Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fused-silica capillary columns preparation

CZE has been employed for the analysis of another set of dyes in foodstuffs. The chemical structures, numbers and names of the dyes included in the investigation are listed in Fig. 3.142. A fused-silica capillary column of 57 cm length (50 cm effective length 75 jum i.d.) was employed for the separations. The capillary was conditioned by 1.0 M NaOH for 20 min followed by 10 min wash with water and 10 min wash with the running buffer. The buffer was prepared by adding NaOH to 10 mM phosphoric acid to reach pH 11.0. The capillary was thermostated at 25°C and the separation voltage was 20 kV. A hydrodynamic injection mode was applied (0.5 psi, 4 s, 21 nl) and spectra of... [Pg.520]

The solution, 10 pL, prepared as outlined in Note 18 was loaded an a Chirasil-Val fused-silica capillary column of Machery-Nagel (25 m, 0.4 mm) in a Carlo-Erba-Fraktovap 4160 HR GC. After 5 min at 160°C, the column temperature was increased by 2°C per min up to 200°C. [Pg.187]

Determination of CholesteroL For meat extraction, the procedures for determining the cholesterol of extracted lipid samples were described Chao et al. (2i). For edible beef tallow extraction, the preparation of samples for cholesterol content was based on the AOAC (22) method Section 28.110. The prepared sample was then injected into a Supelco SPB-1 fused silica capillary column of 30 meters x 032 mm i.d. in a Varian Model 3700 gas chromatograph equipped with dual flame ionization detectors. The initial holdup time was 4 min at 270°C and then programmed to a temperature of 300°C at a ramp rate of 10°C/min. Helium flow rate and split ratio were 13 ml and 50 1, respectively, while the injector/detector temperature was 310°C. [Pg.121]

Capillary gas chromatography (GC) using modified cyclodextrins as chiral stationary phases is the preferred method for the separation of volatile enantiomers. Fused-silica capillary columns coated with several alkyl or aryl a-cyclo-dextrin, -cyclodextrin and y-cyclodextrin derivatives are suitable to separate most of the volatile chiral compounds. Multidimensional GC (MDGC)-mass spectrometry (MS) allows the separation of essential oil components on an achiral normal phase column and through heart-cutting techniques, the separated components are led to a chiral column for enantiomeric separation. The mass detector ensures the correct identification of the separated components [73]. Preparative chiral GC is suitable for the isolation of enantiomers [5, 73]. [Pg.73]

Figure D1.2.2 Sample GC chromatogram of the FAME from butter fat (Sweet Cream Butter, Wisconsin Grade AA, Roundy s, Milwaukee, Wise.) prepared using the sodium methoxide method (see Basic Protocol 2). Equipment DB-23 fused silica capillary column, 30 m x 0.32 mm i.d., 0.25 pm film thickness, FID detector. Temperature, injector 225°C detector 250°C. Column (oven) temperature program 100°C initial, hold 4 min, ramp to 198°C at 1.5°C/min, hold 10 min. Total run time was 80 min. Split injection. Figure D1.2.2 Sample GC chromatogram of the FAME from butter fat (Sweet Cream Butter, Wisconsin Grade AA, Roundy s, Milwaukee, Wise.) prepared using the sodium methoxide method (see Basic Protocol 2). Equipment DB-23 fused silica capillary column, 30 m x 0.32 mm i.d., 0.25 pm film thickness, FID detector. Temperature, injector 225°C detector 250°C. Column (oven) temperature program 100°C initial, hold 4 min, ramp to 198°C at 1.5°C/min, hold 10 min. Total run time was 80 min. Split injection.
A stereoselective GC method for determination of etodolac enantiomers in human plasma and urine was first reported as a preliminary method [35], and then as a validated method [36]. Sample preparation involved addition of (S)-(+)-naproxen (internal standard) and sodium hydroxide to diluted plasma or urine. The samples were washed with diethyl ether, acidified with hydrochloric acid, and extracted with toluene. ( )-(+)-naproxen was used as a derivatizing agent to form diastereomeric derivatives of etodolac. The gas chromatograph system used in this work was equipped with fused-silica capillary column (12 m x 0.2 mm i.d.) coated with high-performance cross-linked methylsilicone film (thickness 0.33 pm) and a nitrogen-phosphorous detector. The operating conditions were injector 250°C detector 300°C column 100-260°C (32 °C/min). [Pg.139]

