Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Reduction analytical

In the tris(2,2 -bypyridyl)ruthenium(n) [Ru (bipy) ] system, an orange emission centered at 610 nm results from the excited state [Ru (bipy) " ]. Central to the utilization of this type of chemiluminescence is the generation the reactive oxidant tris(2,2 -by-pyridyl)ruthenium(III) [Ru(bipy) ] and its subsequent reaction with a reductive analyte, as shown in reaction [VIII] ... [Pg.534]

In the presence of many metal ions, diorthohydroxyazo dyes exhibit two polarographic reduction waves, the first due to free dye and the second to metal-dye complex. Highly sensitive analytical methods based on this principle have been developed for example, Ni or Fe may be determined in the presence of an excess of aluminum thank to thiazolylazo derivatives (563). [Pg.153]

Several types of reactions are commonly used in analytical procedures, either in preparing samples for analysis or during the analysis itself. The most important of these are precipitation reactions, acid-base reactions, complexation reactions, and oxidation-reduction reactions. In this section we review these reactions and their equilibrium constant expressions. [Pg.139]

In electrogravimetry the analyte is deposited as a solid film on one electrode in an electrochemical cell. The oxidation of Pb +, and its deposition as Pb02 on a Pt anode is one example of electrogravimetry. Reduction also may be used in electrogravimetry. The electrodeposition of Cu on a Pt cathode, for example, provides a direct analysis for Cu +. [Pg.234]

A titration in which the reaction between the analyte and titrant is an oxidation/reduction reaction. [Pg.331]

The percentage of current that actually leads to the analyte s oxidation or reduction. [Pg.496]

In coulometry, current and time are measured, and equation 11.24 or equation 11.25 is used to calculate Q. Equation 11.23 is then used to determine the moles of analyte. To obtain an accurate value for N, therefore, all the current must result in the analyte s oxidation or reduction. In other words, coulometry requires 100% current efficiency (or an accurately measured current efficiency established using a standard), a factor that must be considered in designing a coulometric method of analysis. [Pg.496]

Controlled-potential coulometry also can be applied to the quantitative analysis of organic compounds, although the number of applications is significantly less than that for inorganic analytes. One example is the six-electron reduction of a nitro group, -NO2, to a primary amine, -NH2, at a mercury electrode. Solutions of picric acid, for instance, can be analyzed by reducing to triaminophenol. [Pg.502]

Controllcd-Currcnt Coulomctry The use of a mediator makes controlled-current coulometry a more versatile analytical method than controlled-potential coulome-try. For example, the direct oxidation or reduction of a protein at the working electrode in controlled-potential coulometry is difficult if the protein s active redox site lies deep within its structure. The controlled-current coulometric analysis of the protein is made possible, however, by coupling its oxidation or reduction to a mediator that is reduced or oxidized at the working electrode. Controlled-current coulometric methods have been developed for many of the same analytes that may be determined by conventional redox titrimetry. These methods, several of which are summarized in Table 11.9, also are called coulometric redox titrations. [Pg.503]

Coupling the mediator s oxidation or reduction to an acid-base, precipitation, or complexation reaction involving the analyte allows for the coulometric titration of analytes that are not easily oxidized or reduced. For example, when using H2O as a mediator, oxidation at the anode produces H3O+... [Pg.503]

If the oxidation or reduction of H2O is carried out externally using the generator cell shown in Figure 11.25, then H3O+ or OH can be dispensed selectively into a solution containing a basic or acidic analyte. The resulting reaction is identical to that in an acid-base titration. Coulometric acid-base titrations have been used for... [Pg.503]

Sensitivity For a coulometric method of analysis, the calibration sensitivity is equivalent to tiF in equation 11.25. In general, coulometric methods in which the analyte s oxidation or reduction involves a larger value of n show a greater sensitivity. [Pg.508]

Sign Conventions Since the reaction of interest occurs at the working electrode, the classification of current is based on this reaction. A current due to the analyte s reduction is called a cathodic current and, by convention, is considered positive. Anodic currents are due to oxidation reactions and carry a negative value. [Pg.510]

Residual Current Even in the absence of analyte, a small current inevitably flows through an electrochemical cell. This current, which is called the residual current, consists of two components a faradaic current due to the oxidation or reduction of trace impurities, and the charging current. Methods for discriminating between the faradaic current due to the analyte and the residual current are discussed later in this chapter. [Pg.513]

Correcting for Residual Current In any quantitative analysis the signal due to the analyte must be corrected for signals arising from other sources. The total measured current in any voltammetric experiment, itot> consists of two parts that due to the analyte s oxidation or reduction, and a background, or residual, current, ir. [Pg.521]

In stripping voltammetry the analyte is first deposited on the electrode, usually as the result of an oxidation or reduction reaction. The potential is then scanned, either linearly or by using potential pulses, in a direction that removes the analyte by a reduction or oxidation reaction. [Pg.533]

