Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analytical techniques mass-spectroscopy

Air Monitoring. The atmosphere in work areas is monitored for worker safety. Volatile amines and related compounds can be detected at low concentrations in the air by a number of methods. Suitable methods include chemical, chromatographic, and spectroscopic techniques. For example, the NIOSH Manual of Analytical Methods has methods based on gas chromatography which are suitable for common aromatic and aHphatic amines as well as ethanolamines (67). Aromatic amines which diazotize readily can also be detected photometrically using a treated paper which changes color (68). Other methods based on infrared spectroscopy (69) and mass spectroscopy (70) have also been reported. [Pg.264]

Materials characterization techniques, ie, atomic and molecular identification and analysis, ate discussed ia articles the tides of which, for the most part, are descriptive of the analytical method. For example, both iaftared (it) and near iaftared analysis (nira) are described ia Infrared and raman SPECTROSCOPY. Nucleai magaetic resoaance (nmr) and electron spia resonance (esr) are discussed ia Magnetic spin resonance. Ultraviolet (uv) and visible (vis), absorption and emission, as well as Raman spectroscopy, circular dichroism (cd), etc are discussed ia Spectroscopy (see also Chemiluminescence Electho-analytical techniques It unoassay Mass specthot thy Microscopy Microwave technology Plasma technology and X-ray technology). [Pg.393]

The field of steroid analysis includes identification of steroids in biological samples, analysis of pharmaceutical formulations, and elucidation of steroid stmctures. Many different analytical methods, such as ultraviolet (uv) spectroscopy, infrared (ir) spectroscopy, nuclear magnetic resonance (nmr) spectroscopy, x-ray crystallography, and mass spectroscopy, are used for steroid analysis. The constant development of these analytical techniques has stimulated the advancement of steroid analysis. [Pg.448]

Mass Spectrometer. The mass spectrometer is the principal analytical tool of direct process control for the estimation of tritium. Gas samples are taken from several process points and analy2ed rapidly and continually to ensure proper operation of the system. Mass spectrometry is particularly useful in the detection of diatomic hydrogen species such as HD, HT, and DT. Mass spectrometric detection of helium-3 formed by radioactive decay of tritium is still another way to detect low levels of tritium (65). Accelerator mass spectroscopy (ams) has also been used for the detection of tritium and carbon-14 at extremely low levels. The principal appHcation of ams as of this writing has been in archeology and the geosciences, but this technique is expected to faciUtate the use of tritium in biomedical research, various clinical appHcations, and in environmental investigations (66). [Pg.15]

Coupling of analytical techniques (detectors) to high-performance liquid chromatographic (HPLC) systems has increased in the last tree decades. Initially, gas chromatography was coupled to mass spectrometry (MS), then to infrai ed (IR) spectroscopy. Following the main interest was to hyphenate analytical techniques to HPLC. [Pg.342]

A number of analytical techniques such as FTIR spectroscopy,65-66 13C NMR,67,68 solid-state 13 C NMR,69 GPC or size exclusion chromatography (SEC),67-72 HPLC,73 mass spectrometric analysis,74 differential scanning calorimetry (DSC),67 75 76 and dynamic mechanical analysis (DMA)77 78 have been utilized to characterize resole syntheses and crosslinking reactions. Packed-column supercritical fluid chromatography with a negative-ion atmospheric pressure chemical ionization mass spectrometric detector has also been used to separate and characterize resoles resins.79 This section provides some examples of how these techniques are used in practical applications. [Pg.407]

Many techniques for the analysis of anthocyanins have been used for almost a century and are still of importance, along with considerable advances in technologies such as mass spectroscopy (MS) and nuclear magnetic resonance (NMR). This section summarizes the analytical procedures for quantitative and qualitative analyses of anthocyanins, including classical and modem techniques. [Pg.480]

