Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Effluent column

The effluent from the reactor contains both PRODUCT and unreacted FEED which must be separated in a distillation column. Unreacted FEED is recycled to the reactor via a pump if the recycle is liquid or a compressor if the recycle is vapor. [Pg.241]

Removal of bases from mixtures of bases and neutral compounds. The procedure here is essentially the same as in (i) above. The base is retained by the column. Use a solution of 0 05 g. of benzylamine and o-i g. of mannitol in 100 ml. of water. The effluent contains only mannitol. [Pg.57]

Conversion of the salt of a weak base into the free base. Prepare a column of a strong base anion resin (such as Amberlite IRA-40o(OH) ) washed with distilled water as above. Drain off most of the water and then allow 100 ml. of A//2.Na.2C03 solution to pass through the column at 5 ml. per minute. Again wash the column with 200 ml. of distilled water. Dissolve 0-05 g. of aniline hydrochloride in 100 ml. of distilled water and pass the solution down the column. The effluent contains aniline in solution and free from all other ions. [Pg.57]

Typically the effluent from a gas chromato graph is passed through a detector which feeds a sig nal to a recorder whenever a substance different from pure carrier gas leaves the column Thus one... [Pg.572]

FIGURE 13 44 Diagram of a gas chromatograph When connected to a mass spectrometer as in GC/MS the effluent is split into two streams as it leaves the column One stream goes to the detector the other to the mass spectrometer (Adapted with permission from H D Durst and G W Gokel Experimental Organic Chemistry Inti eti McGraw Hill New York 1987)... [Pg.572]

Two common detectors, which also are independent instruments, are Fourier transform infrared spectrophotometers (FT-IR) and mass spectrometers (MS). In GC-FT-IR, effluent from the column flows through an optical cell constructed... [Pg.570]

In GC-MS effluent from the column is introduced directly into the mass spectrometer s ionization chamber in a manner that eliminates the majority of the carrier gas. In the ionization chamber all molecules (remaining carrier gas, solvent, and solutes) are ionized, and the ions are separated by their mass-to-charge ratio. Because each solute undergoes a characteristic fragmentation into smaller ions, its mass spectrum of ion intensity as a function of mass-to-charge ratio provides qualitative information that can be used to identify the solute. [Pg.571]

Electrochemical Detectors Another common group of HPLC detectors are those based on electrochemical measurements such as amperometry, voltammetry, coulometry, and conductivity. Figure 12.29b, for example, shows an amperometric flow cell. Effluent from the column passes over the working electrode, which is held at a potential favorable for oxidizing or reducing the analytes. The potential is held constant relative to a downstream reference electrode, and the current flowing between the working and auxiliary electrodes is measured. Detection limits for amperometric electrochemical detection are 10 pg-1 ng of injected analyte. [Pg.585]

In many applications in mass spectrometry (MS), the sample to be analyzed is present as a solution in a solvent, such as methanol or acetonitrile, or an aqueous one, as with body fluids. The solution may be an effluent from a liquid chromatography (LC) column. In any case, a solution flows into the front end of a mass spectrometer, but before it can provide a mass spectrum, the bulk of the solvent must be removed without losing the sample (solute). If the solvent is not removed, then its vaporization as it enters the ion source would produce a large increase in pressure and stop the spectrometer from working. At the same time that the solvent is removed, the dissolved sample must be retained so that its mass spectrum can be measured. There are several means of effecting this differentiation between carrier solvent and the solute of interest, and thermospray is just one of them. Plasmaspray is a variant of thermospray in which the basic method of solvent removal is the same, but the number of ions obtained is enhanced (see below). [Pg.71]

The LC/TOF instmment was designed specifically for use with the effluent flowing from LC columns, but it can be used also with static solutions. The initial problem with either of these inlets revolves around how to remove the solvent without affecting the substrate (solute) dissolved in it. Without this step, upon ionization, the large excess of ionized solvent molecules would make it difficult if not impossible to observe ions due only to the substrate. Combined inlet/ionization systems are ideal for this purpose. For example, dynamic fast-atom bombardment (FAB), plas-maspray, thermospray, atmospheric-pressure chemical ionization (APCI), and electrospray (ES)... [Pg.163]

The effluent from an LC column or from a static solution supply is passed into an atmospheric-pressure inlet/ion source (Figure 22.1), where ions are produced. The ions are transmitted rapidly... [Pg.166]

In one instrument, ions produced from an atmospheric-pressure ion source can be measured. If these are molecular ions, their relative molecular mass is obtained and often their elemental compositions. Fragment ions can be produced by suitable operation of an APCI inlet to obtain a full mass spectrum for each eluting substrate. The system can be used with the effluent from an LC column or with a solution from a static solution supply. When used with an LC column, any detectors generally used with the LC instrument itself can still be included, as with a UV/visible diode array detector sited in front of the mass spectrometer inlet. [Pg.167]

