Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Spectrophotometry Spectroscopy

J. C. Travis and G. W. Kramer, NIST-traceable-reference-material optical filters program for chemical spectrophotometry, Spectroscopy, 14(2), 1999. [Pg.172]

After incorporating the atomic absorption spectrophotometry (spectroscopy) to the hospital laboratories has been observed that the medical research has improved in these laboratories. In this chapter the highlighted technique has been presented through a few research examples with different metals. [Pg.20]

Relaxation kinetics may be monitored in transient studies tlirough a variety of metliods, usually involving some fonn of spectroscopy. Transient teclmiques and spectrophotometry are combined in time resolved spectroscopy to provide botli tire stmctural infonnation from spectral measurements and tire dynamical infonnation from kinetic measurements that are generally needed to characterize tire mechanisms of relaxation processes. The presence and nature of kinetic intennediates, metastable chemical or physical states not present at equilibrium, may be directly examined in tliis way. [Pg.2946]

The evaluation of instrumentation for molecular UV/Vis spectroscopy is reviewed in the following pair of papers. Altermose, 1. R. Evolution of Instrumentation for UV-Visible Spectrophotometry Parti, /. Chem. Educ. 1986, 63, A216-A223. [Pg.458]

Analytical deterrnination of nickel in solution is usually made by atomic absorption spectrophotometry and, often, by x-ray fluorescence spectroscopy. [Pg.13]

Only slightly less accurate ( 0.3—0.5%) and more versatile in scale are other titration techniques. Plutonium maybe oxidized in aqueous solution to PuO " 2 using AgO, and then reduced to Pu" " by a known excess of Fe", which is back-titrated with Ce" ". Pu" " may be titrated complexometricaHy with EDTA and a colorimetric indicator such as Arsenazo(I), even in the presence of a large excess of UO " 2- Solution spectrophotometry (Figs. 4 and 5) can be utilized if the plutonium oxidation state is known or controlled. The spectrophotometric method is very sensitive if a colored complex such as Arsenazo(III) is used. Analytically usehil absorption maxima and molar absorption coefficients ( s) are given in Table 10. Laser photoacoustic spectroscopy has been developed for both elemental analysis and speciation (oxidation state) at concentrations of lO " — 10 M (118). Chemical extraction can also be used to enhance this technique. [Pg.200]

It is becoming more and more desirable for the analytical chemist to move away from the laboratory and iato the field via ia-field instmments and remote, poiat of use, measurements. As a result, process analytical chemistry has undergone an offensive thmst ia regard to problem solviag capabihty (77—79). In situ analysis enables the study of key process parameters for the purpose of definition and subsequent optimization. On-line analysis capabihty has already been extended to gc, Ic, ms, and ftir techniques as well as to icp-emission spectroscopy, flow iajection analysis, and near iafrared spectrophotometry (80). [Pg.397]

Numerous methods have been pubUshed for the determination of trace amounts of tellurium (33—42). Instmmental analytical methods (qv) used to determine trace amounts of tellurium include atomic absorption spectrometry, flame, graphite furnace, and hydride generation inductively coupled argon plasma optical emission spectrometry inductively coupled plasma mass spectrometry neutron activation analysis and spectrophotometry (see Mass spectrometry Spectroscopy, optical). Other instmmental methods include polarography, potentiometry, emission spectroscopy, x-ray diffraction, and x-ray fluorescence. [Pg.388]

The detection and determination of traces of cobalt is of concern in such diverse areas as soflds, plants, fertilizers (qv), stainless and other steels for nuclear energy equipment (see Steel), high purity fissile materials (U, Th), refractory metals (Ta, Nb, Mo, and W), and semiconductors (qv). Useful techniques are spectrophotometry, polarography, emission spectrography, flame photometry, x-ray fluorescence, activation analysis, tracers, and mass spectrography, chromatography, and ion exchange (19) (see Analytical TffiTHODS Spectroscopy, optical Trace and residue analysis). [Pg.371]

Infrared Spectrophotometry. The isotope effect on the vibrational spectmm of D2O makes infrared spectrophotometry the method of choice for deuterium analysis. It is as rapid as mass spectrometry, does not suffer from memory effects, and requites less expensive laboratory equipment. Measurement at either the O—H fundamental vibration at 2.94 p.m (O—H) or 3.82 p.m (O—D) can be used. This method is equally appticable to low concentrations of D2O in H2O, or the reverse (86,87). Absorption in the near infrared can also be used (88,89) and this procedure is particularly useful (see Infrared and raman spectroscopy Spectroscopy). The D/H ratio in the nonexchangeable positions in organic compounds can be determined by a combination of exchange and spectrophotometric methods (90). [Pg.9]

Several books and symposium proceedings on luminescence standards and measurements have been published in the last several years, including "Advances in Standards and Methodology in Spectrophotometry" (i), "Measurement of Fhotolumlnescence" (2), "Standards in Fluorescence Spectrometry" (J), and "Modern Fluorescence Spectroscopy" (Volumes 1-4) (4). These books, the references within them, and the classic in the field, "Photoluminescence of Solutions" by C.A. Parker (5), provide the researcher with extensive information about luminescence standards and measurements. [Pg.99]

