Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Laboratory evaluation equipment

In the last entry in Table III more than 50 samples were extracted in an experiment surveying the performance of laboratory robotic equipment. These included 2.0 gram samples of soils extracted with pure C02,2.5 gram samples of a reverse phase material extracted with C02 and mixtures of C02 with various modifiers, 2.0 gram samples of ground coffee plus aliquots of modifiers dispersed on the samples within the sample thimble extracted with pure CO and 20 microliter aliquots of performance evaluation standard (PES, octadecane in isooctane) on simple matrices extracted with pure C02. The variety of analytes and complex matrices along with the number of different runs clearly show that the instrumentation is reliable. [Pg.279]

NMR is not a technique for everyday use in the biochemistry laboratory. The equipment needed for protein structure determination is expensive, and detailed expertise is needed to evaluate and interpret the results. For these reasons NMR as a tool in the study of biomolecular structure and function is confined to a limited number of specialist centres. [Pg.263]

Atkins, E.L., L.D. Anderson, and T.O. Tuft. 1954. Equipment and technique used in laboratory evaluation of pesticide dusts in toxicological studies with honeybees. J. Econ. Entomol. 47 965-969. [Pg.409]

Figure 20. Equipment for laboratory evaluation of ion exchange resins. Figure 20. Equipment for laboratory evaluation of ion exchange resins.
Samples of punch-and-die pressing can be produced in a variety of home made or purchased small machines. The previously mentioned force/pressure test stands (Fig. 11.18), which may also use hydraulic actuation with hand or motor pumps, can be applied in connection with home made punch-and-die arrangements. Many laboratories are equipped with automatically or hand operated hydraulic laboratory presses, for example as shown in Fig. 11.20 (see also Fig. 8.92, Section 8.4.3). From the suppliers of such machines a large number of simple or sometimes highly sophisticated and automated presses are available. They are used for the determination of a variety of strength and force or pressure related product characteristics and, although the densification and compaction mechanisms are quite different from those of roller presses and can not be correlated, punch-and-die compacts are often made and evaluated to preliminarily investigate the compactibility of different feed materials or powder mixtures and to determine the type and amount of potential binders. [Pg.481]

Another modular system is often called laboratory equipment it can be used for small scale production and for the laboratory evaluation of small samples. Fig. 11.26 depicts the design and some of the accessories. In the most simple execution a hopper feeds a pair of rollers which are driven by a hand crank. The rollers can be solid and may be equipped with compacting or briquetting surfaces (see Section 8.4.3) or two perforated, geared, intermeshing pelleting rolls (see Section 8.4.2) are installed to accomplish medium pressure extrusion. In a modular fashion the rollers can be motorized, screw feeders can be added, and the rolls may be oriented vertical or horizontal or in any other direction. As shown in the photographs of Fig. 11.27 the roller frame can be totally enclosed for dust control if toxic or hazardous materials are processed. A panel includes controls and instrumentation for data display and collection. [Pg.488]

It has been stated several times before that the development of all agglomeration techniques is still more an art than a science. After concluding a pre-selection, which is a desk job but is based on laboratory evaluations of the feed solid s properties, it becomes necessary to carry-out additional investigations, particularly, for example, to determine if and potentially what kind of a binder must be added and how much of it is required. Then, tests with actual equipment must be conducted to find limitations in regard to capacity and product size, shape, and characteristics. Needs of peripheral equipment, for post-treatment and of closed loop processing and recirculation must be also evaluated. [Pg.958]

The aim of any laboratory technique is to simulate the conditions that are likely to occur in a heat exchanger, particularly in terms of velocity surface temperature and residence time. Wherever possible the fluid used in the laboratory investigation will be that used in the actual process, but this may not be possible due to the difficulties of maintaining chemical and physical conditions in the laboratory equipment the same as those present in the full scale plant. It is not within the scope of this book to provide a comprehensive list of the problems associated with laboratory evaluation because each system will have different characteristics. It is possible however, to provide some examples of where difficulties are likely to occur as a guide, and these may be summarised as follows ... [Pg.481]

Nowadays, many analytical laboratories are equipped with an infrared (IR) and a Raman spectrometer, be it a dispersive device or a Fourier transform (FT) instrument. Raman and IR spectra provide images of molecular vibrations that complement each other and thus both spectroscopic techniques together are also called vibrational spectroscopy. The concerted evaluation of both spectra gives more information about the molecular structure than when they are evaluated separately. [Pg.1]

Prudent execution of experiments requires not only sound judgment and an accurate assessment of the risks involved in laboratory work, but also the selection of appropriate work practices to reduce risk and protect the health and safety of the laboratory workers as well as the public and the environment. Chapter 3 provides specific guidelines to enable laboratory workers to evaluate the hazards and assess the risks associated with laboratory chemicals, equipment, and operations. Chapter 4 demonstrates how to control those risks when managing the inventory of chemicals in the laboratory. How the protocols outlined in Chapter 3 are put to use in the execution of a carefully planned experiment is the subject of Chapter 5. [Pg.85]

Other authors evaluated the blank of the instrument (instrumentation potential PFC contamination) through direct injection of pure methanol into the UHPLC-MS/ MS system [2], Laboratory disposable equipment was solicited in methanol and analyzed for PFCs [50], In other cases, all the materials were decontaminated by rinsing with ultrapure water and methanol [31], MilliQ water and MilliQ apparatus were tested for contamination [48], To choose the purest ultrapure water and solvents from various suppliers, 50 mL of solvent were evaporated to dryness and reconstituted in 200 liL of methanol. In many samples, the presence of detectable amounts of PFCs, in particular PFHxA, PFOA, and PFDA at concentrations ranging from 0.1 to 0.4 pg/ mL was evidenced [49],... [Pg.312]

Color labs are outfitted with laboratory size equipment that simulates the larger machines used for production internally and by their customers. Typical processing equipment found in the lab are small extruders, two-roll mills, ban-burry mills, and media mills. Small rotational, injection and blow molding machines are used to duplicate the customers process. Instruments and computers are required for testing physical properties and color. Most labs have a computer-controlled color measuring system and a light booth to evaluate color. The spectrophotometer with computer is initially used to assist in colorant formulation and later as a quality control (QC) tool to provide certification of the quahty of match to standard. The light booth provides a standardized set of conditions to visually observe color and appearance. [Pg.1589]

A technological task exists where the lumps of Fe-B ore with low, medium and high B concentrations have to be identified in an online regime. The traditional technology for boron real time detection involves the onUne determination of BIO concentration via neutron absorption. However, it is not easy-to-implement technology because of safety issues. The potential of LIBS sorting was evaluated using laboratory scale equipment. [Pg.519]


See other pages where Laboratory evaluation equipment is mentioned: [Pg.1075]    [Pg.1075]    [Pg.84]    [Pg.161]    [Pg.25]    [Pg.277]    [Pg.20]    [Pg.305]    [Pg.88]    [Pg.171]    [Pg.84]    [Pg.313]    [Pg.26]    [Pg.305]    [Pg.329]    [Pg.305]    [Pg.305]    [Pg.78]    [Pg.261]    [Pg.175]    [Pg.399]    [Pg.479]    [Pg.2]    [Pg.531]    [Pg.63]    [Pg.41]    [Pg.134]    [Pg.176]    [Pg.56]    [Pg.170]    [Pg.475]    [Pg.424]    [Pg.383]    [Pg.1081]    [Pg.155]    [Pg.444]    [Pg.82]    [Pg.106]   
See also in sourсe #XX -- [ Pg.104 ]




SEARCH



Equipment laboratory

Evaluation equipment

Laboratory evaluation

© 2024 chempedia.info