Procedure Inject 1-pL aliquots of the Standard Preparation and the Sample Preparation into a gas chromatograph equipped with a split injector, a flame-ionization detector, and a 25 -m fused silica capillary column coated with a 2-pm film of 7% cyanopropyl-7% phenyl-85% methyl-1% vinylpolysiloxane (CP-Sil 19 CB, Chrompack Middelburg, or equivalent). Maintain the column at 100°, raising the temperature at 8°/min to a final temperature of 300°. Set the injector temperature to 270°and the detector temperature to 270°. Use a mixture of helium and methane, at a split ratio of 1 100, as the carrier gas, flowing at 120 mL/ min. Run the chromatogram for 27 min. [Pg.23]

A Hewlett Packard 5880-A gas chromatograph equipped with a flame ionization detector, a 5880-A series level four computerized data system and a DB-5 (30 m x 0.25 mm I.D.) fused silica capillary column (J W Scientific, Folsom, CA) were used. Puree was centrifuged at 10,000 x g and the supernatant was injected onto the column (direct aqueous injection). Ultrafiltered juice was injected directly with no sample preparation. Sample size in all cases was 5uL split 15 1 with helium as the carrier gas at a flow rate of 1 ml/min. The oven temperature was held at 60°C for the initial seven minutes of the injection time. It was then increased to 200°C at a rate of 5°C/min and was held there for twenty five minutes. Total volatiles were obtained by summation of integrated peak areas on the chromatograms. Percent areas of each peak were also calculated. [Pg.349]

In preparative-scale (10 M 1-naphthol) experiments, an Ace-Hanovia 450-W medium-pressure mercury arc was used with a Pyrex filter sleeve and a magnetically stirred Ace water-cooled reaction vessel. In experiments involving rose bengal as a sensitizer, tungsten lamp illumination was used. Ultraviolet spectral changes were measured with a Perkin-Elmer model 552A spectrophotometer. For GC-MS analysis, a Hewlett-Packard 5985A instrument was used with a fused silica capillary column coated with a bonded nonpolar polymethyl silane phase introduced directly into the electron Impact ionization source. Compounds were tentatively identified by comparison to published spectra and confirmed where possible with authentic standard materials. [Pg.209]

Lipid Composition. After the behavior experiments, the rats were killed by decapitation. Tissue samples including brain and retina were removed and stored at -80°C. The total lipid extracts of tissues were prepared according to the method of Folch et al. (39). Butylated hydroxytoluene (300 qg/sample) was added in methanol to each sample to minimize lipid oxidation. The total lipid extracts were trans-methylated with 14% BFj/methanol at 100°C for 60 min by a modification (40) of the method of Morrison and Smith (41). Fatty acid methyl esters were then analyzed on a Hewlett-Packard 5890 gas chromatograph (Hewlett-Packard, Palo Alto, CA) equipped with a flame ionization detector and fused silica capillary column (DB-FFAP, 30 m X 0.25 mm x 0.25 m, J W, Folsom, CA) with carrier gas (hydrogen) at a linear velocity of 50 cm/s. Injector and detector temperature were set to 250°C and oven temperature program was as follows 130 to 175°C at4°C/min, 175 to 210°C at l°C/min, and then to 245 at 30°C/min, with a final... [Pg.133]

More than 20 ammo acids can be analyzed by this procedure in less than 20 min on a fused silica capillary column with ECD. Baseline separations of all amino acid derivatives with fentomole sensitivity are routine. The excellent stability of the derivatives also means that large numbers of samples can be prepared and analyzed overnight using a GC equipped with an automatic sampler... [Pg.42]

Wirth et al. [22] prepared a silica colloidal crystal-packed fused-silica capillary column, and 2 cm-long of which was mounted onto a PDMS chip for evaluation of efficiency of capillary electrochromatography. Three fluorophore-labeled proteins, ribonuclease A, cytochrome C, and lysozyme, were well separated over a distance of 1 cm by isocratic electromigration, using acetonitrile/water (40/60) with 0.1 % formic acid. The plate height for lysozyme was... [Pg.1898]

