Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Supply levels

Another example is the Keepit Dam in the river Namoi (Australia). The alterations produced by this dam on water temperature were studied by Preece and Jones [13]. This dam has a storage capacity of 423 hm3, a maximum depth of 40 m and water is released through a fixed-level intake structure with the inlet located at 24 m bellow full supply level. The mean discharge of the river Namoi downstream of the dam is circa 7 m3/s. Just downstream from the dam, a 5°C decrease of the annual maximum temperature was observed, and a delay of the same of 22 days. As the distance increased, the natural thermal regime was recovered at 100 km downstream from the dam, the differences in water temperature with respect to the situation former to the construction of the dam were less than 1°C. [Pg.79]

RDA s are specified by sex/age categories, but they can be expressed as a single value for the population by taking Into consideration the distribution of sex/age groups within the United States. On this basis, the "population" RDA for 1981 would be 14.2 mg per capita per day. This Is still higher than the food supply level of 12.2 mg per capita per day for 1981. Nutrient levels In the food supply are averages for the entire population. Therefore, certain segments of the population may choose from the food supply a diet that provides the RDA, while others may choose... [Pg.28]

Cheynier, V., Souquet, J.M., Samson, A. Moutounet, M. (1991). Hyperoxidation influence of various oxygen supply levels on oxidation kinetics of phenolic compounds and wine quality. Vitis, 30, 107-115. [Pg.121]

Sufficient quantities of phosphorus (P), potassium (K) and magnesium (Mg) are usually added to the soil along with organic material (compost or manure). The deliberate addition of these minerals is only advisable if there is some evidence of deficiency or if supply levels are in categories A, B or C (low, moderate or sufficient). [Pg.71]

Ultralev. [Mfg s Chem. Supply] Leveling agent, dyeing assistant, retarding agent fix textiles. [Pg.387]

A Limited Announcement can be made for a new substance supplied at <1 tonne a, or to a restricted number of specified users for commercial development at above this amount for 1 year only. L.ess information is required for Limited Announcement for supply at <10 kg a, and even less for <1 kg a. Comparatively few new substances reach the 1 tonne a supply level, so most are authorised under the Limited Announcement scheme, although sometimes the full EC Base Set data are available to enable definitive and complete hazard classification and labelling and avoid having to label the substance as Caution Substance not yet fully tested . [Pg.553]

Iron availability is low in rice and maize-based phytate-rich Third World diets, and blood losses due to hook-worm infections are frequent in these countries. Iron deficiency is the most widespread micronutrient deficiency besides vitamin A and iodide. The prevalence of iron deficiency may be as high as 60% in Third World pre-school children, and almost half of these children (26%) show iron-deficiency anemia (Romero-Abal et al. 1995). However, about half of the even higher prevalence for anemia of up to 70% in African women and children (Quar-shie and Amoaful 1998) seems attributable to inflammation and parasitic infections (Asobayire et al. 2001) and other micronutrient deficiencies, rather than to iron deficiency (Allen et al. 2000). Hypochromic microcytic iron-deficiency anemia reduces physical work capacity, and both show a close correlation (Dallman 1982). As the brain is luxuriously perfused with blood, impairment of intellectual performance in anemia is a very variable symptom. Anemia at an age of 12-18 months seems to compromise the infant s intellectual development. To what extent such deficits in intelligence can be compensated during later development at adequate iron supply levels has been discussed, somewhat controversially, by Walter (1993) and Pollitt (2001). [Pg.819]

The method of detecting iodine supply levels and the evaluation of the effect of the lack or oversupply (Boyages, 1993) of iodine on the condition of the thyroid gland (its size, function and the impact on the autoimmunity process) and the resulting evaluation of the overall condition of health of an entire population (from the occurrence of endemic cretinism due to significant lack of iodine to mild occurrence of brain dysfunction due to lack of iodine during intrauterine development) problems in the development of the somatic. [Pg.835]

The results of a 10-city drinking water survey reported the presence of di- -butyl phthalate in 6 of 10 city water supplies. Levels ranged from 0.1 to 0.2 pg/L for five cities the level was 5.0 pg/L for one city (Keith etal. 1976). [Pg.120]

Remote actuated valves must be chosen to match process requirements. Design decisions include materials of construction, valve seat material, valve t q)e, actuator type and controls characteristics. The design must match utility supply levels (air pressure, hydraulic pressure, flow capacity) and tolerances with actuator design to provide the correct torque/thrust to the valve. The torque/thrust must be above breakaway requirements and must be below stress limits of the drive train. With some valves, the ratio of these values may limit the available operating safety factor. [Pg.158]

As mentioned earlier, these bottlenecks are only partly applicable when we consider supply-level integration naturally process temperatures will have an impact on the supply line temperatures and return flow temperatures will as well be influenced by the process design however, this is most true for water-based distribution systems and less for steam systems. High-energy peaks and varying loads will pose no challenge for supply... [Pg.307]

Errors in modeling may arise if due eare is not taken in developing fault/event tree models or identifying appropriate failure meehanisms. For an example, let us consider an area that has two toxie gas deteetors, either of whieh ean close an emergency isolation valve. In the fault tree, both deteetors would have to fail for leak detection failure to oeeur and the events would be ANDed together. The fault tree should be described down to the power supply level. This would ensure that the Boolean solution to the fault tree would capture the case... [Pg.223]

