Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Matrix types

Thus, the existence of a (matrix-type) phase g represents the pure-gauge case and the nonexistence of g represents the nonpure YM field case, which cannot be tiansformed away by a gauge. [Pg.148]

In Situ Bioremediation. In situ bioremediation can be an aerobic or anaerobic process, or a combination of the two. In designing an in situ bioremediation system, one should consider the types of microorganisms available (naturally in place or added), the stmctural and chemical makeup of the soil matrix, types of contaminants, oxygen and nutrient addition and distribution, and temperature. These factors are discussed prior to introducing the individual techniques for in situ bioremediation. [Pg.170]

The most familiar of the C-frame, matrix-type industrial magnetic separators are the Carpco, Eriez, Readings, and Jones devices. The Carpco separator employs steel balls as a matrix, Eriez uses a combination of expanded met matrices, and the Readings and Jones separators have grooved-plate matrices. Capacities for this type of unit are reported to up to 180 t/h (in the case of Brazdian-hematite processing). [Pg.1798]

Binders improve the strength of compacts through increased plastic deformation or chemical bonding. They may be classified as matrix type, film type, and chemical. Komarek [Chem. Eng., 74(25), 154 (1967)] provides a classification of binders and lubricants used in the tableting of various materials. [Pg.1891]

Yet another strength of SNMS is the ability to measure elemental concentrations accurately at interfaces, as illustrated in Figure 8, which shows the results of the measurement of N and O in a Ti thin film on Si. A substantial oxide film has formed on the exposed Ti surface. The interior of the Ti film is free of N and O, but significant amounts of both are observed at the Ti/Si interface. SNMS is as sensitive to O as to N, and both the O and N contents are quantitatively measured in all regions of the structure, including the interface regions. Quantitation at the interface transition between two matrix types is difficult for SIMS due to the matrix dependence of ion yields. [Pg.583]

In the development of a SE-HPLC method the variables that may be manipulated and optimized are the column (matrix type, particle and pore size, and physical dimension), buffer system (type and ionic strength), pH, and solubility additives (e.g., organic solvents, detergents). Once a column and mobile phase system have been selected the system parameters of protein load (amount of material and volume) and flow rate should also be optimized. A beneficial approach to the development of a SE-HPLC method is to optimize the multiple variables by the use of statistical experimental design. Also, information about the physical and chemical properties such as pH or ionic strength, solubility, and especially conditions that promote aggregation can be applied to the development of a SE-HPLC assay. Typical problems encountered during the development of a SE-HPLC assay are protein insolubility and column stationary phase... [Pg.534]

If the sample and standard have essentially the same matrices (e.g., air particulates or river sediments), one can go through the total measurement process with both the sample and the standard in order to (a) check the accuracy of the measurement process used (compare the concentration values obtained for the standard with the certified values) and (b) obtain some confidence about the accuracy of the concentration measurements on the unknown sample since both have gone through the same chemical measurement process (except sample collection). It is not recommended, however, that pure standards be used to standardize the total chemical measurement process for natural matrix type samples chemical concentrations in the natural matrices could be seriously misread, especially since the pure PAH probably would be totally extracted in a given solvent, whereas the PAH in the matrix material probably would not be. All the parameters and matrix effects. Including extraction efficiencies, are carefully checked in the certification process leading to SRM s. [Pg.119]

The release of a compound from the food matrix in which it is incorporated is a determining process for its bioavailability and is largely influenced by the physicochemical characteristics of the compound, the type of food matrix, the subcellular location of the compound in plant tissues, and the food processing. The, food matrix type greatly influences the compound bioaccessibility. [Pg.158]