Figure 6 A typical gas-liquid chromatogram of total bovine milk FAME prepared by NaOCHsfmethanol (10 min at SO C) followed by HCI/methanol (10 min at 80°C), and separated on a 100 m fused silica capillary column (SP-2560) Supelco Inc., Bellefonte, PA). I, iso a, anteiso numbers 1-20 are arbitrary consecutive numbering of all peaks in the region between 18 0 and 18 2o6 using this column. (22 6/>3) is not present in these milk samples but the position at which it should emerge in the chromatogram is indicated. Insert the methyl eicosanoate (20 0) to methyl arachidonate (20 4/>6) region of the GLC of total bovine fatty acid methyl esters prepared by using conventional catalysts. Reproduced with permission from Kramer JKG, Fellner V, Dugan MER, Sauer FD, Mossoba MM, and Yurawecz MP (1997) Lipids 32 1219-1228. Figure 6 A typical gas-liquid chromatogram of total bovine milk FAME prepared by NaOCHsfmethanol (10 min at SO C) followed by HCI/methanol (10 min at 80°C), and separated on a 100 m fused silica capillary column (SP-2560) Supelco Inc., Bellefonte, PA). I, iso a, anteiso numbers 1-20 are arbitrary consecutive numbering of all peaks in the region between 18 0 and 18 2o6 using this column. (22 6/>3) is not present in these milk samples but the position at which it should emerge in the chromatogram is indicated. Insert the methyl eicosanoate (20 0) to methyl arachidonate (20 4/>6) region of the GLC of total bovine fatty acid methyl esters prepared by using conventional catalysts. Reproduced with permission from Kramer JKG, Fellner V, Dugan MER, Sauer FD, Mossoba MM, and Yurawecz MP (1997) Lipids 32 1219-1228.
The catalytic activity of the prepared catalysts for methane combustion was tested in a flow reactor unit. Bottled methane (99.995 % purity from AGA, Sweden) and air were fed to the system using mass flow controllers, giving a methane concentration of 2 vol%. The space velocity in all experiments was 50,000 h". The catalysts were placed in a vertical tubular Inconel reactor situated in a tubular furnace. The exiting gases were analyzed by gas chromatography using a Packard model 427 GC, equiped with a Poraplot Q fused silica capillary column and a thermal conductivity detector. The temperature in the furnace was controlled to give a linear temperature ramp of 2 °C/min in all experiments. Hence, the conversion of methane to carbon dioxide and water was determined as a function of the gas inlet temperature. [Pg.89]

Preparation of high efficiency fused-silica capillary columns coated with graphitized carbon black impregnated with liquid phases was proposed by Bruner and co-workers [23, 24]. This method is a modification of that described by Xu and Vermeulen [25] (free release static coating) for the preparation of glass capillary columns. [Pg.188]


See other pages where Fused-silica capillary columns preparation is mentioned: [Pg.40]    [Pg.603]    [Pg.669]    [Pg.690]    [Pg.250]    [Pg.182]    [Pg.93]    [Pg.407]    [Pg.410]    [Pg.411]    [Pg.595]    [Pg.194]    [Pg.465]    [Pg.334]    [Pg.79]    [Pg.310]    [Pg.418]    [Pg.779]    [Pg.170]    [Pg.224]    [Pg.516]    [Pg.1533]    [Pg.220]    [Pg.261]    [Pg.630]    [Pg.356]    [Pg.112]    [Pg.151]    [Pg.394]    [Pg.671]    [Pg.299]    [Pg.300]    [Pg.2514]    [Pg.27]   
See also in sourсe #XX -- [ Pg.121 , Pg.122 , Pg.123 , Pg.124 , Pg.125 , Pg.126 , Pg.127 , Pg.128 , Pg.129 ]

See also in sourсe #XX -- [ Pg.110 , Pg.111 , Pg.112 , Pg.113 , Pg.114 , Pg.115 , Pg.116 , Pg.117 , Pg.118 , Pg.119 , Pg.120 , Pg.121 ]




SEARCH



Capillary column columns)

Capillary column preparation

Capillary columns

Column preparation

Column preparative

Fused silica

Fused silica capillary columns

Fused silica columns

Fused-silica capillary

Preparation of Fused-Silica Capillary Columns

Preparative capillary

Silica capillary columns

Silica columns

© 2024 chempedia.info