Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Emerging from the

For times below about 5 msec a correction must be made to allow for the fact that the surface velocity of the liquid in the nozzle is zero and takes several wavelengths to increase to the jet velocity after emerging from the nozzle. Correction factors have been tabulated [107, 108] see also Ref. 109. [Pg.34]

This is not the case for stimulated anti-Stokes radiation. There are two sources of polarization for anti-Stokes radiation [17]. The first is analogous to that in figure B1.3.3(b) where the action of the blackbody (- 2) is replaced by the action of a previously produced anti-Stokes wave, with frequency 03. This radiation actually experiences an attenuation since the value of Im x o3 ) is positive (leading to a negative gam coefficient). This is known as the stimulated Raman loss (SRL) spectroscopy [76]. Flowever the second source of anti-Stokes polarization relies on the presence of Stokes radiation [F7]. This anti-Stokes radiation will emerge from the sample in a direction given by the wavevector algebra = 2k - kg. Since the Stokes radiation is... [Pg.1205]

After the signal emerges from the lock-m amplifier it still contains a considerable amount of noise. Most of the noise contributions to the signal can be eliminated by passing the signal tlirough a low-pass filter. The filter tune constant is a measure of the cutoff frequency of the filter. If accurate linewidth and g-factor... [Pg.1561]

The sequence space of proteins is extremely dense. The number of possible protein sequences is 20. It is clear that even by the fastest combinatorial procedure only a very small fraction of such sequences could have been synthesized. Of course, not all of these sequences will encode protein stmctures which for functional purjDoses are constrained to have certain characteristics. A natural question that arises is how do viable protein stmctures emerge from the vast sea of sequence space The two physical features of folded stmctures are (l)in general native proteins are compact but not maximally so. (2) The dense interior of proteins is largely made up of hydrophobic residues and the hydrophilic residues are better accommodated on the surface. These characteristics give the folded stmctures a lower free energy in comparison to all other confonnations. [Pg.2646]

The picture of the process of substitution by the nitronium ion emerging from the facts discussed above is that of a two-stage process, the first step in which is rate-determining and which leads to a relatively stable intermediate. In the second step, which is relatively fast, the proton is lost. The transition state leading to the relatively stable intermediate is so constructed that in it the carbon-hydrogen bond which is finally broken is but little changed from its original condition. [Pg.112]

Because a fruit fly for example has about 13 000 genes scientists expected humans to have on the order of 100 000 genes The first surprise to emerge from the... [Pg.1182]

By passing a continuous flow of solvent (admixed with a matrix material) from an LC column to a target area on the end of a probe tip and then bombarding the target with fast atoms or ions, secondary positive or negative ions are ejected from the surface of the liquid. These ions are then extracted into the analyzer of a mass spectrometer for measurement of a mass spectrum. As mixture components emerge from the LC column, their mass spectra are obtained. [Pg.86]

In the earliest interface, a continuous moving belt (loop) was used onto which the liquid emerging from the chromatographic column was placed as a succession of drops. As the belt moved along, the drops were heated at a low temperature to evaporate the solvent and leave behind any mixture components. Finally, the dried components were carried into the ion source, where they were heated strongly to volatilize them, after which they were ionized. [Pg.263]

The electrospray source can be coupled directly to a liquid chromatographic (LC) column so that, as components of a mixture emerge from the column, they are passed through the source to give accurate mass data. As an example, a mixture of the peptides shown in Figure 40.8(a) was separated by LC and accurately mass-analyzed by ES. [Pg.293]

The two electrons emerging from the collision are again speeded until each produces another electron by collisional ionization of another atom of argon. The process continues so the first incident electron becomes two, the two become four, and so on. This cascade increases the number of electrons and ions in the gas to form a plasma within a few milliseconds. [Pg.395]

If a sample is introduced as a solution into the middle of the start of the flame, the combination of high temperatures, energetic electrons, and ions breaks down the sample molecules into constituent atoms and their ions. These elemental ions and atoms emerge from the end of the flame. [Pg.395]

Upon emerging from the quadrupole, the ions are accelerated through about 40 V and focused into the time-of-flight (TOF) analyzer. A pusher electrode is sited alongside this focused ion beam. Application of a pulse of high electric potential (about 1 kV) to the pusher electrode over a period of about 3 ps causes a short section of the ion beam to be detached and accelerated into the TOF analyzer. A positive potential is used to accelerate positively charged ions and vice versa. [Pg.404]

A detector is needed to sense when the separated substances are emerging from the end of the column. A mass spectrometer (MS) makes a very good, sensitive detector and can be coupled to either GC or LC to give the combined techniques of GC/MS or LC/MS, respectively. [Pg.414]

The loop formed by the chain as it emerges from the crystal, turns around, and reenters the crystal may be regarded as amorphous polymer, but is insufficient to account for the total amorphous content of most crystalline polymers. [Pg.211]

The wolume fraction emerges from the Einstein derivation at the natural concentration unit to describe viscosity. This parallels the way volume fraction arises as a natural thermodynamic concentration unit in the Flory-Huggins theory as seen in Sec. 8.3. [Pg.590]

To circumvent this need for calibration as well as to better understand the separation process itself, considerable effort has been directed toward developing the theoretical basis for the separation of molecules in terms of their size. Although partially successful, there are enough complications in the theoretical approach that calibration is still the safest procedure. If a calibration plot such as Fig. 9.14 is available and a detector output indicates a polymer emerging from the column at a particular value of Vj, then the molecular weight of that polymer is readily determined from the calibration, as indicated in Fig. 9.14. [Pg.644]

Since K represents the fraction of Vj at which a particular molecular weight fraction emerges from the column, and since In M cc in r we see that this... [Pg.649]


See other pages where Emerging from the is mentioned: [Pg.177]    [Pg.70]    [Pg.176]    [Pg.757]    [Pg.1716]    [Pg.1770]    [Pg.1830]    [Pg.1887]    [Pg.1971]    [Pg.1986]    [Pg.2420]    [Pg.576]    [Pg.215]    [Pg.49]    [Pg.472]    [Pg.473]    [Pg.85]    [Pg.164]    [Pg.1032]    [Pg.187]    [Pg.150]    [Pg.207]    [Pg.38]    [Pg.56]    [Pg.72]    [Pg.127]    [Pg.160]    [Pg.170]    [Pg.172]    [Pg.277]    [Pg.404]    [Pg.427]    [Pg.642]    [Pg.48]   


SEARCH



Size of the error at emergence from controller saturation

© 2024 chempedia.info