The revised database holds over 23 000 analyte values for 660 measurands and 1670 reference materials produced by 56 different producers, from 22 countries. The database is restricted to natural matrix materials (i.e. made from naturally occurring materials, excluding calibration standards manufactured from pure chemicals). Information has been extracted from the relevant certificates of analysis, information sheets, and other reports provided by the reference material producers. As a general rule, the authors have only included in the compilation reference materials for which a certificate of analysis or similar documentation is on file. Information included in the survey is on values for measurands determined in reference materials, producers, suppliers, the cost of the materials, the unit size supplied, and the recommended minimum weight of material for analysis, if available. The new searchable database has been designed to help analysts to select reference materials for quality assurance purposes that match as closely as possible, with respect to matrix type and concentrations of the measurands of interest and their samples to be analyzed see Table 8.3. [Pg.264]

The user can find suitable materials in a number of different ways. For instance any of the above measurands can be chosen and a search made within a specific matrix type. A list of the measurand values in all materials of the selected matrix classification sorted by decreasing concentration will be produced, including the uncertainties in percent, the certification status and the material identification code. Other search methods are possible, selection by material gives a table with values of all measurands in the chosen material in alphabetical order and additional information about the price, the unit size, the issuing date, the supphers and the exact material name. A further option is to list all materials from a producer. [Pg.265]

Reproducibility in the context of Directive 96/46/EC is defined as a validation of the repeatability of recovery, from representative matrices at representative levels, by at least one laboratory, which is independent of the laboratory which initially validated the study. This independent laboratory may be within the same company, but may not be involved in the development of the method. This concept of independent laboratory validation (ILV) substitutes the conduct of interlaboratory trials (e.g., according to ISO 5725) because the resources are not available taking into consideration the high number of a.i., matrix types and concentration levels which must be validated in the registration procedure. [Pg.22]

In the future, the enforcement of feedingstuffs will be more important because the MRLs established for food become partly obligatory for feed also. Validation concepts for this matrix must be developed in collaboration with laboratories obliged to control feedingstuffs, considering the approach of four matrix types for food crops mentioned in Section 4. [Pg.36]

To demonstrate the validity of an analytical method, data regarding working range/ calibration, recovery, repeatability, specificity and LOQ have to be provided for each relevant sample matrix. Most often these data have to be collected from several studies, e.g., from several validation reports of the developer of the method, the independent laboratory validation or the confirmatory method trials. If the intended use of a pesticide is not restricted to one matrix type and if residues are transferred via feedstuffs to animals and finally to foodstuffs of animal origin, up to 30 sets of the quality parameters described above are necessary for each analyte of the residue definition. Table 2 can be used as a checklist to monitor the completeness of required data. [Pg.102]

Origin of sample Matrix type Main study Independent lab. validation" Confirmatory method"... [Pg.102]

Although we speak generally of validated methods , only the performance of a method applied to a particular range of materials (matrices) is reported. The possibility of matrix interferences or the efficiency of cleanup steps may vary with matrix type. For that reason, methods should be validated in all matrix types, which differ significantly. In the context of the validation of enforcement methods by applicants, significant difference is not a well defined term. To avoid any dispute about completeness of validation, five material types had been selected for crops, which usually... [Pg.106]

From time to time in older studies, the validity of the method was not tested with all commodity groups. Nevertheless, these studies can be used if the omitted matrix types are tested additionally in the independent laboratory validation. [Pg.107]

In contrast to many other validation protocols, the description of the NMKL validation process starts with the protocol of planned validation. This protocol should include, e.g., the needs of the client, available equipment, the chemical form in which the analyte occurs (i.e., in pesticide analysis the residue definition), matrix types, the availability of reference materials and the working range. Consequently, an extra paragraph is dedicated to the requirements for the documentation of validation results, which refers to the rules in Section 5.4.4 of EN 45001 (amended by ISO 17025). [Pg.122]

Mechanism Sorbent Analyte type Matrix type Analyte eluent... [Pg.126]

On-line SFE-SFC method development for validated quantitative analysis of PP/(Irganox 1010/1076, Tinuvin 327) has been reported [93]. SFE conditions required optimisation of extraction time and pressure, matrix type (particle or film) and matrix parameters (particle size, film thickness, sample weight). About 30% of extracts were lost during collection. Very poor recoveries (20-25 %) were reported from ground samples (particle size 100 p,m dependent recoveries of 45-70% for 30-p.m-thick films. Biicherl... [Pg.444]

