The properties of gaslike diffusivity and viscosity, zero surface tension, coupled with liquidlike density, combined with the pressure-dependent solvating power of SF have provided the impetus for applying SF technology to analytical separation problems. [Pg.1549]

Slab electrophoresis is now the most widely used separation tool in biochemistry and biology. Monographs, textbooks, and journals in the life sciences contain hundreds of photographs of developed electrophoretic slabs. Capillary electrophoresis. which is ail instrumental version of electrophoresis, was developed in the mid-to-latc 1980s. It has become an important tool for a wide variety of analytical separation problems. In many cases, this new method of performing electrophoretic separations is a satisfactory substitute for slab electrophoresis with several important advantages that are descril>ed later in this chapter. [Pg.868]

The problem with a simple extraction is that the separation only occurs in one direction. In a liquid-liquid extraction, for example, we extract a solute from its initial phase into the extracting phase. Consider, again, the separation of an analyte and a matrix interferent with distribution ratios of 5 and 0.5, respectively. A single liquid-liquid extraction transfers 83% of the analyte and 33% of the interferent to the extracting phase (Figure 12.1). If the concentrations of A and I in the sample were identical, then their concentration ratio in the extracting phase after one extraction is... [Pg.544]

As in tic, another method to vaUdate a chiral separation is to collect the individual peaks and subject them to some type of optical spectroscopy, such as, circular dichroism or optical rotary dispersion. Enantiomers have mirror image spectra (eg, the negative maxima for one enantiomer corresponds to the positive maxima for the other enantiomer). One problem with this approach is that the analytes are diluted in the mobile phase. Thus, the sample must be injected several times. The individual peaks must be collected and subsequently concentrated to obtain adequate concentrations for spectral analysis. [Pg.68]

Analysis of methyl parathion in sediments, soils, foods, and plant and animal tissues poses problems with extraction from the sample matrix, cleanup of samples, and selective detection. Sediments and soils have been analyzed primarily by GC/ECD or GC/FPD. Food, plant, and animal tissues have been analyzed primarily by GC/thermionic detector or GC/FPD, the recommended methods of the Association of Official Analytical Chemists (AOAC). Various extraction and cleanup methods (AOAC 1984 Belisle and Swineford 1988 Capriel et al. 1986 Kadoum 1968) and separation and detection techniques (Alak and Vo-Dinh 1987 Betowski and Jones 1988 Clark et al. 1985 Gillespie and Walters 1986 Koen and Huber 1970 Stan 1989 Stan and Mrowetz 1983 Udaya and Nanda 1981) have been used in an attempt to simplify sample preparation and improve sensitivity, reliability, and selectivity. A detection limit in the low-ppb range and recoveries of 100% were achieved in soil and plant and animal tissue by Kadoum (1968). GC/ECD analysis following extraction, cleanup, and partitioning with a hexane-acetonitrile system was used. [Pg.181]

On-line dialysis also separates the analyte from tissue matrix based upon molecular size, but in this case, the sample extract is passed over a membrane filter through which the analyte (and other low molecular weight compounds) is diffused into a second solvent on the other side of the membrane filter. Usually, the second solvent is then concentrated on to an SPE column to minimize the dilution effect that is caused by the dialysis process. Agasoester used on-line dialysis to separate oxytetracycline from muscle, liver, milk, and egg tissue matrix components. A problem encountered with on-line dialysis is the inability of analyte molecules that are bound to proteins in the sample extract to pass through the membrane filter. Problems with membrane clogging are reduced with on-line dialysis compared with ultrafiltration because no external force is being applied to bring the analyte across the membrane filter. [Pg.310]

A variety of formats and options for different types of applications are possible in CE, such as micellar electrokinetic chromatography (MEKC), isotachophoresis (ITP), and capillary gel electrophoresis (CGE). The main applications for CE concern biochemical applications, but CE can also be useful in pesticide methods. The main problem with CE for residue analysis of small molecules has been the low sensitivity of detection in the narrow capillary used in the separation. With the development of extended detection pathlengths and special optics, absorbance detection can give reasonably low detection limits in clean samples. However, complex samples can be very difficult to analyze using capillary electrophoresis/ultraviolet detection (CE/UV). CE with laser-induced fluorescence detection can provide an extraordinarily low LOQ, but the analytes must be fluorescent with excitation peaks at common laser wavelengths for this approach to work. Derivatization of the analytes with appropriate fluorescent labels may be possible, as is done in biochemical applications, but pesticide analysis has not been such an important application to utilize such an approach. [Pg.781]

To date most of the work which has been done with supercritical fluid extraction has concentrated on the extraction of analytes from solid matrices or liquids supported on an inert solid carrier matrix. The extraction of aqueous matrices presents particular problems [276-278]. The co-extraction of water causes problems with restrictor plugging, column deterioration, and phase separation if a nonpolar solvent is used for sample collection. Also, carbon dioxide isay have limited extraction efficiency for many water soluble compounds. [Pg.411]

