The chromatogram can finally be used as the series of bands or zones of components or the components can be eluted successively and then detected by various means (e.g. thermal conductivity, flame ionization, electron capture detectors, or the bands can be examined chemically). If the detection is non-destructive, preparative scale chromatography can separate measurable and useful quantities of components. The final detection stage can be coupled to a mass spectrometer (GCMS) and to a computer for final identification. [Pg.97]

Some techniques have been described that are based on the concept of flame ionization used in gas chromatography. The results are generally unsatisfactory because it is necessary to evaporate the solvent prior to introducing the mixture into the detector. [Pg.27]

Environmental Analysis One of the most important environmental applications of gas chromatography is for the analysis of numerous organic pollutants in air, water, and wastewater. The analysis of volatile organics in drinking water, for example, is accomplished by a purge and trap, followed by their separation on a capillary column with a nonpolar stationary phase. A flame ionization, electron capture, or... [Pg.571]

Despite their importance, gas chromatography and liquid chromatography cannot be used to separate and analyze all types of samples. Gas chromatography, particularly when using capillary columns, provides for rapid separations with excellent resolution. Its application, however, is limited to volatile analytes or those analytes that can be made volatile by a suitable derivatization. Liquid chromatography can be used to separate a wider array of solutes however, the most commonly used detectors (UV, fluorescence, and electrochemical) do not respond as universally as the flame ionization detector commonly used in gas chromatography. [Pg.596]

These factors make it necessary to reduce the amount of solvent vapor entering the flame to as low a level as possible and to make any droplets or particulates entering the flame as small and of as uniform a droplet size as possible. Desolvation chambers are designed to optimize these factors so as to maintain a near-constant efficiency of ionization and to flatten out fluctuations in droplet size from the nebulizer. Droplets of less than 10 pm in diameter are preferred. For flow rates of less than about 10 pl/min issuing from micro- or nanobore liquid chromatography columns, a desolvation chamber is unlikely to be needed. [Pg.107]

Reference methods for criteria (19) and hazardous (20) poUutants estabHshed by the US EPA include sulfur dioxide [7446-09-5] by the West-Gaeke method carbon monoxide [630-08-0] by nondispersive infrared analysis ozone [10028-15-6] and nitrogen dioxide [10102-44-0] by chemiluminescence (qv) and hydrocarbons by gas chromatography coupled with flame-ionization detection. Gas chromatography coupled with a suitable detector can also be used to measure ambient concentrations of vinyl chloride monomer [75-01-4], halogenated hydrocarbons and aromatics, and polyacrylonitrile [25014-41-9] (21-22) (see Chromatography Trace and residue analysis). [Pg.384]

Fig. 3. (a) Flame ionization detector (fid) response to an extract of commercially processed Valencia orange juice, (b) Gas chromatography—olfactometry (geo) chromatogram of the same extract. The abscissa in both chromatograms is a normal paraffin retention index scale ranging between hexane and octadecane (Kovats index). Dilution value in the geo is the -fold that the extract had to be diluted until odor was no longer detectable at each index. [Pg.6]

Analytical Techniques. Sorbic acid and potassium sorbate are assayed titrimetricaHy (51). The quantitative analysis of sorbic acid in food or beverages, which may require solvent extraction or steam distillation (52,53), employs various techniques. The two classical methods are both spectrophotometric (54—56). In the ultraviolet method, the prepared sample is acidified and the sorbic acid is measured at 250 260 nm. In the colorimetric method, the sorbic acid in the prepared sample is oxidized and then reacts with thiobarbituric acid the complex is measured at - 530 nm. Chromatographic techniques are also used for the analysis of sorbic acid. High pressure Hquid chromatography with ultraviolet detection is used to separate and quantify sorbic acid from other ultraviolet-absorbing species (57—59). Sorbic acid in food extracts is deterrnined by gas chromatography with flame ionization detection (60—62). [Pg.284]

