Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Atmospheric pressure chemical ionization , ESI

For abbreviation of analyte names see Sect. Abbreviations . ACN acetonitrile, APCI atmospheric pressure chemical ionization, ESI electrospray ionization, FA formic acid, HFBA heptafluorobutyric acid, IT ion trap, lin range linear range, MeOH methanol, MRM multiple reaction monitoring, n.s. not specified, OAc acetate, QqQ triple quadrupole mass spectrometer, SIM selected ion monitoring, Solv HPLC solvent, SQ single quadrupole mass spectrometer, Ttemperature, TFA trifluoroacetic acid aRatios given as v/v... [Pg.319]

For abbreviation of analyte names see Sect. Abbreviations . APCI atmospheric pressure chemical ionization, ESI electrospray ionization... [Pg.325]

Fig. 5 Statistical evaluation of LC-MS-based methods for tropane alkaloids referred in this chapter. (a) Relative frequency of ionization methods. +APCI positive atmospheric pressure chemical ionization, +ESI positive electrospray ionization, FAB fast atom bombardment, +TSP positive thermospray, (b) Relative frequency of scan modes used. MS full scan MS, MS/MS tandem mass spectrometry (product ion scan), MRM multiple reaction monitoring, SIM selected ion monitoring, (c) Relative frequency of mass analysers used. EBQtQ2 double focusing sector field mass spectrometer, IT ion trap, QqQ triple quadrupole, SQ single quadrupole. Considered publications were found by PubMed data-based search and references cited in these articles... Fig. 5 Statistical evaluation of LC-MS-based methods for tropane alkaloids referred in this chapter. (a) Relative frequency of ionization methods. +APCI positive atmospheric pressure chemical ionization, +ESI positive electrospray ionization, FAB fast atom bombardment, +TSP positive thermospray, (b) Relative frequency of scan modes used. MS full scan MS, MS/MS tandem mass spectrometry (product ion scan), MRM multiple reaction monitoring, SIM selected ion monitoring, (c) Relative frequency of mass analysers used. EBQtQ2 double focusing sector field mass spectrometer, IT ion trap, QqQ triple quadrupole, SQ single quadrupole. Considered publications were found by PubMed data-based search and references cited in these articles...
FIGURE 11.1 A generalized flow scheme that indicates the fundamental elements of LC-MS-based bioanalysis. Abbreviations LLE = liquid-liquid extraction SPE = solid-phase extraction RAM = restricted-access media TEC = turbulent flow liquid chromatography API = atmospheric-pressure ionization APCI = atmospheric-pressure chemical ionization ESI = electrospray ionization SQMS = single-quadrupole mass spectrometry TQMS = triple-quadrupole mass spectrometry TOF = time-of-flight Q-TOF = quadrupole TOF. (Reprinted from Ackermann et al. [4], with permission from John Wiley Sons, Inc.)... [Pg.318]

Ionization methods that may be utihzed in LC-MS include electron ionization (El), chemical ionization (Cl), fast-atom bombardment (FAB), thermospray (TSP), electrospray (ESI) and atmospheric-pressure chemical ionization (APCI). [Pg.52]

Atmospheric-pressure chemical ionization (APCI) is another of the techniques in which the stream of liquid emerging from an HPLC column is dispersed into small droplets, in this case by the combination of heat and a nebulizing gas, as shown in Figure 4.21. As such, APCI shares many common features with ESI and thermospray which have been discussed previously. The differences between the techniques are the methods used for droplet generation and the mechanism of subsequent ion formation. These differences affect the analytical capabilities, in particular the range of polarity of analyte which may be ionized and the liquid flow rates that may be accommodated. [Pg.180]

The most recent progress in MS analysis of chlorophylls has been obtained with the development of atmospheric ionization methods such as atmospheric pressure chemical ionization (APCl) and electrospray ionization (ESI). These techniques have demonstrated much more sensitivity than thermospray ionization, detecting chloro-... [Pg.438]