Burgess, C. Mlelenz. K. D., Eds. Advances in Standards and Methodology in Spectrophotometry Analytical Spectroscopy Library Elsevier Science Amsterdam, 1987 Vol. 2. [Pg.123]

Abstract Protoberberine alkaloids and related compounds represent an important class of molecules and have attracted recent attention for their various pharmacological activities. This chapter deals with the physicochemical properties of several isoquinoline alkaloids (berberine, palmatine and coralyne) and many of their derivatives under various environmental conditions. The interaction of these compounds with polymorphic DNA structures (B-form, Z-form, H -form, protonated form, triple helical form and quadruplex form) and polymorphic RNA structures (A-form, protonated form, triple helical form and quadruplex form) reported by several research groups, employing various analytical techniques such as spectrophotometry, spectrofluorimetry, circular dichro-ism, NMR spectroscopy, viscometry as well as molecular modelling and thermodynamic analysis to elucidate their mode and mechanism of action for structure-activity relationships, are also presented. [Pg.156]

Table 5.5 shows the main characteristics of UV spectrophotometry as applied to polymer/additive analysis. Growing interest in automatic sample processing looks upon spectrophotometry as a convenient detection technique due to the relatively low cost of the equipment and easy and cheap maintenance. The main advantage of UV/VIS spectroscopy is its extreme sensitivity, which permits typical absorption detection limits in solution of 10-5 M (conventional transmission) to 10 7 M (photoacoustic). The use of low concentrations of substrates gives relatively ideal solutions [20]. As UV/VIS spectra of analytes in solution show little fine structure, the technique is of relatively low diagnostic value on the other hand, it is one of the most widely used for quantitative analysis. Absorption of UV/VIS light is quantitatively highly accurate. The simple linear relationship between... [Pg.306]

Use of UV spectroscopy in hyphenation to separation techniques is described in Chapter 7. tobirtski and Marczenko [16] have described recent advances in UV/VIS spectrophotometry. [Pg.307]

Applications Applications of UV/VIS spectrophotometry can be found in the areas of extraction monitoring and control, migration and blooming, polymer impregnation, in-polymer analysis, polymer melts, polymer-bound additives, purity determinations, colour body analysis and microscopy. Most samples measured with UV/VIS spectroscopy are in solution. However, in comparison to IR spectroscopy additive analysis in the UV/VIS range plays only a minor role as only a limited class of compounds exhibits specific absorption bands in the UV range with an intensity proportional to the additive concentration. Characteristic UV absorption bands of various common polymer additives are given in Scheirs [24],... [Pg.307]

As the majority of stabilisers has the structure of aromatics, which are UV-active and show a distinct UV spectrum, UV spectrophotometry is a very efficient analytical method for qualitative and quantitative analysis of stabilisers and similar substances in polymers. For UV absorbers, UV detection (before and after chromatographic separation) is an appropriate analytical tool. Haslam et al. [30] have used UV spectroscopy for the quantitative determination of UVAs (methyl salicylate, phenyl salicylate, DHB, stilbene and resorcinol monobenzoate) and plasticisers (DBP) in PMMA and methyl methacrylate-ethyl acrylate copolymers. From the intensity ratio... [Pg.307]

The scope of UV analysis of dissolved polymer/additive matrices is thus quite restricted and mainly limited to special cases in which the additive package is known, e.g. the determination of Irganox 1098 in GFR-PA4.6 after dissolution in H2SO4/HNO3. Fibre-optic dissolution analysis by means of a UV diode array spectrometer is well known. In comparison to IR spectroscopy, UV spectrophotometry is better equipped to provide quantitative data. [Pg.696]

Horwitz claims that irrespective of the complexity found within various analytical methods the limits of analytical variability can be expressed or summarized by plotting the calculated mean coefficient of variation (CV), expressed as powers of two [ordinate], against the analyte level measured, expressed as powers of 10 [abscissa]. In an analysis of 150 independent Association of Official Analytical Chemists (AOAC) interlaboratory collaborative studies covering numerous methods, such as chromatography, atomic absorption, molecular absorption spectroscopy, spectrophotometry, and bioassay, it appears that the relationship describing the CV of an analytical method and the absolute analyte concentration is independent of the analyte type or the method used for detection. [Pg.483]

Refiny product (copper), 7 671 Reflectance, of ODRs, 14 858-859 Reflectance spectrophotometry, 9 232 Reflectance techniques, in infrared spectroscopy, 14 230-232 Reflectancy, 7 305... [Pg.794]


See other pages where Spectrophotometry Spectroscopy is mentioned: [Pg.2949]    [Pg.509]    [Pg.524]    [Pg.58]    [Pg.416]    [Pg.418]    [Pg.265]    [Pg.904]    [Pg.94]    [Pg.181]    [Pg.204]    [Pg.44]    [Pg.46]    [Pg.301]    [Pg.302]    [Pg.303]    [Pg.305]    [Pg.306]    [Pg.309]    [Pg.696]    [Pg.734]    [Pg.331]    [Pg.260]    [Pg.474]    [Pg.128]   


SEARCH



Absorption spectroscopy spectrometry, spectrophotometry

Spectrophotometry ultraviolet-visible spectroscopy

Ultraviolet spectrophotometry/spectroscopy

Ultraviolet spectrophotometry/spectroscopy groups

© 2024 chempedia.info