Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Timing stability

The shortest IRF obtained with TCSPC and MCP PMTs is eurrently 25 to 30 ps. With some 10 recorded photons the variance of the first moment of the IRF is of the order of 10 fs. A statistieal aeeuraey on this level is indeed eonfirmed by distance measurements based on TCSPC [340, 341]. A ehange in the first moment is directly related to a ehange in a fluorescence lifetime. One eould therefore presume that TCSPC reveals lifetime effeets down to the time seale of a few 10 fs. [Pg.296]

However, if the full cathode area of 11 mm diameter is illuminated, the response remains stable up to more than a 3 MHz reeorded count rate, with a shift in the first moment of less than 3 ps. The response eurves are shown in Fig. 7.35, right. [Pg.298]

PMT Operating Voltage Voltage Count Rate IRF Shift Amphtude- [Pg.298]

Type (Gain Control Divider MHz width of Ml Phase-Cross- [Pg.298]

These results show that MCP PMTs can be used for eount rates up to the maximum useful count rate of currently available TCSPC systems. It should be noted, however, that at a count rate of 3.3 MHz and an operating voltage of 3 kV the output current is considerably higher than the specified maximum of 100 nA. This is certainly not a problem in applications where high count rates appear only temporarily, e.g. in scanning microscopy. The lifetime of the MCP is not known at a continuous count rate of more than 3 MHz. [Pg.298]


One consequence of perfonning the stabilization procedure is that the initial conditions that correspond to the current g (R) are changed each time stabilization is perfomied. However this does not matter as long the mitial g (R) value corresponds to the limit 0 as then all one needs is for g (R) to be small (i.e., die actual value is not important). [Pg.986]

Bronze disease necessitates immediate action to halt the process and remove the cause. For a long time, stabilization was sought by removal of the cuprous chloride by immersing the object in a solution of sodium sesquicarbonate. This process was, however, extremely time-consuming, frequentiy unsuccesshil, and often the cause of unpleasant discolorations of the patina. Objects affected by bronze disease are mostiy treated by immersion in, or surface appHcation of, 1 H-henzotriazole [95-14-7] C H N, a corrosion inhibitor for copper. A localized treatment is the excavation of cuprous chloride from the affected area until bare metal is obtained, followed by appHcation of moist, freshly precipitated silver oxide which serves to stabilize the chloride by formation of silver chloride. Subsequent storage in very dry conditions is generally recommended to prevent recurrence. [Pg.425]

The specification development process is a data-driven activity that requires a validated analytical method. The levels of data needed include assay precision, replicate process results (process precision), and real-time stability profiles. A statistical analysis of these data is critical in setting a realistic specification. Most often, aggregation and fragmentation degradation mechanisms are common to protein and peptide therapeutics. Therefore, the SE-HPLC method provides a critical quality parameter that would need to be controlled by a specification limit. [Pg.535]

NO sensors can be characterized in terms of sensitivity, detection limit, selectivity, response time, stability, linear range, lifetime, reproducibility, and biocompatibility. Sensor stability is important especially when measuring low NO concentrations. For example, when measuring low NO concentrations it must be the case that the noise... [Pg.33]

The introduction of powerful electron-withdrawing substituents (NO2, CN, a polynitrogen heterocycle) at the a-C atom of AN stabilize anions of AN, thus facilitating their generation. At the same time, stabilization of anions of AN leads to a decrease in their reactivity and such anions act as milder nucleophilic agents. It will be seen from the following that this leads to an increase in the contribution of C-alkylation. [Pg.441]

This analysis confirms that the effect of cyclic constraints is not purely steric but also has an electronic component. Another aspect of this dichotomy is shown in Fig. 11 which illustrates the decrease in the energy gap between the frontier in-plane rc-MOs. The decrease in the C1-C6 distance destabilizes the occupied MO where the interaction between the end orbitals is antibonding and, at the same time, stabilizes the empty MO where the 7i -orbitals overlap constructively. As a result, the efficiency of the photochemical Bergman cyclization should increase and, indeed, the most efficient photo-Bergman cyclizations reported in the literature involve cyclic enediynes.43 Again, the analogy with interrupted [2 + 2] photocycloaddition is instructive. [Pg.15]

Foreign clinical results are acceptable except in areas where there are immunological and ethnic differences between Japanese and foreigners. The ethnic factors are divided into two components intrinsic factors such as racial factors and physiological differences and extrinsic factors, which include cultural and environmental issues. In these cases, the MHLW may require that some bridging comparative clinical trials be performed with dose ranging protocols. This will enable absorption, distribution, metabolism, and excretion studies to be carried out on Japanese individuals and provide better dosage and indication for the Japanese people. The MHLW also requires that application be accompanied by one year of real-time stability data and that sterility test results be included. [Pg.216]

For drug substances, a retest date is generally determined. The period up to the retest date is a period during which the material is known to adhere to its specification, for example, for assay or degradants. The retest date may be assigned on the basis of real-time stability data obtained at the recommended storage conditions or on the basis of accelerated stability data obtained under more stressful conditions. [Pg.11]

Reinforcing and reducing procedures are used at the same time stabilization (tonifying action) and movement (drying and drainage action) coexist in one formula. However, the main action of the formula is stabilization. [Pg.136]