Gas dispersion modeling capabilities that compute protective action distances based on either levels of concern stored in the system or a user-supplied level of concern... [Pg.400]

You set up storage levels in the material flow. From the supplier to the storage levels (e.g. modules and variant parts), economical production has priority. Up to this point you can e.g. use price-efficient extended workbenches with corresponding core areas of competence despite longer throughput times. As of the supply level, the fast assembly for the customer order has top priority. With this method, variant vendors also save on the high capital tie-up in the product inventory for all kinds of variants. [Pg.239]

Inventory forecast Ordering costs Order calculation Operating data collection Supply levels... [Pg.290]

The daily requirement is given in Table 6.3. Deficiency symptoms are rarely observed with a normal diet and, since the riboflavin pool in the body is very stable, even in a deficient diet it is not depleted by more than 30-50%. The riboflavin content of urine is an indicator of riboflavin supply levels. Values above 80pg riboflavin/g creatinine are normal 27-79 pg/g are low and less than 27 pg/g strongly suggests a vitamin-deficient diet. Glutathione reductase activity assay can provide similar information. [Pg.413]

Assuming 70% level of the UGS in the present case study at the moment of disruption, maximum discharge level can be maintained for 15 days. Duration for lower supply levels are shown in Table 3. The model simulations in a time-dependent manner can be performed for each day, however due to memory limitations, 4 time steps were used, assuming minimum flow available. Time step 5 was also used reflecting empty storage situation. [Pg.2072]

Figure 5 shows CDF at different time steps and the effect of storage supply can be quantified. Computations were performed for different supply levels at the main pipeline connection (Node 2), having maximum capacity of 19.2 mcm per day (Table 2). The following hypothetical supply capacity of Node 2 was analysed ... [Pg.2074]

The biasing resistor serves two purposes. First, it sets a proper DC bias voltage at the input node of the OTA. The bias voltages are usually set to the midway voltage between Vdd and Vss. which is equivalent to the circuit ground in case a dual power-supply level is used. Second, it determines the low-frequency cut-off of the amplifier because it forms a high-pass filter with the input capacitor C. Therefore, the cut-off frequency of the filter is and to achieve the cut-off frequency... [Pg.258]

From (5), we can understand that the DC output common level Vq is purely determined by the geometric parameter of Mp2 and In general, it is preferable to set Vo to (I dd + Vss)/2, which is GND in this design, for maximum output range. Assuming symmetrical dual power-supply level, (Vdd = — Vss) the desired geometric ratio of two source transistors, k can be set as below ... [Pg.260]

Since the diode turn-on voltage Vt (0.3-0.7 V) is one order less than the power-supply level Vdd (>10 V), the two diodes should have very short turn-on time per cycle. Thereby, it is reasonable to ignore the higher order harmonics of Vc2 (voltage on the resonant capacitor C2), and the amplitude of Vc2 is approximately Vdd + T Assuming Vc2 with zero-phase, the relative phase information of Vmd C2. and /l2 is illustrated in Fig. 26. [Pg.293]

The Subcommittee on Operations of the USCWC took what it considered a more realistic and detailed approach to the problem. The subcommittee felt that any regrouping of the theaters for purposes of reserve supply levels should be based on the type of operations that were planned and upon the activities and locations of specific numbers of troops within the theaters.Accordingly, the USCWC recommended that the planners divide the troop strength of each theater into one or more classes of supply instead of placing the entire theater in one class. The committee reasoned that in certain theaters, such as SWPA, there were troops far to the rear— as in Australia—where enemy gas attack was improbable, whereas other troops in forward areas such as New Guinea were daily exposed to the possibility of Japanese use of gas, The USCWC suggested reserve levels of 100 percent for troops in forward areas within a theater, 50 percent for men in second class areas further to the rear, and only 5 percent for troops in the most remote areas. These levels applied to all types of protective equipment and supplies which would be used only if gas warfare started.This policy the War Department directed the ASF to implement. ... [Pg.81]

The tentative stock control manual stipulated that the new system was to go into effect by 1 June 1943. It provided that each post, camp, and station as of that date would have an established supply level based on the actual needs of troop units. This level in most cases was first established as a 90-day level, a figure which fluctuated from time to time. All stocks above the established level were to be declared excess and returned to the depots. Stock levels were also established for the depots. Much co-operation was necessary among the commanding officers of the headquarters of the technical services, the headquarters of the service commands, the depots, and the post supply officers in order to fix accurate stock levels, but this objective was gradually accomplished. ... [Pg.402]

Monitoring of board s power supply levels via AD converters which are part of microcontroller unit (MCU)... [Pg.40]


See other pages where Supply levels is mentioned: [Pg.12]    [Pg.12]    [Pg.19]    [Pg.204]    [Pg.29]    [Pg.55]    [Pg.535]    [Pg.146]    [Pg.367]    [Pg.300]    [Pg.234]    [Pg.156]    [Pg.360]    [Pg.103]    [Pg.115]    [Pg.139]    [Pg.259]    [Pg.269]    [Pg.288]    [Pg.40]    [Pg.228]    [Pg.138]    [Pg.215]   


SEARCH



© 2024 chempedia.info