Schematic diagram of an orthogonal Q/TOF instrument. In this example, an ion beam is produced by electrospray ionization. The solution can be an effluent from a liquid chromatography column or simply a solution of an analyte. The sampling cone and the skimmer help to separate analyte ions from solvent, The RF hexapoles cannot separate ions according to m/z values and are instead used to help confine the ions into a narrow beam. The quadrupole can be made to operate in two modes. In one (wide band-pass mode), all of the ion beam passes through. In the other (narrow band-pass mode), only ions selected according to m/z value are allowed through. In narrow band-pass mode, the gas pressure in the middle hexapole is increased so that ions selected in the quadrupole are caused to fragment following collisions with gas molecules. In both modes, the TOF analyzer is used to produce the final mass spectrum. Schematic diagram of an orthogonal Q/TOF instrument. In this example, an ion beam is produced by electrospray ionization. The solution can be an effluent from a liquid chromatography column or simply a solution of an analyte. The sampling cone and the skimmer help to separate analyte ions from solvent, The RF hexapoles cannot separate ions according to m/z values and are instead used to help confine the ions into a narrow beam. The quadrupole can be made to operate in two modes. In one (wide band-pass mode), all of the ion beam passes through. In the other (narrow band-pass mode), only ions selected according to m/z value are allowed through. In narrow band-pass mode, the gas pressure in the middle hexapole is increased so that ions selected in the quadrupole are caused to fragment following collisions with gas molecules. In both modes, the TOF analyzer is used to produce the final mass spectrum.
The effluent from a GC column is already in the gas phase and needs only to be mixed with argon makeup gas before passage into the flame. Precautions need to be taken to divert temporarily the GC flow when the first solvent peak emerges because it contains far too much material for the plasma to withstand. [Pg.396]

It is possible to dispense with the extraction step if the oxidation section is operated at high propylene concentrations and low steam levels to give a concentrated absorber effluent. In this case, the solvent recovery column operates at total organic reflux to effect a2eotropic dehydration of the concentrated aqueous acryflc acid. This results in a reduction of aqueous waste at the cost of somewhat higher energy usage. [Pg.154]

The reactor effluent, containing 1—2% hydrazine, ammonia, sodium chloride, and water, is preheated and sent to the ammonia recovery system, which consists of two columns. In the first column, ammonia goes overhead under pressure and recycles to the anhydrous ammonia storage tank. In the second column, some water and final traces of ammonia are removed overhead. The bottoms from this column, consisting of water, sodium chloride, and hydrazine, are sent to an evaporating crystallizer where sodium chloride (and the slight excess of sodium hydroxide) is removed from the system as a soHd. Vapors from the crystallizer flow to the hydrate column where water is removed overhead. The bottom stream from this column is close to the hydrazine—water azeotrope composition. Standard materials of constmction may be used for handling chlorine, caustic, and sodium hypochlorite. For all surfaces in contact with hydrazine, however, the preferred material of constmction is 304 L stainless steel. [Pg.282]

Ton-exchange systems vary from simple one-column units, as used in water softening, to numerous arrays of cation and anion exchangers which are dependent upon the appHcation, quaHty of effluent required, and design parameters. An Hlustration of some of these systems, as used in the production of deionized (demineralized) water, is presented in Figure 7. [Pg.381]

Rinse. When transfer of the required volume of regenerating solution to the column has been completed, a small amount of regenerating solution occupies space immediately above the resin bed, between resin particles in the bed, and within the resin particles. It must be displaced with water before the column can be returned to the adsorption step. Rinsing should begin at the same flow rate as used during regeneration and continue at that rate until a volume of water equal to 1—2 bed volumes has been used. After that, the flow rate is increased to the rate normally used during the adsorption step, and continued at that rate until the effluent is of satisfactory quaHty, as deterrnined by pH, conductivity, or resistivity. The water need not be at an elevated temperature unless the process stream is above ambient temperature. [Pg.384]


See other pages where Effluent column is mentioned: [Pg.71]    [Pg.318]    [Pg.87]    [Pg.463]    [Pg.71]    [Pg.318]    [Pg.87]    [Pg.463]    [Pg.21]    [Pg.57]    [Pg.58]    [Pg.55]    [Pg.84]    [Pg.101]    [Pg.107]    [Pg.250]    [Pg.283]    [Pg.651]    [Pg.48]    [Pg.68]    [Pg.123]    [Pg.182]    [Pg.241]    [Pg.337]    [Pg.201]    [Pg.372]    [Pg.372]    [Pg.378]    [Pg.380]    [Pg.382]    [Pg.383]    [Pg.384]    [Pg.386]    [Pg.388]    [Pg.274]    [Pg.251]   
See also in sourсe #XX -- [ Pg.210 ]




SEARCH



Column chromatography effluent collection

Columns effluent composition

Effluent

© 2024 chempedia.info