An overview of the most important quaternary ammonium salts tested for possible applicability in zinc-bromine batteries is presented in Table 2. A rough classification has been applied according to the substance classes of the substituents attached to the nitrogen. [Pg.181]

In contrast to aspirin itself, the U.S.P. monograph for aspirin tablets has undergone considerable changes. For some reason, U.S.P. does not use the ferric salt test for free salicylic acid, as does the British Pharmacopeia of 1973. Apparently, certain excipients such as citric and tartaric acid interfere with this reaction.77 Already in 1913, a double titration method was developed78 which was made an official method in 1926.79 This method was used as the assay method when the aspirin tablets monograph was introduced into U.S.P. XII in 1942. [Pg.22]

Methods of preparing soluble salts Methods of preparing insoluble salts More about salts Testing for different salts... [Pg.128]

Fungus-resistance tests are used to determine the reaction of adhesives to several species of fungi under high humidity and a warm environment in the presence of inorganic salts. Testing for fungus resistance is more appropriate for exposed adhesives as in printed-wiring assemblies than for hermetically sealed devices or modules. One test method specified as Method 4.5.14 in IPC-SM-817 references Method 2.6.1 of IPC-TM-650, Test Methods Manual... [Pg.359]

Trichloroethanoic acid, CCI3COOH. A crystalline solid which rapidly absorbs water vapour m.p. 58°C, b.p. 196-5" C. Manufactured by the action of chlorine on ethanoic acid at 160°C in the presence of red phosphorus, sulphur or iodine. It is decomposed into chloroform and carbon dioxide by boiling water. It is a much stronger acid than either the mono- or the dichloro-acids and has been used to extract alkaloids and ascorbic acid from plant and animal tissues. It is a precipitant for proteins and may be used to test for the presence of albumin in urine. The sodium salt is used as a selective weedkiller. [Pg.94]

The thiocyanate ion SCN forms an intensely red-coloured complex (most simply represented as [Fe(SCN)(H20)5] ) which is a test for iron(III). However, unlike cobalt(III), iron(lll) does not form stable hexammines in aqueous solution, although salts containing the ion [FefNHj) ] can be obtained by dissolving anhydrous iron(III) salts in liquid ammonia. [Pg.395]

The reactions of aqueous solutions of nickel(II) salts with hydroxide ions, with excess ammonia, with sulphide ion and with dimethyl-glyoxime (see above) all provide useful tests for nickel(II) ions. [Pg.408]

Copper(II) ions in aqueous solution are readily obtained from any copper-containing material. The reactions with (a) alkali (p. 430), (b) concentrated ammonia (p 413) and (c) hydrogen sulphide (p. 413) provide satisfactory tests for aqueous copper(II) ions. A further test is to add a hexacyanoferrate(II) (usually as the potassium salt) when a chocolate-brown precipitate of copper(II) hexacyanoferrate(II) is obtained ... [Pg.416]

Sodium benzoate,—Burns with great difficulty, and after prolonged heating leaves a white infusible residue of NajCOj. Scrape this residue into a test-tube, and test for carbonate in the usual way. Typical of alkali salts of carboxylic acids. [Pg.319]

Now grind up the mixture of solution and glass in the mortar to ensure extraction of the sodium salts, and then filter. Divide the filtrate into three portions, reserving two portions for testing for halogens and sulphur. [Pg.322]

Di-n-butyl ether. Technical n-butyl ether does not usually contain appreciable quantities of peroxides, unless it has been stored for a prolonged period. It should, however, be tested for peroxides, and, if the test is positive, the ether should be shaken with an acidified solution of a ferrous salt or with a solution of sodium sulphite (see under Diethyl ether). The ether is dried with anhydrous calcium chloride, and distilled through a fractionating column the portion, b.p. 140-141°, is collected. If a fraction of low boiling point is obtained, the presence of n-butyl... [Pg.165]

The experimental conditions necessary for the preparation of a solution of a diazonium salt, diazotisation of a primary amine, are as follows. The amine is dissolved in a suitable volume of water containing 2 5-3 equivalents of hydrochloric acid (or of sulphuric acid) by the application of heat if necessary, and the solution is cooled in ice when the amine hydrochloride (or sulphate) usually crystallises. The temperature is maintained at 0-5°, an aqueous solution of sodium nitrite is added portion-wise until, after allowing 3-4 minutes for reaction, the solution gives an immediate positive test for excess of nitrous acid with an external indicator—moist potassium iodide - starch paper f ... [Pg.590]

