Further Testing

It should be emphasised, that further tests will allow to obtain a higher precision of detectability of residual austenite, especially within the scope below 5%. [Pg.24]

The calibration curve of each rosetta strain gauge was so obtained and ftg.5 shows the sum of the principal stresses at the measuring points versus pressure inside the vessel. Further tests were carried out to obtain the calibration factor and to check that it remained constant on the whole scan area of the test surface. This was achieved through additional measurements using the SPATE system on fixed points on the surface located very close to the applied rosetta strain gauges. This procedure gave the following results ... [Pg.411]

Of course, under the same operating conditions, the higher the thickness the lower the stress level. Further tests were carried out to map the surface thickness distribution using an ultrasonic precision thickness gauge. It was so verified a deviation of the thickness up to 10% of the nominal value. [Pg.411]

Copper(II) ions in aqueous solution are readily obtained from any copper-containing material. The reactions with (a) alkali (p. 430), (b) concentrated ammonia (p 413) and (c) hydrogen sulphide (p. 413) provide satisfactory tests for aqueous copper(II) ions. A further test is to add a hexacyanoferrate(II) (usually as the potassium salt) when a chocolate-brown precipitate of copper(II) hexacyanoferrate(II) is obtained ... [Pg.416]

The last approximation is for finite At. When the equations of motions are solved exactly, the model provides the correct answer (cr = 0). When the time step is sufficiently large we argue below that equation (10) is still reasonable. The essential assumption is for the intermediate range of time steps for which the errors may maintain correlation. We do not consider instabilities of the numerical solution which are easy to detect, and in which the errors are clearly correlated even for large separation in time. Calculation of the correlation of the errors (as defined in equation (9)) can further test the assumption of no correlation of Q t)Q t )). [Pg.268]

If a turbid solution is obtained, suggesting the presence of a secondary alcohol but not excluding a tertiary alcohol, a further test with concentrated hydrochloric acid must be made. Mix 1 ml. of the alcohol with 6 ml. of concentrated hydrochloric acid, and observe the result —... [Pg.262]

Peroxide Formation. Except for the methyl alkyl ethers, most ethers tend to absorb and react with oxygen from the air to form unstable peroxides that may detonate with extreme violence when concentrated by evaporation or distillation, when combined with other compounds that give a detonable mixture, or when disturbed by heat, shock, or friction. Appreciable quantities of crystalline soHds have been observed as gross evidence for the formation of peroxides, and peroxides may form a viscous Hquid in the bottom of ether-fiHed containers. If viscous Hquids or crystalline soHds are observed in ethers, no further tests for the detection of peroxides are recommended. Several chemical and physical methods for detecting and estimating peroxide concentrations have been described. Most of the quaHtative tests for peroxides are readily performed and strongly recommended when any doubt is present (20). [Pg.427]

Give a eomparison for further tests to estimate power loss, e. To ensure that the guarantee point is defined by the test data,... [Pg.324]

The regenerator pressure fell by 28 mbar. This value was within the eontraetually agreed limits. Nevertheless, two further tests were performed with modified parameters. Five hours after beginning the optimization proeess, a test was performed in whieh the regenerator pressure dropped by just 8 mbar. This value is within the normal operating spread of the regenerator output pressure. [Pg.390]

A compatible blend should have good processing properties along with a smooth surface and cross-section. If needed, further tests on mechanical properties should be carried out on testing samples made from 2-mm films produced by compression molding. [Pg.142]

Hesitation continues until no pressure leak-off is observed. A further test of about 500 psi over the final injection pressure will indicate the end of the injection process. Usually, well-cementing perforations will tolerate pressures above the formation fracture pressure, but the risk of fracturing is increased. [Pg.1228]

I RECOMMEND that (due to age and condition) this installation be further tested after an interval of not more than.years... [Pg.159]

Interaction tests should be made on all unprotected structures in the vicinity of a proposed cathodic protection installation, and should be repeated annually or at some other suitable interval to ensure that alterations in the layout of plant or in the electrical conditions are taken into account. It is most convenient if the tests on all unprotected pipes or cables are made at the same time, the potential measurements being synchronised with the regular switching on and off of the protection current. It may then be convenient to continue with further tests to confirm that any remedial measures applied to one installation do not adversely affect other installations. [Pg.239]

When the test is to be made to predict the performance of a material in a particular service, the ideal procedure would be to have the surface of the test-pieces duplicate the surface of the material as it would be used. Here, however, a complication is presented by the fact that materials in service are commonly used in several forms with different conditions of surface. Where the number of materials to be compared is large, it will usually be impractical to test all the conditions of surface treatment of possible interest. The best practical procedure, then, is to choose some condition of surface more or less arbitrarily selected to allow the materials to perform near the upper limits of their ability. If all the materials to be tested are treated in this way, and preferably with uniform surface treatment, the results of the test will indicate the relative abilities of the different materials to resist the test environment when in a satisfactory condition of surface treatment. Then, if it should be considered prudent or desirable to do so, the most promising materials can be subjected to further tests in a variety of surface conditions so that any surface sensitivity can be detected. [Pg.979]

The findings from two long term test runs in the SASOL plant relevant to catalyst life under design conditions in a commercial methane synthesis plant have already been published (3). This paper reports further test results from both demonstration units concerning the effect of certain reaction parameters which are the basis for flexibility and operability of the Lurgi methanation scheme. [Pg.123]

By contrast, the rate-acidity profiles for nitration of 3-nitro-4-pyridone, 3-and 5-methyl-2-pyridone and l,5-dimethyl-2-pyridone resemble each other and differ from the above-indicated reaction upon the free base, and correction of the observed rates to allow for the concentration of free base actually present gave rate-acidity profiles of the expected form the corrected entropies of activation then turned out to be positive. Furthermore, if the logarithms of the corrected rate coefficients obtained in media of low acidity were plotted against +log aHlQ, then slopes of near unity were obtained (see above, p. 18), but not otherwise. A similar result was obtained from the nitration data for 4-pyridone in media of low acidity suggesting that here it reacts as the free base. A further test which was applied was to calculate the concentration of nitronium ions in the various media and to correct the observed rate coefficients for this the logarithms of these coeffi-... [Pg.21]

Pauling, L. Bond Angles in Transition Metal Tetracarbonyl Compounds A Further Test of the Theory of Hybrid Bond Orbitals Proc. Natl. Acad. Sci. (USA) 1978, 75, 569-572. [Pg.340]

A further test of adequacy is the plot of observed vs. fitted values which is shown in Figure 5. The points generally fall along the reference line for a perfect fit. Further, the deviations from the reference line appear to be randomly distributed. [Pg.92]

In a further test, increase the grid size to 100 x 100, set Pr(AB) at 1.0, and repeat the process. This test reveals the influence of concentration on the rate, since the two ingredients now have a much larger territory to roam about, making them in effect less concentrated. Compare your results with the results from the Pr(AB) =1.0 part of Study 8. lb. [Pg.129]


See other pages where Further Testing is mentioned: [Pg.882]    [Pg.43]    [Pg.208]    [Pg.49]    [Pg.551]    [Pg.148]    [Pg.198]    [Pg.122]    [Pg.261]    [Pg.99]    [Pg.16]    [Pg.249]    [Pg.2045]    [Pg.74]    [Pg.368]    [Pg.516]    [Pg.373]    [Pg.19]    [Pg.381]    [Pg.592]    [Pg.158]    [Pg.908]    [Pg.1039]    [Pg.354]    [Pg.31]    [Pg.117]    [Pg.283]    [Pg.216]    [Pg.95]    [Pg.126]    [Pg.193]    [Pg.193]   