Reversed-phase Cig chromatography column. Keystone Scientific Betasil, 100 x 2.0-mm i.d., 5-pm particle size, 100 A, Part No. 105-701-2-CPF TSQ 7000 LC/MS/MS system with electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) interface and gradient high-performance liquid chromatography (HPLC) unit, or equivalent Vacuum manifold for use with SPE cartridges (Varian Vac Elut 10 or equivalent)... [Pg.491]

As with GC/MS, LC/MS offers the possibility of unequivocal confirmation of analyte identity and accurate quantiation. Similarly, both quadrupole and ion-trap instruments are commercially available. However, the responses of different analytes are extremely dependent on the type of interface used to remove the mobile phase and to introduce the target analytes into the mass spectrometer. For pesticide residue analyses, the most popular interfaces are electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). Both negative and positive ionization can be used as applicable to produce characteristically abundant ions. [Pg.742]

For confirmatory assay, liquid chromatography-tandem mass spectrometry (LC-MS/MS) is becoming more frequently used in the analysis of OTC owing to its high sensitivity and ability. Electrospray ionization (ESI) [55-57] and atmospheric pressure chemical ionization (APCI) [41] methods combined with tandem mass spectrometry are favored because of their higher sensitivity and better reproducibility. Hamscher et al. [58] developed a method for the determination of persistent TC residues in soil fertilized with manure by HPLC tandem mass spectrometry, MS-MS, and confirmation by MS-MS-MS. Zhu et al. [59] developed an LC-tandem mass spectrometry for the analysis of common tetracyclines in water. The detection limit for oxytetracycline was 0.21 pg/L. Lykkeberg et al. [60] used LC-MS/MS for determination of oxytetracycline and its impurities EOTC, TC, ETC, ADOTC, oc-AOTC, and /i-AOTC. [Pg.111]

Figure 2.1 Mass spectrometric approach. Dl, direct inlet GC, gas chromatography HPLC, high performance liquid chromatography CZE, capillary zone electrophoresis El, electron ionization Cl, chemical ionization ESI, electrospray ionization DESI, desorption electrospray ionization APCI, atmospheric pressure chemical ionization MALDI, matrix assisted laser desorption ionization B, magnetic analyzer E, electrostatic analyzer... Figure 2.1 Mass spectrometric approach. Dl, direct inlet GC, gas chromatography HPLC, high performance liquid chromatography CZE, capillary zone electrophoresis El, electron ionization Cl, chemical ionization ESI, electrospray ionization DESI, desorption electrospray ionization APCI, atmospheric pressure chemical ionization MALDI, matrix assisted laser desorption ionization B, magnetic analyzer E, electrostatic analyzer...
The most important techniques belonging to this class are electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and, more recently, atmospheric pressure photoionization (APPI). At present the latter does not have applications in cultural heritage, so it will be not described here. [Pg.49]

Atmospheric Pressure Chemical Ionization. As its name reveals, APCI[16] is a Cl carried out at atmospheric pressure instead of under vacuum, as occurs for classical Cl. As for ESI, the sample must be in a solution that is continuously flowing into the APCI source (flow rate between 0.2 and 2 ml min ). The solution passes through a pneumatic nebulizer and is desolvated in a heated quartz tube or heating block, thus producing vaporization of solvent and analyte molecules (Figure 2.4). [Pg.50]

For the last several years, mass spectrometry with atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) have determined the trends in the analysis of dyes. Since 1987, various variants of ESI have been used in which droplet formation was assisted by compressed air,[1,2] temperature (e.g. Turbo Ion Spray ) or ultrasound, and they were able to handle flow rates up to 1 2 ml min This made a combination of analytical RPLC and ESI easily and widely used. The reason why it often was (and is) used instead of a traditional UV-Vis detector is the better sensitivity and selectivity of MS in comparison with spectrophotometric detection. Apart from these advantages, MS offers easily interpretable structural information. However, various... [Pg.365]