The concentration of chromic acid can be determined from its reduction by alcohols under conditions when the kinetics are pseudo-first-order in analyte. One approach is to monitor the absorbance of the solution at a wavelength of 355 nm. A standard solution of 5.1 X lO " M chromic acid yields absorbances of 0.855 and 0.709 at, 100 s and 300 s, respectively, after the reaction s initiation. When a sample with an unknown amount of chromic acid is analyzed under... [Pg.661]

A schematic illustration of a typical inlet apparatus for separating volatile hydrides from the analyte solution, in which they are generated upon reduction with sodium tetrahydroborate. When the mixed analyte solution containing volatile hydrides enters the main part of the gas/liquid separator, the volatiles are released and mix with argon sweep and makeup gas, with which they are transported to the center of the plasma. The unwanted analyte solution drains from the end of the gas/liquid separator. The actual construction details of these gas/liquid separators can vary considerably, but all serve the same purpose. In some of them, there can be an intermediate stage for removal of air and hydrogen from the hydrides before the latter are sent to the plasma. [Pg.100]

Many of the impurities are much lower than the values shown in Table 3, but these analytical lower limits are typical and more than sufficient for all but special appHcations. Zirconium content can be from 0.01 to 4.5%, and is typically 0.5—2%, but this is a function of how far the separation process was carried, not a function of the reduction or refining processes. [Pg.442]

Other routes for hydroxybenzaldehydes are the electrolytic or catalytic reduction of hydroxybenzoic acids (65,66) and the electrolytic or catalytic oxidation of cresols (67,68). (see Salicylic acid and related compounds). Sahcylaldehyde is available in drums and bulk quantities. The normal specification is a freezing point minimum of 1.4°C. 4-Hydroxybenzaldehyde is available in fiber dmms, and has a normal specification requirement of a 114°C initial melting point. More refined analytical methods are used where the appHcation requires more stringent specifications. [Pg.507]

Analytical and Test Methods. o-Nitrotoluene can be analyzed for purity and isomer content by infrared spectroscopy with an accuracy of about 1%. -Nitrotoluene content can be estimated by the decomposition of the isomeric toluene diazonium chlorides because the ortho and meta isomers decompose more readily than the para isomer. A colorimetric method for determining the content of the various isomers is based on the color which forms when the mononitrotoluenes are dissolved in sulfuric acid (45). From the absorption of the sulfuric acid solution at 436 and 305 nm, the ortho and para isomer content can be deterrnined, and the meta isomer can be obtained by difference. However, this and other colorimetric methods are subject to possible interferences from other aromatic nitro compounds. A titrimetric method, based on the reduction of the nitro group with titanium(III) sulfate or chloride, can be used to determine mononitrotoluenes (32). Chromatographic methods, eg, gas chromatography or high pressure Hquid chromatography, are well suited for the deterrnination of mononitrotoluenes as well as its individual isomers. Freezing points are used commonly as indicators of purity of the various isomers. [Pg.70]

Ozone can be analyzed by titrimetry, direct and colorimetric spectrometry, amperometry, oxidation—reduction potential (ORP), chemiluminescence, calorimetry, thermal conductivity, and isothermal pressure change on decomposition. The last three methods ate not frequently employed. Proper measurement of ozone in water requites an awareness of its reactivity, instabiUty, volatility, and the potential effect of interfering substances. To eliminate interferences, ozone sometimes is sparged out of solution by using an inert gas for analysis in the gas phase or on reabsorption in a clean solution. Historically, the most common analytical procedure has been the iodometric method in which gaseous ozone is absorbed by aqueous KI. [Pg.503]

Diacyl peroxides have been reduced with a variety of reduciag agents, eg, lithium aluminum hydride, sulfides, phosphites, phosphines, and haUde ions (187). Hahdes yield carboxyUc acid salts (RO) gives acid anhydrides. With iodide ion and certain trivalent phosphoms compounds, the reductions are sufftcientiy quantitative for analytical purposes. [Pg.124]


See other pages where Reduction analytical is mentioned: [Pg.467]    [Pg.378]    [Pg.28]    [Pg.163]    [Pg.467]    [Pg.378]    [Pg.28]    [Pg.163]    [Pg.253]    [Pg.341]    [Pg.341]    [Pg.343]    [Pg.343]    [Pg.497]    [Pg.499]    [Pg.508]    [Pg.508]    [Pg.510]    [Pg.771]    [Pg.777]    [Pg.45]    [Pg.53]    [Pg.331]    [Pg.280]    [Pg.224]    [Pg.298]    [Pg.304]    [Pg.103]    [Pg.132]    [Pg.200]    [Pg.395]   
See also in sourсe #XX -- [ Pg.43 , Pg.88 ]




SEARCH



Analyte reduction

© 2024 chempedia.info