Calibration working

Understanding the distribution allows us to calculate the expected values of random variables that are normally and independently distributed. In least squares multiple regression, or in calibration work in general, there is a basic assumption that the error in the response variable is random and normally distributed, with a variance that follows a ) distribution. [Pg.202]

HR-ICP-MS EEEMENT-2 (Pinnigan MAT, Germany) equipped with a standard introduction system (quartz water-cooled spray chamber, concentric nebulizer, torch with 1.5 mm i.d. injector and nickel cones) was used for measurements. The following operating conditions were used RP power 1150 W, coolant gas flow rate 16 1 min k auxiliary gas flow rate 0.85 1 min nebulizer gas flow rate 1.2 1 min k Sample uptake rate was 0.8-1 ml min k Measurements were performed with low and middle resolutions. Rh was used as an internal standard. Por calibration working standard solutions were prepared by diluting the multielemental stock solutions CPMS (SPEX, USA) with water to concentration range from 5 ng to 5 p.g I k... [Pg.287]

Do calibrate working standards against calibration standards that have at least an order of accuracy greater than the working standards. [Pg.425]

Details can be found in chapter 4 of the book by Hehre et al. as cited in the references. As a further aside, it is worth noting that despite of the title of this book which is "Ab Initio Molecular Orbital Theory", the authors admit on the very first page that most of the book is devoted to calibrated work ... [Pg.108]

We have said that every time the calibration analyzes a new unknown sample, this amounts to an additional validation test of the calibration. It can be a major mistake to believe that, just because a calibration worked well when it was being developed, it will continue to produce reliable results from that point on. When we discussed the requirements for a training set, we said that collection of samples in the training set must, as a group, be representative in all ways of the unknowns that will be analyzed by the calibration. If this condition is not met, then the calibration is invalid and cannot be expected to produce reliable results. Any change in the process, the instrument, or the measurement procedure which introduces changes into the data measured on an unknown will violate this condition and invalidate the method If this occurs, the concentration values that the calibration predicts for unknown samples are completely unreliable We must therefore have a plan and procedures in place that will insure that we are alerted if such a condition should arise. [Pg.24]

In those days, Statistics was more highly regarded than it is now, and the analytical chemists then knew the fundamental requirements of doing calibration work. There are several we need not go into all of them now, but the one that is pertinent to our current discussion is the one that states that, while the y-variable may contain error, the X-variable must be known without error. Now, in the real world this is never true, since all quantities are the result of some measurement, which will therefore have error... [Pg.121]

In addition, very few observations are pristine and basic measurements such as angular deviation of a needle on a display, linear expansion of a fluid, voltages on an electronic device, only represent analogs of the observation to be made. These observations are themselves dependent on a model of the measurement process attached to the particular device. For instance, we may assume that the deviation of a needle on a display connected to a resistance is proportional to the number of charged particles received by the resistance. The model of the measurement is usually well constrained and the analyst should be in control of the deterministic part through calibration, working curves, assessment of non-linearity, etc. If the physics of the measurement is correctly understood, the residual deviations from the experimental calibration may be considered as random deviates. Their assessment is an integral part of the measurement protocol and the moments of these random deviations should be known to the analyst and incorporated in the model. [Pg.248]

Note Besides from elongated deteetion intervals, mass aeeuraey of FT-ICR-MS also benefits by a faetor of 3-10 from internal mass ealibration compared to external calibration (Chap. 3.3.5). External calibration works the better, the closer the cyclotron radius and the number of calibrant ions fit the conditions of the intended analytical measurements. [200]... [Pg.171]

Assessing linearity is an important aspect in calibration work since lack-of-fit will usually lead to biased results. When a simple linear regression model is chosen, the more general test of goodness-of-fit becomes a test of linearity. [Pg.236]

NB This pilot study included only six concentration levels with a five-component PLS model there is a virtual certainty of over fitting the model. Even a two-segment cross validation is no absolute guarantee [2], but does supply the only possible validation basis with any credibility. However, the results in Figure 9.23 indicate and substantiate satisfactory possibilities for continuing to the type of extended calibration work needed in a full-fledged industrial calibration setting. [Pg.299]

Control of the activities (control of nonconforming testing and/or calibration work, improvement, corrective action, preventive action, internal audits, management reviews)... [Pg.22]

The laboratory shall have a policy and procedure for the resolution of complaints received from clients or other parties. Records shall be maintained of all complaints and of the investigations and corrective actions taken by the laboratory. The laboratory shall have a policy and procedmes that shall be implemented when any aspect of its testing and/or calibration work, or the results of this work, do not coirform to "... [Pg.31]

Only trained personnel should be employed for performing the calibration work. The above requirements are applicable for subcontractors performing calibration work on behalf of your company. Outside calibration laboratories should be inspected. [Pg.119]

