Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sample preparation concentration

Perform prevalidation linearity study By analyzing sufficient data points to determine the linear range, sample preparation concentrations and related compound detection and quantitation limits can be estimated. Consideration must be given to the capability of the HPLC instrumentation that will eventually run the method. [Pg.150]

Sample preparation Concentrate urine by ultrafiltration-dialysis then chromatograph on Phenyl-Sepharose CL4B. [Pg.548]

The main objective of analysis is to ensure the water supplied to the public meets the relevant standards and does not exceed the recommended concentration of hazardous chemicals. The analyses performed by the water laboratory for compliance purposes should be performed in an accredited laboratory and comply with the recognized standard for technical competence of testing laboratories. A complete analytical procedure should include information on sample handling (collection, transport, and storage), sample preparation (concentrate and separate), analysis (methods to identify and quantify components), analytical quality control (criteria), and reporting of analytical results. [Pg.5009]

Absolute diethyl ether. The chief impurities in commercial ether (sp. gr. 0- 720) are water, ethyl alcohol, and, in samples which have been exposed to the air and light for some time, ethyl peroxide. The presence of peroxides may be detected either by the liberation of iodine (brown colouration or blue colouration with starch solution) when a small sample is shaken with an equal volume of 2 per cent, potassium iodide solution and a few drops of dilute hydrochloric acid, or by carrying out the perchromio acid test of inorganic analysis with potassium dichromate solution acidified with dilute sulphuric acid. The peroxides may be removed by shaking with a concentrated solution of a ferrous salt, say, 6-10 g. of ferrous salt (s 10-20 ml. of the prepared concentrated solution) to 1 litre of ether. The concentrated solution of ferrous salt is prepared either from 60 g. of crystallised ferrous sulphate, 6 ml. of concentrated sulphuric acid and 110 ml. of water or from 100 g. of crystallised ferrous chloride, 42 ml. of concentrated hydiochloric acid and 85 ml. of water. Peroxides may also be removed by shaking with an aqueous solution of sodium sulphite (for the removal with stannous chloride, see Section VI,12). [Pg.163]

The following experiments introduce students to the importance of sample preparation and methods for extracting analytes from their matrix. Each experiment includes a brief description of the sample and analyte, as well as the method of analysis used to measure the analyte s concentration. [Pg.226]

A major advantage of this hydride approach lies in the separation of the remaining elements of the analyte solution from the element to be determined. Because the volatile hydrides are swept out of the analyte solution, the latter can be simply diverted to waste and not sent through the plasma flame Itself. Consequently potential interference from. sample-preparation constituents and by-products is reduced to very low levels. For example, a major interference for arsenic analysis arises from ions ArCE having m/z 75,77, which have the same integral m/z value as that of As+ ions themselves. Thus, any chlorides in the analyte solution (for example, from sea water) could produce serious interference in the accurate analysis of arsenic. The option of diverting the used analyte solution away from the plasma flame facilitates accurate, sensitive analysis of isotope concentrations. Inlet systems for generation of volatile hydrides can operate continuously or batchwise. [Pg.99]

Determination of gold concentrations to ca 1 ppm in solution via atomic absorption spectrophotometry (62) has become an increasingly popular technique because it is available in most modem analytical laboratories and because it obviates extensive sample preparation. A more sensitive method for gold analysis is neutron activation, which permits accurate determination to levels < 1 ppb (63). The sensitivity arises from the high neutron-capture cross section (9.9 x 10 = 99 barns) of the only natural isotope, Au. The resulting isotope, Au, decays by P and y emission with a half-life of 2.7 d. [Pg.381]

Preparation of soil—sediment of water samples for herbicide analysis generally has consisted of solvent extraction of the sample, followed by cleanup of the extract through Uquid—Uquid or column chromatography, and finally, concentration through evaporation (285). This complex but necessary series of procedures is time-consuming and is responsible for the high cost of herbicide analyses. The advent of soUd-phase extraction techniques in which the sample is simultaneously cleaned up and concentrated has condensed these steps and thus gready simplified sample preparation (286). [Pg.49]

The very low Hg concentration levels in ice core of remote glaciers require an ultra-sensitive analytical technique as well as a contamination-free sample preparation methodology. The potential of two analytical techniques for Hg determination - cold vapour inductively coupled plasma mass spectrometry (CV ICP-SFMS) and atomic fluorescence spectrometry (AFS) with gold amalgamation was studied. [Pg.171]

Investigated is the influence of the purity degree and concentration of sulfuric acid used for samples dissolution, on the analysis precision. Chosen are optimum conditions of sample preparation for the analysis excluding loss of Ce(IV) due to its interaction with organic impurities-reducers present in sulfuric acid. The photometric technique for Ce(IV) 0.002 - 0.1 % determination in alkaline and rare-earth borates is worked out. The technique based on o-tolidine oxidation by Ce(IV). The relative standard deviation is 0.02-0.1. [Pg.198]