A detailed description of sources used in atmospheric pressure ionization by electrospray or chemical ionization has been compiled.2 Atmospheric pressure has been used in a wide array of applications with electron impact, chemical ionization, pressure spray ionization (ionization when the electrode is below the threshold for corona discharge), electrospray ionization, and sonic spray ionization.3 Interferences potentially include overlap of ions of about the same mass-charge ratio, mobile-phase components, formation of adducts such as alkali metal ions, and suppression of ionization by substances more easily ionized than the analyte.4 A number of applications of mass spectroscopy are given in subsequent chapters. However, this section will serve as a brief synopsis, focusing on key techniques. [Pg.59]

Perhaps the most revolutionary development has been the application of on-line mass spectroscopic detection for compositional analysis. Polymer composition can be inferred from column retention time or from viscometric and other indirect detection methods, but mass spectroscopy has reduced much of the ambiguity associated with that process. Quantitation of end groups and of co-polymer composition can now be accomplished directly through mass spectroscopy. Mass spectroscopy is particularly well suited as an on-line GPC technique, since common GPC solvents interfere with other on-line detectors, including UV-VIS absorbance, nuclear magnetic resonance and infrared spectroscopic detectors. By contrast, common GPC solvents are readily adaptable to mass spectroscopic interfaces. No detection technique offers a combination of universality of analyte detection, specificity of information, and ease of use comparable to that of mass spectroscopy. [Pg.375]

Different experimental approaches were applied in the past [6, 45] and in recent years [23, 46] to study the nature of the organic residue. But the results or their interpretation have been contradictory. Even at present, the application of modem analytical techniques and optimized electrochemical instruments have led to different results and all three particles given above, namely HCO, COH and CO, have been recently discussed as possible methanol intermediates [14,15,23,46,47]. We shall present here the results of recent investigations on the electrochemical oxidation of methanol by application of electrochemical thermal desorption mass spectroscopy (ECTDMS) on-line mass spectroscopy, and Fourier Transform IR-reflection-absorption spectroscopy (SNIFTIRS). [Pg.141]

Chemical Analysis. The chemical composition of ancient objects is important for their authentication. The nature as well as the relative amounts of major, minor, and trace elements in any object are of use for determining the authenticity or otherwise of ceramics, glass, or alloys. A wide range of analytical techniques, depending on the nature of the material studied, have been used for this purpose, including X-rays fluorescence analysis, mass spectrometry, atomic absorption spectroscopy, and neutron activation analy-... [Pg.463]

If suitable standards are unavailable (for example, if the FBA has not been encountered previously) the active agent must first be isolated and purified. The pure compound can be characterised by the usual techniques, including elemental analysis and infrared, n.m.r. and mass spectroscopy. Final proof of structure demands synthesis of the FBA indicated by the analytical data. Once again, difficulties may be encountered with compounds of the DAST... [Pg.346]

Modern spectroscopy plays an important role in pharmaceutical analysis. Historically, spectroscopic techniques such as infrared (IR), nuclear magnetic resonance (NMR), and mass spectrometry (MS) were used primarily for characterization of drug substances and structure elucidation of synthetic impurities and degradation products. Because of the limitation in specificity (spectral and chemical interference) and sensitivity, spectroscopy alone has assumed a much less important role than chromatographic techniques in quantitative analytical applications. However, spectroscopy offers the significant advantages of simple sample preparation and expeditious operation. [Pg.265]


See other pages where Analytical techniques mass-spectroscopy is mentioned: [Pg.62]    [Pg.310]    [Pg.37]    [Pg.332]    [Pg.5]    [Pg.33]    [Pg.356]    [Pg.509]    [Pg.298]    [Pg.244]    [Pg.402]    [Pg.606]    [Pg.415]    [Pg.536]    [Pg.139]    [Pg.265]    [Pg.44]    [Pg.241]    [Pg.251]    [Pg.306]    [Pg.179]    [Pg.259]    [Pg.5]    [Pg.57]    [Pg.467]    [Pg.21]    [Pg.24]    [Pg.589]    [Pg.84]    [Pg.4]    [Pg.676]    [Pg.740]    [Pg.5]    [Pg.34]    [Pg.46]    [Pg.20]   
See also in sourсe #XX -- [ Pg.13 , Pg.527 ]




SEARCH



Analytical spectroscopies

Analytical techniques

Mass spectroscopy

Spectroscopy techniques

© 2024 chempedia.info