Conversion to acetates, trifluoroacetates (178), butyl boronates (179) trimethylsilyl derivatives, or cycHc acetals offers a means both for identifying individual compounds and for separating mixtures of polyols, chiefly by gas—Hquid chromatography (glc). Thus, sorbitol in bakery products is converted to the hexaacetate, separated, and determined by glc using a flame ionisation detector (180) aqueous solutions of sorbitol and mannitol are similarly separated and determined (181). Sorbitol may be identified by formation of its monobensylidene derivative (182) and mannitol by conversion to its hexaacetate (183). [Pg.52]

Gas Chromatography. Gas chromatography is a technique utili2ed for separating volatile substances (or those that can be made volatile) between two phases, one of which is a gas. Purge-and-trap methods are frequently used for trace analysis. Various detectors have been employed in trace analysis, the most commonly used being flame ioni2ation and electron capture detectors. [Pg.244]

Gas Chromatography Analysis. From a sensitivity standpoint, a comparable technique is a gas chromatographic (gc) technique using flame ioni2ation detection. This method has been used to quantify the trimethylsilyl ester derivative of biotin in agricultural premixes and pharmaceutical injectable preparations at detection limits of approximately 0.3 pg (94,95). [Pg.33]

The most widely used method of analysis for methyl chloride is gas chromatography. A capillary column medium that does a very good job in separating most chlorinated hydrocarbons is methyl siUcone or methyl (5% phenyl) siUcone. The detector of choice is a flame ionisation detector. Typical molar response factors for the chlorinated methanes are methyl chloride, 2.05 methylene chloride, 2.2 chloroform, 2.8 carbon tetrachloride, 3.1, where methane is defined as having a molar response factor of 2.00. Most two-carbon chlorinated hydrocarbons have a molar response factor of about 1.0 on the same basis. [Pg.516]

The detection and determination of traces of cobalt is of concern in such diverse areas as soflds, plants, fertilizers (qv), stainless and other steels for nuclear energy equipment (see Steel), high purity fissile materials (U, Th), refractory metals (Ta, Nb, Mo, and W), and semiconductors (qv). Useful techniques are spectrophotometry, polarography, emission spectrography, flame photometry, x-ray fluorescence, activation analysis, tracers, and mass spectrography, chromatography, and ion exchange (19) (see Analytical TffiTHODS Spectroscopy, optical Trace and residue analysis). [Pg.371]

For selective estimation of phenols pollution of environment such chromatographic methods as gas chromatography with flame-ionization detector (ISO method 8165) and high performance liquid chromatography with UV-detector (EPA method 625) is recommended. For determination of phenol, cresols, chlorophenols in environmental samples application of HPLC with amperometric detector is perspective. Phenols and chlorophenols can be easy oxidized and determined with high sensitivity on carbon-glass electrode. [Pg.129]

Epichlorhydrin (ECH) detection starts with detecting epoxide cycle using hydrochloric acid in combination with sodium chloride the reaction product - 1,3-dichlorhydrin - is extracted in diethyl ether and concentrated by removing the latter. Gas-liquid chromatography with a flame-ionization detector is used to detect glycerin 1,3-dichlorhydrin. The sensitivity of the method is 0.01 mg/dm. ... [Pg.389]

Historically, measurements have classified ambient hydrocarbons in two classes methane (CH4) and all other nonmethane volatile organic compounds (NMVOCs). Analyzing hydrocarbons in the atmosphere involves a three-step process collection, separation, and quantification. Collection involves obtaining an aliquot of air, e.g., with an evacuated canister. The principal separation process is gas chromatography (GC), and the principal quantification technique is wdth a calibrated flame ionization detector (FID). Mass spectroscopy (MS) is used along with GC to identify individual hydrocarbon compounds. [Pg.202]

By using a flame ionization detector (FID), most compounds having a bond of carbon and hydrogen can be measured. This detector was originally developed for gas chromatography and employs a sensitive electrometer that measures the change in ion intensity resulting from the combustion of air... [Pg.1297]