Do personnel performing calibration functions have appropriate experience or training applicable to the type of calibration work undertaken ... [Pg.130]

Subsection 4.9 Control of Nonconforming Testing or Calibration Work... [Pg.272]

The values of the relative densities confirm what is visually apparent cokes (a) and (d) are more dense than are cokes (b) and (c). It should be noted that these calculations are relative since the intensity has not been externally calibrated. Work is in progress to calibrate the cyclohexane signal intensity in the zeolite HSY surrounding the coke beans. [Pg.515]

The calibration of atomic spectrometers can be handled much easier than that of conventional IC detectors using the large dynamic range of ICP techniques. Those simple off-line calibrations had been used for ICP-AES and ICP-MS in on-line preconcentration applications. With its ability to decide between isotopes the ICP-MS is well suited for isotope dilution analysis (IDMS), a calibration tool which increases the accuracy, the results and saves time due to reduced calibration work. The use of IDMS in combination with on-line coupling methods allows a significant speedup of the usually to IDMS applied time consuming separation processes. [Pg.1011]

Experimental differences between calibration work and routine use can introduce model error. The sapphire viewing port was used as a convenient, built-in reference sample. The calibration models were built before the reactor was sterilized. Unfortunately, the window material changed slightly during sterilization. The resulting subtle differences in the reference spectra collected before and after sterilization hurt the model s predictive ability. Reference samples are useful only if they are stable. [Pg.149]

For calibration work in the UV range, spectra should have a maximum absorbance less than 1 for Beer s law to be obeyed and to obtain good linear response. Clearly, since this condition does not hold for the simulated calibration spectra shown in Figure 8.28, a simple dilution of the calibration samples should be performed before measuring their UV spectra. This is applicable to any sample type, as the dilution only affects the analysis method and not the final result. [Pg.330]

Future improvement needs include increased efforts for calibration work, work to extend volatility limits using the direct insertion probe or the field desorption technique (7), and the development of fast and sharp separation methods for specific compound classes. [Pg.28]

To assess the certainty with which the extent of difference in amino acid sequence can be inferred from immunological distance, we have estimated prediction intervals for five kinds of monomeric proteins. These estimates are made possible by the extensive calibration work done in our laboratory on proteins of known amino acid sequence. This chapter then uses prediction intervals to test the robustness of hypotheses about phene-tic relationships among monomeric proteins of mammals, frogs, and birds. The probabilities of arriving at various conclusions by chance range from 1 in 20 to 1 in 10 billion. [Pg.141]

Although °Th has found widespread use as a CFP, applications are limited by its 75 ka half-life to sediments deposited during the past —300 ka. Paleoceanographic research would clearly benefit from a CFP that can be applied further back in time. Calibration work is underway to determine the suitability of extraterrestrial He, contained in interplanetary dust particles (IDPs), as a CFP that may be applied to much older sediments. [Pg.3118]

The characterization of star-branched polymers has been performed using triple detection because it was not obvious, in the beginning of this study, that universal calibration could be applied to star-branched polymers. In fact, the GPC software used handles experimental data as a double dual detection, GPC-viscometry and GPC-LALLS. Experimentally, it has been found that excellent agreement between results from these two sets of data can be obtained. GPC-viscometry uses a universal calibration curve and GPC-LALLS is free of any molecular weight calibration curve. Therefore, the universal calibration works well with very long chain branched polymers, even with a very particular... [Pg.177]

Sondermann and Kovar described a study using NIRS for the identification of ecstasy street samples. Ecstasy tablets may contain either A-methyl-3,4-methylendioxyamphetamine (MDMA) or A-ethyl-3,4-methylendioxyamphetamine (MDE) as well as other amphetamine derivatives. In addition, various excipients were present, and non-standardized production procedures contributed to inhomogeneous tablets. The authors researchers included a broad range of excipients in their calibration work and succeeded in constructing three PLS models for identification. [Pg.3636]


See other pages where Calibration working is mentioned: [Pg.306]    [Pg.392]    [Pg.62]    [Pg.425]    [Pg.430]    [Pg.432]    [Pg.226]    [Pg.245]    [Pg.142]    [Pg.31]    [Pg.87]    [Pg.119]    [Pg.269]    [Pg.208]    [Pg.153]    [Pg.151]    [Pg.306]    [Pg.175]    [Pg.3638]    [Pg.169]    [Pg.62]    [Pg.425]    [Pg.430]    [Pg.432]   
See also in sourсe #XX -- [ Pg.210 , Pg.219 , Pg.223 , Pg.225 , Pg.251 , Pg.292 ]




SEARCH



Energy calibration work function measurement

Working calibration standards

Working calibration standards using

Working with calibration curves