Sample spectrophotometry

Selectivity The selectivity of molecular fluorescence and phosphorescence is superior to that of absorption spectrophotometry for two reasons first, not every compound that absorbs radiation is fluorescent or phosphorescent, and, second, selectivity between an analyte and an interferant is possible if there is a difference in either their excitation or emission spectra. In molecular luminescence the total emission intensity is a linear sum of that from each fluorescent or phosphorescent species. The analysis of a sample containing n components, therefore, can be accomplished by measuring the total emission intensity at n wavelengths. [Pg.433]

In spectrophotometry the absorbance per unit length of path through the sample e is defined as... [Pg.661]

Determination of gold concentrations to ca 1 ppm in solution via atomic absorption spectrophotometry (62) has become an increasingly popular technique because it is available in most modem analytical laboratories and because it obviates extensive sample preparation. A more sensitive method for gold analysis is neutron activation, which permits accurate determination to levels < 1 ppb (63). The sensitivity arises from the high neutron-capture cross section (9.9 x 10 = 99 barns) of the only natural isotope, Au. The resulting isotope, Au, decays by P and y emission with a half-life of 2.7 d. [Pg.381]

Mineral and Chemical Composition. X-ray diffraction is used to determine the mineral composition of an Mg(OH)2 sample. Induced coupled plasma (icp) spectrophotometry is used to measure the atomic concentrations present in a sample. X-ray fluorescence analysis is another comparative instmmental method of determining chemical composition. [Pg.349]

Spectrophotometric deterrnination at 550 nm is relatively insensitive and is useful for the deterrnination of vitamin B 2 in high potency products such as premixes. Thin-layer chromatography and open-column chromatography have been appHed to both the direct assay of cobalamins and to the fractionation and removal of interfering substances from sample extracts prior to microbiological or radioassay. Atomic absorption spectrophotometry of cobalt has been proposed for the deterrnination of vitamin B 2 in dry feeds. Chemical methods based on the estimation of cyanide or the presence of 5,6-dimethylben2irnida2ole in the vitamin B 2 molecule have not been widely used. [Pg.115]

BeryUium aUoys ate usuaUy analyzed by optical emission or atomic absorption spectrophotometry. Low voltage spark emission spectrometry is used for the analysis of most copper-beryUium aUoys. Spectral interferences, other inter-element effects, metaUurgical effects, and sample inhomogeneity can degrade accuracy and precision and must be considered when constmcting a method (17). [Pg.68]

Mean values from duplicate analyses of each of three samples by atomic absorption spectrophotometry. [Pg.98]

Cahbration with standard reflectance and transmittance samples should be routinely used for optimum results in spectrophotometry and colorimetry. Cahbration of the wavelength (32) and photometric (33) scales is also advisable. The cahbration of a white reflectance standard in terms of the perfect reflecting diffuse, T, has been discussed (34), as have diagnostic tiles for tristimulus colorimetry (35). A collaborative reference program is available on instmment performance (36). [Pg.417]

In this work hybrid method is suggested to determine anionic surfactants in waters. It is based on preconcentration of anionic surfactants as their ion associates with cationic dyes on the membrane filter and measurement of colour intensity by solid-phase spectrophotometry method. Effect of different basic dyes, nature and hydrophobicity of anionic surfactants, size of membrane filter pores, filtration rate on sensitivity of their determination was studied. Various cationic dyes, such as Methylene Blue, Crystal Violet, Malachite Green, Rhodamine 6G, Safranin T, Acridine Yellow were used as counter ions. The difference in reflection between the blank and the sample was significant when Crystal Violet or Rhodamine 6G or Acridine Yellow were used. [Pg.267]

Sulphur dioxide Directional dust gauges Sampling equipment for determination of gaseous sulphur Thorin spectrophotometry... [Pg.357]

Lab method using glass-fibre/Tenax tube sampling and high performance liquid chromatography Field method using acid hydrolysis, diazotization, coupling and spectrophotometry... [Pg.360]

First, let us consider batch mixing processes, as exemplified by ordinaiy laboratory practice in solution kinetics. A portion of one solution (say, of the substrate) is added by pipet to a second solution (containing the reagent) in a flask, the flask is shaken to achieve homogeneity, and then samples are withdrawn at known times for analysis, or the solution is subjected to continuous observation as a function of time, for example, by spectrophotometry. For reactions on a time scale (measured by the half-life) of hours or even several minutes, the time consumed in these operations is a negligible portion of the reaction time, but as the half-life of the reaction decreases, it becomes necessary to consider these preliminary steps. Let us distinguish three stages ... [Pg.176]

Optical methods of analysis are dependent either upon (i) measurement of the amount of radiant energy of a particular wavelength absorbed by the sample, or (ii) the emission of radiant energy and measurement of the amount of energy of a particular wavelength emitted. Absorption methods are usually classified according to the wavelength involved as (a) visible spectrophotometry (colorimetry), (b) ultraviolet spectrophotometry, and (e) infrared spectrophotometry. [Pg.7]

Standard addition. A known amount of the constituent being determined is added to the sample, which is then analysed for the total amount of constituent present. The difference between the analytical results for samples with and without the added constituent gives the recovery of the amount of added constituent. If the recovery is satisfactory our confidence in the accuracy of the procedure is enhanced. The method is usually applied to physico-chemical procedures such as polarography and spectrophotometry. [Pg.132]

Further techniques which may be applied directly to the solvent extract are flame spectrophotometry and atomic absorption spectrophotometry (AAS).13 The direct use of the solvent extract in AAS may be advantageous since the presence of the organic solvent generally enhances the sensitivity of the method. However, the two main reasons for including a chemical separation in the preparation of a sample for AAS are ... [Pg.174]