Alnminon (qualitative test for aluminum). The reagent consists of 0.1% solution of the ammonium salt of aurin tricarboxylic acid. A bright red precipitate, persisting in alkaline solution, indicates aluminum. [Pg.1187]

Alkali or alkaline-earth salts of both complexes are soluble in water (except for Ba2[Fe(CN)g]) but are insoluble in alcohol. The salts of hexakiscyanoferrate(4—) are yellow and those of hexakiscyanoferrate(3—) are mby red. A large variety of complexes arise when one or more cations of the alkah or alkaline-earth salts is replaced by a complex cation, a representative metal, or a transition metal. Many salts have commercial appHcations, although the majority of industrial production of iron cyanide complexes is of iron blues such as Pmssian Blue, used as pigments (see Pigments, inorganic). Many transition-metal salts of [Fe(CN)g] have characteristic colors. Addition of [Fe(CN)g] to an unknown metal salt solution has been used as a quaUtative test for those transition metals. [Pg.434]

Product Utilization. The principal appHcation for chromium phosphate coatings is as a paint base for painted aluminum extmsions and aluminum beverage can stock. In these appHcations, extremely demanding performance criteria are met by the chromium phosphate conversion coatings. As an example, the Architectural Aluminum Manufacturer s Association Voluntary Specification 605.2-92 requires humidity and salt spray testing for 3000 hours and allows only minimal incidence of paint failure after testing (26). [Pg.224]

Miscellaneous. Reductioa of a palladium salt by CO is the basis of a visual test for ambieat carboa moaoxide (227). Palladium compouads are used as photographic seasitizers (228). The low dimensional mixed valeace compouad Csq g3[Pd(S2C2(CN)2)] 0.5H2O behaves as a semimetal at room temperature (229). Palladium compouads isostmctural with poteat platiaum antitumor compounds have poor antitumor activity (230). [Pg.183]

The dibydrochloride salt is used as a photographic developer. It also is employed as an intermediate in the manufacture of fur dyes, in hair dyeing, as a reagent in testing for ammonia and formaldehyde, and as an oxygen scavenger in water to prevent boiler corrosion (173). [Pg.314]

Bunte salts have bacterial, insecticidal, and fungicidal properties, and are also used as chelating agents (qv) or surfactants (qv) (97,98). Bunte salts have been tested for preirradiation protection for mammals exposed to lethal radiation doses (99,100) (see Radioprotectiveagents). [Pg.32]

An enzymatic method (45), which is specific for the citrate moiety, can be used as a combined assay and identification test for citric acid and its common salts down to 20 ppm. [Pg.185]

If the solution is acidified and aUtde ferric sulfate added, ferric ferrocyanide [14038-43-8], Fe4[Fe(CN)g]2, is produced. This salt has a characteristic deep blue color, and the reaction may be used to test for the cyanide. [Pg.382]

Sa.lt Spray Tests. One of the older accelerated corrosion tests is the salt spray test (40). Several modifications of this imperfect test have been proposed, some of which are even specified for particular appHcations. The neutral salt spray test persists, however, especially for coatings that are anodic to the substrate and for coatings that are dissolved or attacked by neutral salt fog. For cathodic coatings, such as nickel on steel, the test becomes a porosity test, because nickel is not attacked by neutral salt fog. Production specifications that call for 1000 hours salt spray resistance are not practical for quahty acceptance tests. In these cases, the neutral salt spray does not qualify as an accelerated test, and faster results from different test methods should be sought. [Pg.151]


See other pages where Salts tests for is mentioned: [Pg.410]    [Pg.14]    [Pg.412]    [Pg.44]    [Pg.410]    [Pg.14]    [Pg.412]    [Pg.44]    [Pg.275]    [Pg.314]    [Pg.362]    [Pg.395]    [Pg.384]    [Pg.439]    [Pg.165]    [Pg.199]    [Pg.565]    [Pg.624]    [Pg.1059]    [Pg.585]    [Pg.223]    [Pg.364]    [Pg.473]    [Pg.481]    [Pg.254]    [Pg.111]    [Pg.555]    [Pg.377]   