Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chemical atomic emission with inductively coupled

The section on Spectroscopy has been retained but with some revisions and expansion. The section includes ultraviolet-visible spectroscopy, fluorescence, infrared and Raman spectroscopy, and X-ray spectrometry. Detection limits are listed for the elements when using flame emission, flame atomic absorption, electrothermal atomic absorption, argon induction coupled plasma, and flame atomic fluorescence. Nuclear magnetic resonance embraces tables for the nuclear properties of the elements, proton chemical shifts and coupling constants, and similar material for carbon-13, boron-11, nitrogen-15, fluorine-19, silicon-19, and phosphoms-31. [Pg.1284]

This multiauthored book aims at highlighting the role played by atomic and mass spectrometry (with particular reference to atomic absorption spectrometry, inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry) in supporting and promoting research and control of foodstuffs and food commodities as regards both essential and potentially toxic chemical elements. The progress made so far in this field is overviewed and emphasis is put on the open problems that require further investment and development in the public and private sectors. [Pg.745]

Whatever the analytical method and the determinand may be, the greatest care should be devoted to the proper selection and use of internal standards, careful preparation of blanks and adequate calibration to avoid serious mistakes. Today the Antarctic investigator has access to a multitude of analytical techniques, the scope, detection power and robustness of which were simply unthinkable only two decades ago. For chemical elements they encompass Atomic Absorption Spectrometry (AAS) [with Flame (F) and Electrothermal Atomization (ETA) and Hydride or Cold Vapor (HG or CV) generation]. Atomic Emission Spectrometry (AES) [with Inductively Coupled Plasma (ICP), Spark (S), Flame (F) and Glow Discharge/Hollow Cathode (HC/GD) emission sources], Atomic Fluorescence Spectrometry (AFS) [with HC/GD, Electrodeless Discharge (ED) and Laser Excitation (LE) sources and with the possibility of resorting to the important Isotope... [Pg.13]

The classical wet-chemical quaUtative identification of chromium is accompHshed by the intense red-violet color that develops when aqueous Cr(VI) reacts with (5)-diphenylcarba2ide under acidic conditions (95). This test is sensitive to 0.003 ppm Cr, and the reagent is also useful for quantitative analysis of trace quantities of Cr (96). Instmmental quaUtative identification is possible using inductively coupled argon plasma—atomic emission spectroscopy... [Pg.140]

The chemical composition of the samples was determined using an inductively Coupled plasma atomic emission spectrometer (ICP-AES) JY 38 from Jobin Yvon. Specific surface area values were determined by BET method using a Micromeritics Instrument Corp. FlowSorb 2300. The basicity of the materials was studied by temperature programmed desorption (TPD) of C02 used as a probe molecule. The equipment was described in a previous work [7]. FTIR spectra of pellets pressed at 2.5xl08 Pa were recorded with a Vector 22 spectrometer from Brucker. The samples were diluted with KBr (lOOmg KBr - 1.5mg of the sample). [Pg.298]

NMR) [24], and Fourier transform-infrared (FT-IR) spectroscopy [25] are commonly applied methods. Analysis using mass spectrometric (MS) techniques has been achieved with gas chromatography-mass spectrometry (GC-MS), with chemical ionisation (Cl) often more informative than conventional electron impact (El) ionisation [26]. For the qualitative and quantitative characterisation of silicone polyether copolymers in particular, SEC, NMR, and FT-IR have also been demonstrated as useful and informative methods [22] and the application of high-temperature GC and inductively coupled plasma-atomic emission spectroscopy (ICP-AES) is also described [5]. [Pg.239]

Chemically pure reagents were used. Cadmium was added as its sulfate salt in concentrations of about 50 ppm. Lanthanides were added as nitrates. For the experiments with other metal ions so-called "black acid from a Nissan-H process was used. In this acid a large number of metal ions were present. To achieve calcium sulfate precipitation two solutions, one consisting of calcium phosphate in phosphoric acid and the other of a phosphoric acid/sulfuric acid mixture, were fed simultaneously in the 1 liter MSMPR crystallizer. The power input by the turbine stirrer was 1 kW/m. The solid content was about 10%. Each experiment was conducted for at least 8 residence times to obtain a steady state. During the experiments lic iid and solid samples were taken for analysis by ICP (Inductively Coupled Plasma spectrometry, based on atomic emission) and/or INAA (Instrumental Neutron Activation Analysis). The solid samples were washed with saturated gypsum solution (3x) and with acetone (3x), and subsequently dried at 30 C. The details of the continuous crystallization experiments are given in ref. [5]. [Pg.384]

In 1C, the election-detection mode is the one based on conductivity measurements of solutions in which the ionic load of the eluent is low, either due to the use of eluents of low specific conductivity, or due to the chemical suppression of the eluent conductivity achieved by proper devices (see further). Nevertheless, there are applications in which this kind of detection is not applicable, e.g., for species with low specific conductivity or for species (metals) that can precipitate during the classical detection with suppression. Among the techniques that can be used as an alternative to conductometric detection, spectrophotometry, amperometry, and spectroscopy (atomic absorption, AA, atomic emission, AE) or spectrometry (inductively coupled plasma-mass spectrometry, ICP-MS, and MS) are those most widely used. Hence, the wide number of techniques available, together with the improvement of stationary phase technology, makes it possible to widen the spectrum of substances analyzable by 1C and to achieve extremely low detection limits. [Pg.406]

A binder—free Na-Y zeolite with Si/Al ratio of 2.29 was obtained from Strem Chemical Co., La,Na—Y and Cs,Na-Y zeolites were prepared by exchanging Na-Y zeolite with LaCls and CsCl solution at room temperature. The percentage of metal ion exchanged in a zeolite has been determinated by Inductively-Coupled-Plasma Atomic Emission Spectroscopy and the number is used as prefix for the samples, e.g., Cs exchanged level of 667. is represented as 66Cs,Na-Y sample. [Pg.124]