Theory. Conventional anion and cation exchange resins appear to be of limited use for concentrating trace metals from saline solutions such as sea water. The introduction of chelating resins, particularly those based on iminodiacetic acid, makes it possible to concentrate trace metals from brine solutions and separate them from the major components of the solution. Thus the elements cadmium, copper, cobalt, nickel and zinc are selectively retained by the resin Chelex-100 and can be recovered subsequently for determination by atomic absorption spectrophotometry.45 To enhance the sensitivity of the AAS procedure the eluate is evaporated to dryness and the residue dissolved in 90 per cent aqueous acetone. The use of the chelating resin offers the advantage over concentration by solvent extraction that, in principle, there is no limit to the volume of sample which can be used. [Pg.212]

Methods are described for determining the extent to which original natural color is preserved in processing and subsequent storage of foods. Color differences may be evaluated indirectly in terms of some physical characteristic of the sample or extracted fraction thereof that is largely responsible for the color characteristics. For evaluation more directly in terms of what the observer actually sees, color differences are measured by reflectance spectrophotometry and photoelectric colorimetry and expressed as differences in psychophysical indexes such as luminous reflectance and chromaticity. The reflectance spectro-photometric method provides time-constant records in research investigation on foods, while photoelectric colorimeters and reflectometers may prove useful in industrial color applications. Psychophysical notation may be converted by standard methods to the colorimetrically more descriptive terms of Munsell hue, value, and chroma. Here color charts are useful for a direct evaluation of results. [Pg.3]

Spectrophotometry. The instrument generally used for this basic type of measurement is the spectrophotometer. The data obtained, usually pictured in the form of a spectrophotometric curve, indicate the ability of the sample to transmit or reflect light of the various wave lengths. Various instruments are available which can be used to determine more or less complete spectrophotometric curves. [Pg.4]

Some preliminary laboratory work is in order, if the information is not otherwise known. First, we ask what the time scale of the reaction is surely our approach will be different if the reaction reaches completion in 10 ms, 10 s, 10 min, or 10 h. Then, one must consider what quantitative analytical techniques can be used to monitor it progress. Sometimes individual samples, either withdrawn aliquots or individual ampoules, are taken. More often a nondestructive analysis is performed, the progress of the reaction being monitored continuously or intermittently by a technique such as ultraviolet-visible spectrophotometry or nuclear magnetic resonance. The fact that both reactants and products might contribute to the instrument reading will not prove to be a problem, as explained in the next chapter. [Pg.10]

Ross, R. T. and Gonzalez, J. G. "Direct Determination of Trace Quantities of Manganese In Blood and Serum Samples Using Selective Volatilization and Graphite Tube Reservoir Atomic Absorption Spectrophotometry". Bull. Environ. [Pg.269]

TLC spectrophotometry is used to determine zirconium in Mg-Al alloy. For this purpose, the alloy sample (2 g) is dissolved in HNO3 (20 ml, 6 M), and zirconium is extracted in 6 ml of 0.02-M diantipyrilmethane (DAM) solution in chloroform. The extract was concentrated to 0.4 ml and an aliquot (10 p,l) was chromatographed on silica gel LS plate using 4-M HCl -f dimethylformamide (1 2) as the mobile phase. After development, the portion of the sorbent layer containing the zirconium-DAM complex was removed, and the metal was extracted with 6-M HCl. The zirconium present in this solution was determined in the form of a xylenol orange complex (Amax, 540 nm) by spectrophotometry [22]. [Pg.360]

Separation and detection methods The common methods used to separate the Cr(III)/(VI) species are solvent extraction, chromatography and coprecipitation. In case of Cr(VI) from welding fumes trapped on a filter, a suitable leaching of the Cr(VI) from the sample matrix is needed, without reducing the Cr(VI) species. The most used detection methods for chromium are graphite furnace AAS, chemiluminescence, electrochemical methods, ICP-MS, thermal ionization isotope dilution mass spectrometry and spectrophotometry (Vercoutere and Cornelis 1995)- The separation of the two species is the most delicate part of the procedure. [Pg.79]

Samples are hydrolyzed with hydrochloric acid and stannous chloride solution at elevated temperature, and the evolved carbon disulfide is drawn with an air steam through two gas washing tubes in series containing lead acetate and sodium hydroxide solutions and an absorption tube containing an ethanolic solution of cupric acetate and diethanolamine. Lead acetate and sodium hydroxide remove hydrogen sulfide and other impurities. In the absorption tube, the carbon disulfide forms two cupric complexes of Af,Af-bis(2-hydroxyethyl)dithiocarbamic acid with molecular ratios Cu CS2 of 1 1 and 1 2. These complexes are measured simultaneously by spectrophotometry at 453 nm. [Pg.1092]


See other pages where Sample spectrophotometry is mentioned: [Pg.358]    [Pg.358]    [Pg.2949]    [Pg.48]    [Pg.224]    [Pg.685]    [Pg.707]    [Pg.812]    [Pg.635]    [Pg.396]    [Pg.166]    [Pg.195]    [Pg.213]    [Pg.416]    [Pg.749]    [Pg.6]    [Pg.9]    [Pg.276]    [Pg.293]    [Pg.79]    [Pg.509]    [Pg.264]    [Pg.359]    [Pg.58]    [Pg.88]    [Pg.651]    [Pg.464]   
See also in sourсe #XX -- [ Pg.12 ]