DGE a AC AMS APCI API AP-MALDI APPI ASAP BIRD c CAD CE CF CF-FAB Cl CID cw CZE Da DAPCI DART DC DE DESI DIOS DTIMS EC ECD El ELDI EM ESI ETD eV f FAB FAIMS FD FI FT FTICR two-dimensional gel electrophoresis atto, 10 18 alternating current accelerator mass spectrometry atmospheric pressure chemical ionization atmospheric pressure ionization atmospheric pressure matrix-assisted laser desorption/ionization atmospheric pressure photoionization atmospheric-pressure solids analysis probe blackbody infrared radiative dissociation centi, 10-2 collision-activated dissociation capillary electrophoresis continuous flow continuous flow fast atom bombardment chemical ionization collision-induced dissociation continuous wave capillary zone electrophoresis dalton desorption atmospheric pressure chemical ionization direct analysis in real time direct current delayed extraction desorption electrospray ionization desorption/ionization on silicon drift tube ion mobility spectrometry electrochromatography electron capture dissociation electron ionization electrospray-assisted laser desorption/ionization electron multiplier electrospray ionization electron transfer dissociation electron volt femto, 1CT15 fast atom bombardment field asymmetric waveform ion mobility spectrometry field desorption field ionization Fourier transform Fourier transform ion cyclotron resonance... [Pg.11]

In addition to the dissolved elements and compounds in the oceanic water column, a wide variety of water column chemicals are found in marine organisms and organic detritus. For example, a milliliter of surface seawater can contain on the order of 10 million viruses, 1 million bacteria, 100,000 phytoplankton, and 10,000 zooplankton [9]. With the advent of soft ionization processes for mass spectrometry systems, scientists have been able to study these marine organisms at molecular level. The use of electrospray ionization (ESI see Section 2.1.15), atmospheric pressure chemical ionization... [Pg.239]

Currently no comprehensive libraries have been developed for methods, such as ESI (see Section 2.1.15) and atmospheric pressure chemical ionization (APCI see Section 2.1.8), used to ionize compounds after LC separation. Generally these types of library are user generated for a specific purpose. [Pg.315]

With the development of sophisticated ionization techniques including electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), HPLC-MS techniques have been successfully applied to the online analysis of ginsenosides in extracts and biological fluids (Fuzzati, 2004). In terms of sensitivity and specificity, an MS detector is better than UV or ELSD. Among the various MS methods, the HPLC-MS-MS (or just LC-MS-MS) technique is to date the most sensitive method for detection and quantification of ginsenosides. [Pg.57]

In atmospheric pressure chemical ionization (APCI) ion-molecule reactions occurring at atmospheric pressure are employed to generate the ions, i.e., it represents a high-pressure version of conventional chemical ionization (Cl, Chap. 7). The Cl plasma is maintained by a corona discharge between a needle and the spray chamber serving as the counter electrode. The ions are transferred into the mass analyzer by use of the same type of vacuum interface as employed in ESI. Therefore, ESI ion sources can easily be switched to APCI instead of an ESI sprayer, a unit comprising a heated pneumatic nebulizer and the spray chamber with the needle electrode are put in front of the orifice, while the atmospheric pressure-to-vacuum interface remains unchanged. [48,138]... [Pg.465]


See other pages where Atmospheric pressure chemical ionization , ESI is mentioned: [Pg.144]    [Pg.54]    [Pg.555]    [Pg.635]    [Pg.144]    [Pg.54]    [Pg.555]    [Pg.635]    [Pg.163]    [Pg.468]    [Pg.525]    [Pg.420]    [Pg.830]    [Pg.1146]    [Pg.1300]    [Pg.26]    [Pg.64]    [Pg.48]    [Pg.54]    [Pg.33]    [Pg.60]    [Pg.142]    [Pg.94]    [Pg.216]    [Pg.22]    [Pg.63]    [Pg.375]    [Pg.192]    [Pg.481]    [Pg.136]    [Pg.150]   


SEARCH



Atmosphere pressure chemical ionization

Atmosphere, ionized

Atmospheric chemical ionization

Atmospheric ionization

Atmospheric pressure chemical

Atmospheric-pressure chemical ionization

Atmospheric-pressure ionization

Chemical ionization

Chemical pressure

ESI

Ionized chemical

© 2024 chempedia.info