Chemical composition of fresh HTs was determined in a Perkin Elmer Mod. OPTIMA 3200 Dual Vision by inductively coupled plasma atomic emission spectrometry (ICP-AES). The crystalline structure of the solids was studied by X-ray diffraction (XRD) using a Siemens D-500 diffractometer equipped with a CuKa radiation source. The average crystal sizes were calculated from the (003) and (110) reflections employing the Debye-Scherrer equation. Textural properties of calcined HTs (at 500°C/4h) were analyzed by N2 adsorption-desorption isotherms on an AUTOSORB-I, prior to analysis the samples were outgassed in vacuum (10 Torr) at 300°C for 5 h. The specific surface areas were calculated by using the Brunauer-... [Pg.58]

A. Lopez-Molinero, O. Mendoza, A. Callizo, P. Chamorro and J. R. Castillo, Chemical vapor generation for sample introduction into inductively coupled plasma atomic emission spectroscopy vaporisation of antimony(III) with bromide. Analyst, 127(10), 2002, 1386-1391. [Pg.143]

HPLC units have been interfaced with a wide range of detection techniques (e.g. spectrophotometry, fluorimetry, refractive index measurement, voltammetry and conductance) but most of them only provide elution rate information. As with other forms of chromatography, for component identification, the retention parameters have to be compared with the behaviour of known chemical species. For organo-metallic species element-specific detectors (such as spectrometers which measure atomic absorption, atomic emission and atomic fluorescence) have proved quite useful. The state-of-the-art HPLC detection system is an inductively coupled plasma/MS unit. HPLC applications (in speciation studies) include determination of metal alkyls and aryls in oils, separation of soluble species of higher molecular weight, and separation of As111, Asv, mono-, di- and trimethyl arsonic acids. There are also procedures for separating mixtures of oxyanions of N, S or P. [Pg.18]

Most chemical agents contain specific elements in common. G and V agents all contain phosphoms and blister agents, like the mustards, contain sulfur or nitrogen. The combustion of these materials yields excited atoms that emit light characteristic of these elements. The emissions are viewed through an interference filter by a photodetector. As an alternative to a flame, low-powered, inductively coupled (or microwave) plasmas have been used as emission sources. These sources have been combined with... [Pg.74]

Water pollution remains a serious problem in the United States and in other industrial countries. The photo shows land left over after strip mining in Belmont County, Ohio. The various water pools shown are contaminated with waste chemicals. The large pool to the right of center contains sulfuric acid. The smaller pools contain manganese and cadmium. Trace metals in contaminated water samples are often determined by a multielement technique such as inductively coupled plasma rnassj spectrometry or inductively coupled plasma atomic emission spectroscopy. Botft these methods are discussed in this chapter. [Pg.839]

The most utilized methods include X-ray fluorescence (XRF), atomic absorption spectroscopy (AAS), activation analysis (AA), optical emission spectroscopy (OES) and inductively coupled plasma (ICP), mass spectroscopy (MS). Less frequently used techniques include ion-selective electrode (ISE), proton induced X-ray emission (PIXE), and ion chromatography (IC). In different laboratories each of these methods may be practiced by using one of several optional approaches or techniques. For instance, activation analysis may involve conventional thermal neutron activation analyses, fast neutron activation analysis, photon activation analysis, prompt gamma activation analysis, or activation analysis with radio chemical separations. X-ray fluorescence options include both wave-length and/or energy dispersive techniques. Atomic absorption spectroscopy options include both conventional flame and flameless graphite tube techniques. [Pg.21]

Chemical vapor deposition (CVD) using TiC was used to prepare Ti/Si02, Ti/MCM-41, and Ti/MCM-48 catalysts. These catalysts were characterized by inductively coupled plasma-atomic emission spectroscopy (ICP-AES), X-ray photoelectron spectroscopy (XPS), Fourier transform infrared (FTIR) spectroscopy, nitrogen adsorption, and were used to catalyze the epoxidation of propylene to propylene oxide (PO) with in situ prepared ethylbenzene hydroperoxide (EBHP). CVD time and CVD temperature affected the catalyst performance significantly. The optimum temperature range was 800-900 °C, and the optimum deposition time was 2.5-3 h. The maximum PO yields obtained in a batch reactor were 87.2, 94.3, and 88.8% for Ti/Si02, Ti/ MCM-41, and Ti/MCM-48, respectively. Ti/MCM-41 had higher titanium... [Pg.373]

Bulk chemical composition of the samples was determined by using an atomic emission spectrometer with an inductively coupled plasma source (Labtam Plasma Lab 8440). [Pg.690]


See other pages where Chemical atomic emission with inductively coupled is mentioned: [Pg.614]    [Pg.418]    [Pg.1571]    [Pg.261]    [Pg.83]    [Pg.76]    [Pg.125]    [Pg.340]    [Pg.245]    [Pg.265]    [Pg.135]    [Pg.17]    [Pg.347]    [Pg.202]    [Pg.427]    [Pg.125]    [Pg.224]    [Pg.259]    [Pg.142]    [Pg.78]    [Pg.217]    [Pg.215]    [Pg.435]    [Pg.222]    [Pg.15]    [Pg.16]    [Pg.89]    [Pg.158]    [Pg.304]    [Pg.1555]    [Pg.1576]    [Pg.1599]   


SEARCH



Atomic coupling

Atomic emission

Chemical atom

Chemical coupling

Chemical coupling with

Chemical induction

Inductive coupling

Inductively coupled

© 2024 chempedia.info