The last several years have seen an enormous growth in the number and use of chiral stationary phases in liquid chromatography [742,780-791]. Some problems with the gas chromatographic approach are that the analyte must be volatile to be analyzed and larger-scale preparative separations are frequently difficult. For entropic reasons relatively high temperatures tend to minimize the stability differences between the diastereomeric complexes and racemization of the stationary phase over time may also occur. The upper temperature limit for phases such as Chirasil-Val is about 230 C and is established by the rate of racemization of the chiral centers and not by column bleed. Liquid chromatography should be s ior in the above... [Pg.459]

Detectability may be a significant problem with homologous series of unsaturated compounds, particularly //-alkanes. For these compounds, refractive index detection or evaporative light-scattering, both of which are described elsewhere in the book, may be of use. Indirect photometry is a useful detection scheme for compounds that do not absorb in the UV. Acetone, methylethyl ketone, methyl propyl ketone, methyl isopropyl ketone, methyl isobutyl ketone, and acetophenone are added to an acetonitrile/water mobile phase, generating a negative vacancy peak when the nonchro-mophoric analyte emerges and a positive peak if the ketone is adsorbed and displaced.70 Dodecyl, tetradecyl, cetyl, and stearyl alcohols also have been derivatized with 2-(4-carboxyphenyl)-5,6-dimethylbenzimidazole and the derivatives separated on Zorbax ODS in a mobile phase of methanol and 2-propanol.71... [Pg.161]

The problem of toxic subjects detection in the tested objects can be solved by two options chemical analysis, for revealing separate toxics, or their products, and biotesting with the result of the tested samples toxicity degree indication without identification of the agent. Qualitative and quantitative chrmical/analytical methods allow with the higher accuracy and, in some cases, rapidly detect presence of the separate toxics or their products in the tested objects. It is important for the regular detection of the different pollutions of any agents in the tested objects. [Pg.226]

Many real problems do not satisfy these convexity assumptions. In chemical engineering applications, equality constraints often consist of input-output relations of process units that are often nonlinear. Convexity of the feasible region can only be guaranteed if these constraints are all linear. Also, it is often difficult to tell if an inequality constraint or objective function is convex or not. Hence it is often uncertain if a point satisfying the KTC is a local or global optimum, or even a saddle point. For problems with a few variables we can sometimes find all KTC solutions analytically and pick the one with the best objective function value. Otherwise, most numerical algorithms terminate when the KTC are satisfied to within some tolerance. The user usually specifies two separate tolerances a feasibility tolerance Sjr and an optimality tolerance s0. A point x is feasible to within if... [Pg.281]

As the process model is made more accurate and complicated, you can lose the possibility of obtaining an analytical solution of the optimization problem. For example, if (1) the pressure losses through the pipe fittings and valves are included in the model, (2) the pump investment costs are included as a separate term with a cost exponent (n) that is not equal to 1.0, (3) elevation changes must be taken into account, (4) contained solids are present in the flow, or (5) significant changes in density occur, the optimum diameter will have to be calculated numerically. [Pg.464]

On the basis of the preceding discussion, it should be obvious that ultratrace elemental analysis can be performed without any major problems by atomic spectroscopy. A major disadvantage with elemental analysis is that it does not provide information on element speciation. Speciation has major significance since it can define whether the element can become bioavailable. For example, complexed iron will be metabolized more readily than unbound iron and the measure of total iron in the sample will not discriminate between the available and nonavailable forms. There are many other similar examples and analytical procedures that must be developed which will enable elemental speciation to be performed. Liquid chromatographic procedures (either ion-exchange, ion-pair, liquid-solid, or liquid-liquid chromatography) are the best methods to speciate samples since they can separate solutes on the basis of a number of parameters. Chromatographic separation can be used as part of the sample preparation step and the column effluent can be monitored with atomic spectroscopy. This mode of operation combines the excellent separation characteristics with the element selectivity of atomic spectroscopy. AAS with a flame as the atom reservoir or AES with an inductively coupled plasma have been used successfully to speciate various ultratrace elements. [Pg.251]

Modern-day chemical analysis can involve very complicated material samples—complicated in the sense that there can be many substances present in the sample, creating a myriad of problems with interferences when the lab worker attempts the analysis. These interferences can manifest themselves in a number of ways. The kind of interference that is most famihar is one in which substances other than the analyte generate an instrumental readout similar to the analyte, such that the interference adds to the readout of the analyte, creating an error. However, an interference can also suppress the readout for the analyte (e.g., by reacting with the analyte). An interference present in a chemical to be used as a standard (such as a primary standard) would cause an error, unless its presence and concentration were known (determinant error, or bias). Analytical chemists must deal with these problems, and chemical procedures designed to effect separations or purification are now commonplace. [Pg.299]


See other pages where Analytical separations problems with is mentioned: [Pg.158]    [Pg.158]    [Pg.1075]    [Pg.889]    [Pg.143]    [Pg.113]    [Pg.514]    [Pg.433]    [Pg.25]    [Pg.408]    [Pg.459]    [Pg.879]    [Pg.967]    [Pg.106]    [Pg.290]    [Pg.41]    [Pg.235]    [Pg.244]    [Pg.253]    [Pg.361]    [Pg.435]    [Pg.472]    [Pg.475]    [Pg.547]    [Pg.62]    [Pg.428]    [Pg.450]    [Pg.460]    [Pg.468]    [Pg.339]    [Pg.9]    [Pg.530]   