It is well known, even from old literature data (ref. 1) that the presence of metal promotors like molybdenum and chromium in Raney-nickel catalysts increases their activity in hydrogenation reactions. Recently Court et al (ref. 2) reported that Mo, Or and Fe-promoted Raney-nickel catalysts are more active for glucose hydrogenation than unpromoted catalysts. However the effects of metal promotors on the catalytic activity after repeated recycling of the catalyst have not been studied so far. Indeed, catalysts used in industrial operation are recycled many times, stability is then an essential criterion for their selection. From a more fundamental standpoint, the various causes of Raney-nickel deactivation have not been established. This work was intended to address two essential questions pertinent to the stability of Raney-nickel in glucose hydrogenation namely what are the respective activity losses experienced by unpromoted or by molybdenum, chromium and iron-promoted catalysts after recycling and what are the causes for their deactivation ... [Pg.231]

Foam volume stability Change in foam volume with time Stability is often expressed as half-life of the loam. The half-life is defined as the time for half the liquid to drain or half the foam to collapse. [Pg.297]

The first was a modification of ASTM D793-49 (1965) which describes a procedure for determining the short-time stability at elevated temperatures of plastics containing chlorine. Utilizing the apparatus described therein, 5 grams of polymer in the form of powder, as isolated from the grafting reaction or as obtained commercially, was heated to 180 °C, and the evolved hydrogen chloride was carried by preheated... [Pg.323]

EPMEs based on carbon paste impregnated with a-, />- and y-cyclo-dextrins are proposed for the assay of L-proline [31]. Response characteristics showed that the proposed electrodes could be reliably used in the assay of L-proline, with the best enantioselectivity and time-stability exhibited by a-cyclodextrin based EPME. The EPMEs based on the proposed unsubstituted cyclodextrins showed lower detection limits (10 10 magnitude order) than the one previously studied, based on /J-cyclodextrin derivative [30]. The widest linear concentration range is recorded for the y-cyclodextrin based EPME (10 8-10-3mol/L). The recovery tests performed for the assay of L-proline in the presence of d-proline (recoveries higher than 99.65%) proved that the proposed... [Pg.61]

Compared to genosensors based on GEC, the novelty of this approach is in part attributed to the simplicity of its design, combining the hybridization and the immobilization of DNA in one analytical step. The optimum time for the one-step immobilization/hybridization procedure was found to be 60 min [66]. The proposed DNA biosensor design has proven to be successful in using a simple bulk modification step, hence, overcoming the complicated pre-treatment steps associated with other DNA biosensor designs. Additionally, the use of a one-step immobilization and hybridization procedure reduces the experimental time. Stability studies conducted demonstrate the capability of the same electrode to be used for a 12-week period [66]. [Pg.454]

The main problem with periodic TDFRS is, that the different frequencies are measured at different times. This requires a long-time stability, especially of the heterodyne reference, lasting about as long as the entire experiment. Time domain experiments, on the other hand, are frequency multiplexed, and stability of the heterodyne background is only required for one homodyne/heterodyne separation cycle as described in the experimental section, which is only of the order of seconds, not hours. No stability of the signal amplitude is required for the averaging of C lel(t) over arbitrary times. [Pg.42]

Paclitaxel and docetaxel have been shown to act as spindle poisons, causing cell division cycle arrest, based on a unique mechanism of action.7-10 These drugs bind to the P-subunit of the tubulin heterodimer, the key constituent protein of cellular microtubules (spindles). The binding of these drugs accelerates the tubulin polymerization, but at the same time stabilizes the resultant microtubules, thereby inhibiting their depolymerization. The inhibition of microtubule depolymerization between the prophase and anaphase of mitosis results in the arrest of the cell division cycle, which eventually leads to the apoptosis of cancer cells. [Pg.71]

Finally, the robustness of the calibration is a critical parameter that must be established before any noninvasive measurement technology will be useful. Important issues include (1) the ability to collect reliable spectra for each measurement (2) a protocol required to establish a working calibration model (3) time stability of a calibration model and (4) sensitivity of the calibration model to external factors, such as ambient temperature and vibrations. These issues go far beyond demonstrating the feasibility of a noninvasive spectroscopic sensor but pertain to its eventual practical implementation. [Pg.351]


See other pages where Timing stability is mentioned: [Pg.496]    [Pg.62]    [Pg.990]    [Pg.72]    [Pg.202]    [Pg.154]    [Pg.284]    [Pg.231]    [Pg.155]    [Pg.125]    [Pg.78]    [Pg.259]    [Pg.133]    [Pg.58]    [Pg.344]    [Pg.157]    [Pg.117]    [Pg.392]    [Pg.358]    [Pg.388]    [Pg.477]    [Pg.62]    [Pg.347]    [Pg.1640]    [Pg.152]    [Pg.101]    [Pg.2]    [Pg.327]    [Pg.30]    [Pg.253]    [Pg.419]    [Pg.368]    [Pg.259]   


SEARCH



Detectors timing stability

Glass long-time stability

Induction times oxidation stability

Mechanical stability time

Stability in time

Stability time step restrictions

Stability, long time

Stabilization time

Stabilization time

Stabilized processing time

The intra-individual stability of elementary times

Time-dependent wellbore stability

Time-stability

© 2024 chempedia.info