 117, 1959. [Pg.979]

The ideal system for sample preparation in a chromatographic method is that the operation of all the steps between sample dissolution and chromatography is done through a SIA technique (Fig.l). The first part of the system will consist of a sample dialysis (unit 1) and the outlet will be channeled into the second unit consisting of concentration or dilution steps and extraction of the analyte. It is always assumed that the concentration, dilution, and derivatization steps can be done by extraction — in most cases, it is absolutely necessary. [Pg.1477]

Various unit operations can be done on line in a reproducible manner in an FIA system such as mixing, dialysis and reactions. Figure 22.3 illustrates a few schematic presentations of experimental set-ups for FIA. [Pg.532]

N. S. Chamberlin and B. H, Vromen, Make Dialysis Part of Your Unit Operations with New... [Pg.979]

Figure 1. Proposed heparin circuit. The extracorporeal device could be a renal dialysis unit or a pump-oxygenator. The heparinase reactor could be part of a blood filter to be used either continuously (in which case heparin would, be added, continuously at the start of the circuit) or at the end of an operation. Heparin could thus be confined to the extracorporeal circuit. Figure 1. Proposed heparin circuit. The extracorporeal device could be a renal dialysis unit or a pump-oxygenator. The heparinase reactor could be part of a blood filter to be used either continuously (in which case heparin would, be added, continuously at the start of the circuit) or at the end of an operation. Heparin could thus be confined to the extracorporeal circuit.
Dialysis (5) as a unit operation considerably antedates gas and liquid permeation. Membrane dialysis was used by Graham in 1861 to separate colloids from crystalloids. The first large industrial dialyzers, for the recovery of caustic from rayon steep liquor, were installed in the United States in the 1930s. Industrial dialysis units for recovery of spent acid from metallurgical liquors have been widely used since 1958. In dialysis, bulk flow of solvent is prevented by balancing the osmotic pressure, and low-molecular-weight solutes are recovered by preferential diffusion across thin membranes having pores of the order of 10 cm. Frequently diffusion is enhanced by application of electric fields. [Pg.405]

Transplant clinic and all operating rooms Delivery rooms and catheter labs Cancer clinics and infusion rooms Bone marrow transplant unit (adult and pediatric) Intensive care units and dialysis units Oncology clinics and transplant units Central supply and sterile processing areas Nursery and neonatal units Food preparation/service areas... [Pg.456]

This part, on applications, covers the following unit operations 8. Evaporation 9. Drying of Process Materials 10. Stage and Continuous Gas-Liquid Separation Processes (humidification, absorption) 11. Vapor-Liquid Separation Processes (distillation) 12. Liquid—Liquid and Fluid-Solid Separation Processes (adsorption, ion exchange, extraction, leaching, crystallization) 13. Membrane Separation Processes (dialysis, gas separation, reverse osmosis, ultrafiltration) 14. Mechanical-Physical Separation Processes (filtration, settling, centrifugal separation, mechanical size reduction). [Pg.934]

A dialysis nurse specializes in assisting patients with kidney disease undergoing dialysis. This requires monitoring the patient before, during, and after dialysis for any complications such as a drop in blood pressure or cramping. The dialysis nurse connects the patient to the dialysis unit via a dialysis catheter that is inserted into the neck or chest, which must be kept clean to prevent infection. A dialysis nurse must have considerable knowledge about how the dialysis machine functions to ensure that it is operating correctly at all times. [Pg.392]

In practice, multichannel manifolds are normally employed in which the sample is injected into an inert flowing carrier and mixing with suitable reagent streams occurs downstream at confluence points. For more complex operations, additional components (such as mixing devices, gas-diffusion/dialysis units, packed columns) can be incorporated in the FIA manifold (McKelvie, 2008 Ruzicka, 2014). [Pg.38]

O Primary peritonitis develops in up to 25% of patients with alcoholic cirrhosis.3 Patients undergoing continuous ambulatory peritoneal dialysis (CAPD) average one episode of peritonitis every 2 years.4 Secondary peritonitis may be caused by perforation of a peptic ulcer traumatic perforation of the stomach, small or large bowel, uterus, or urinary bladder appendicitis pancreatitis diverticulitis bowel infarction inflammatory bowel disease cholecystitis operative contamination of the peritoneum or diseases of the female genital tract such as septic abortion, postoperative uterine infection, endometritis, or salpingitis. Appendicitis is one of the most common causes of intraabdominal infection. In 1998, 278,000 appendectomies were performed in the United States for suspected appendicitis.5... [Pg.1130]

Extracorporeal dialysis Follow equipment manufacturers operating directions. Laboratory samples Add 70 to 150 units per 10 to 20 mL sample of whole blood to prevent coagulation of sample. [Pg.129]


See other pages where Dialysis unit operation is mentioned: [Pg.32]    [Pg.33]    [Pg.170]    [Pg.19]    [Pg.1201]    [Pg.957]    [Pg.966]    [Pg.966]    [Pg.8]    [Pg.451]    [Pg.151]    [Pg.538]    [Pg.957]    [Pg.966]    [Pg.966]    [Pg.45]    [Pg.992]    [Pg.1001]    [Pg.1001]    [Pg.957]    [Pg.966]    [Pg.966]    [Pg.332]    [Pg.7]    [Pg.438]    [Pg.1693]   
See also in sourсe #XX -- [ Pg.966 ]

See also in sourсe #XX -- [ Pg.966 ]

See also in sourсe #XX -- [ Pg.966 ]




SEARCH



Dialysis

Operational unit

Unit operations

© 2024 chempedia.info