Fig. 6. Diagrammatic (two-dimensional) representation of different modes of lattice inclusions involving coordinative (H-bond) interactions (indicated by broken lines) (a) cross-linked matrix type of inclusion (host-host interaction, true clathrate) (b) coordinatoclathrate type of inclusion (coordinative host-guest interaction, coordination-assisted clathrate)... Fig. 6. Diagrammatic (two-dimensional) representation of different modes of lattice inclusions involving coordinative (H-bond) interactions (indicated by broken lines) (a) cross-linked matrix type of inclusion (host-host interaction, true clathrate) (b) coordinatoclathrate type of inclusion (coordinative host-guest interaction, coordination-assisted clathrate)...
Extensions of BCS beyond the oral IR area has also been suggested, for example to apply BCS in the extended-release area. However, this will provide a major challenge since the release from different formulations will interact in different ways with in vitro test conditions and the physiological milieu in the gastrointestinal tract. For example, the plasma concentration-time profile differed for two felodipine ER tablets for which very similar in vitro profiles had been obtained, despite the fact that both tablets were of the hydrophilic matrix type based on cellulose derivates [70], This misleading result in vitro was due to interactions between the gel strength of the matrix and components in the dissolution test medium of no in vivo relevance. The situation for ER formulations would be further complicated by the need to predict potential food effects on the drug release in vivo. [Pg.516]

Precision studies should mirror the operating conditions used during routine use of the method. For example, the range of operating conditions, such as the variation in the laboratory temperature, needs to reflect that which will occur in practice. In addition the same number of replicate measurements per test portion should be used. Where a range of analytes is measured by a single method (e.g. pesticides by GC or trace elements by ICP-MS), or where different matrix types are encountered, it is necessary to determine the precision parameters... [Pg.80]

The hypothesis that stress can modulate MMP expression is also supported by studies in mice. Using social isolation as a stressor, the mRNA levels of MMP-2, MMP-9, matrix-type matrix metalloproteinase-1 (MT1-MMP), and urokinase-type plasminogen activator were higher in the tumor and liver tissues of the isolated mice than in control mice.91 Furthermore, a recent study has shown that restraint stress causes an increase in expression of the plasminogen activator inhibitor-1, another key player in the plas-minogen/plasmin enzyme system in mice.92 As these enzymes have been described to have functions besides their role in ECM remodeling,93 studies on stress-related effects on MMP/TIMP balance have implications in the relationship between stress and cancer initiation and progression.. [Pg.519]

The standard curve should be three levels, typically ranging from 25 to 2,500 ng/mL (may be lower or higher as needed). Each standard is 10 times the one below (a typical set is 25, 250, and 2500 ng/mL). The matrix of the calibration curve should be from the same animal species and matrix type as the samples. [Pg.214]

Do you use Certified Reference Materials (CRMs), and if so, how For example, specify the concentrations) matrix type(s) etc. [Pg.108]

Do you use In-House Reference Materials (IHRM) and how are they obtained For example, specify the concentration(s) matrix type(s). [Pg.108]

Several major matrix types are found in marine particles and sediments. Marine organisms surround themselves with tough polymeric organic cell walls and/or with opal or calcium carbonate tests. These contrasting matrices respond differently to various analytical methods. In sediments, the remains of these organisms combine with clay minerals to form a heterogeneous mixture. In this section, the influence of these matrices on analyte quantification are discussed. [Pg.72]


See other pages where Matrix types is mentioned: [Pg.301]    [Pg.42]    [Pg.147]    [Pg.535]    [Pg.602]    [Pg.1053]    [Pg.62]    [Pg.102]    [Pg.105]    [Pg.106]    [Pg.107]    [Pg.108]    [Pg.109]    [Pg.129]    [Pg.130]    [Pg.83]    [Pg.87]    [Pg.93]    [Pg.198]    [Pg.4]    [Pg.206]    [Pg.35]   
See also in sourсe #XX -- [ Pg.353 ]




SEARCH



© 2024 chempedia.info