Determination of Na " and Na" ions in raw cosmetic materials was conducted with the developed method of flame photometry. A necessity of development of method of samples preparation arose up in the work process, as this spicily-aromatic raw material contained pectin in amount 0.1-0.5% and that prevented preparation of samples by standard method of extracts dilution and required incineration of analyzed sample, time of analysis was increased in 60 times. It was established that CaCl, solution with the concentration 0,4 % caused destmctions of the carbopol gel. It was established that the addition of 0,1% CaCl, and 0,1% NaCl salts solutions into the system intensified the effect of negative action of these salts onto the gel stmcture and the gel destmcted completely. [Pg.375]

Large quantities of solvents are employed for sample preparation, in particular, and these are then concentrated down to a few milliliters. So particularly high quality materials that are as free as possible from residual water and especially free from nonvolatile or not readily volatile impurities ought to be employed here such impurities are enriched on concentration and can lead to gross contamination. The same considerations also apply to preparative chromatography. Special solvents of particular purity are now available. [Pg.121]

The nitration of 6-methoxyquinoxaline in concentrated sulfuric acid at 0°C gives 6-methoxy-5-nitroquinoxaline. The position of the nitro group is confirmed by reduction of the product to 5-amino-6-methoxy-quinoxaline identical with a sample prepared from 2,3,4-triamino-anisole and glyoxal ... [Pg.211]

There is greater similarity in the behavior of stretched melts and solid samples prepared by, e.g. pressure molding, probably, for the reason of parallelism in structure formation and destruction caused by deformation in melts and the amorphous regions of solid matrices. It is also possible to use identical equations for longitudinal viscosity and strength which present them as functions of the filler concentration [34]. [Pg.5]

Minerals generally present difficult problems in chemical analysis, and these problems grow more serious when the elements being determined are as difficult to separate as are those named above. The time and effort that x-ray emission spectrography can save are therefore great, but there are obstacles to be surmounted. Among these are (1) Absorption and enhancement effects are often serious. (2) The element of interest may be present at low concentration in a matrix that is unknown and variable. (3) Satisfactory standards are not always easy to obtain. (4) Simple equipment sometimes does not resolve important analytical lines- completely. (5) Sample preparation and particle size often influence the intensities of analytical lines Class II deviations (7.8) can be particularly serious with minerals. [Pg.199]

The quantification of kinins in human tissues or body fluids has been limited due to the inherent difficulties in accurately measuring the concentration of ephemeral peptides. Today HPLC-based and RIA/capture-ELA measurements are established to determine kinins in human plasma, liquor or mine. Serine protease inhibitors need to be added to prevent rapid degradation of the kinins in vitro during sample preparation. Kinins and their degradation products have been studied in various biological milieus such as plasma/ serum, urine, joint fluids, kidney, lung and skeletal muscle [2]. Under normal conditions, the concentration of kinins in these compartments is extremely low for... [Pg.673]

Experiments at present are concentrated on sd-metals and Pt-group metals. The sp-metals, on which theories of the double layer have been based, are somewhat disregarded. In some cases the most recent results date back more than 10 years. It would be welcome if double-layer studies could be repeated for some sp-metals, with samples prepared using actual surface procedures. For instance, in the case of Pb, the existing data manifest a discrepancy between the crystalline system and the crystal face sequence of other cases (e.g., Sn and Zn) the determination of EgaQ is still doubtful. For most of sp-metals, there are no recent data on the electron work function. [Pg.192]

Sample preparation will involve extraction techniques, concentration procedures and methods for removing solid contaminants that may damage the sample valve, column or some other part of the... [Pg.195]


See other pages where Sample preparation concentration is mentioned: [Pg.129]    [Pg.618]    [Pg.419]    [Pg.293]    [Pg.129]    [Pg.129]    [Pg.618]    [Pg.419]    [Pg.293]    [Pg.129]    [Pg.1645]    [Pg.350]    [Pg.198]    [Pg.323]    [Pg.303]    [Pg.315]    [Pg.148]    [Pg.69]    [Pg.1694]    [Pg.90]    [Pg.124]    [Pg.235]    [Pg.250]    [Pg.378]    [Pg.436]    [Pg.69]    [Pg.136]    [Pg.267]    [Pg.286]    [Pg.286]    [Pg.221]    [Pg.536]    [Pg.15]    [Pg.194]    [Pg.375]    [Pg.39]    [Pg.180]   
See also in sourсe #XX -- [ Pg.389 ]




SEARCH



Sample concentration

Sample preparation solute concentration

Sampling concentration

© 2024 chempedia.info