Figure 10.4 Schematic representation of the multidimensional GC-IRMS system developed by Nitz et al. (27) PRl and PR2, pressure regulators SV1-SV4, solenoid valves NV— and NV-I-, needle valves FID1-FID3, flame-ionization detectors. Reprinted from Journal of High Resolution Chromatography, 15, S. Nitz et al, Multidimensional gas cliro-matography-isotope ratio mass specti ometiy, (MDGC-IRMS). Pait A system description and teclinical requirements , pp. 387-391, 1992, with permission from Wiley-VCFI. Figure 10.4 Schematic representation of the multidimensional GC-IRMS system developed by Nitz et al. (27) PRl and PR2, pressure regulators SV1-SV4, solenoid valves NV— and NV-I-, needle valves FID1-FID3, flame-ionization detectors. Reprinted from Journal of High Resolution Chromatography, 15, S. Nitz et al, Multidimensional gas cliro-matography-isotope ratio mass specti ometiy, (MDGC-IRMS). Pait A system description and teclinical requirements , pp. 387-391, 1992, with permission from Wiley-VCFI.
An on-line supercritical fluid chromatography-capillary gas chromatography (SFC-GC) technique has been demonstrated for the direct transfer of SFC fractions from a packed column SFC system to a GC system. This technique has been applied in the analysis of industrial samples such as aviation fuel (24). This type of coupled technique is sometimes more advantageous than the traditional LC-GC coupled technique since SFC is compatible with GC, because most supercritical fluids decompress into gases at GC conditions and are not detected by flame-ionization detection. The use of solvent evaporation techniques are not necessary. SFC, in the same way as LC, can be used to preseparate a sample into classes of compounds where the individual components can then be analyzed and quantified by GC. The supercritical fluid sample effluent is decompressed through a restrictor directly into a capillary GC injection port. In addition, this technique allows selective or multi-step heart-cutting of various sample peaks as they elute from the supercritical fluid... [Pg.325]

Figure 12.20 SFC-GC analysis of a sample of aviation fuel (a) SFC separation into two peaks (b and c) coixesponding GC ttaces of the respective peaks (flame-ionization detection used throughout). Reprinted from Journal of High Resolution Chromatography, 10, J. M. Levy et ah, On-line multidimensional supercritical fluid chromatography/capillary gas chromatography , pp. 337-341, 1987, with permission from Wiley-VCH. Figure 12.20 SFC-GC analysis of a sample of aviation fuel (a) SFC separation into two peaks (b and c) coixesponding GC ttaces of the respective peaks (flame-ionization detection used throughout). Reprinted from Journal of High Resolution Chromatography, 10, J. M. Levy et ah, On-line multidimensional supercritical fluid chromatography/capillary gas chromatography , pp. 337-341, 1987, with permission from Wiley-VCH.
One example of normal-phase liquid chromatography coupled to gas chromatography is the determination of alkylated, oxygenated and nitrated polycyclic aromatic compounds (PACs) in urban air particulate extracts (97). Since such extracts are very complex, LC-GC is the best possible separation technique. A quartz microfibre filter retains the particulate material and supercritical fluid extraction (SPE) with CO2 and a toluene modifier extracts the organic components from the dust particles. The final extract is then dissolved in -hexane and analysed by NPLC. The transfer at 100 p.1 min of different fractions to the GC system by an on-column interface enabled many PACs to be detected by an ion-trap detector. A flame ionization detector (PID) and a 350 p.1 loop interface was used to quantify the identified compounds. The experimental conditions employed are shown in Table 13.2. [Pg.362]

Detectors. The function of the detector in HPLC is to monitor the mobile phase as it emerges from the column. The detection process in liquid chromatography has presented more problems than in gas chromatography there is, for example no equivalent to the universal flame ionisation detector of gas chromatography for use in liquid chromatography. Suitable detectors can be broadly divided into the following two classes ... [Pg.224]


See other pages where Flame chromatography is mentioned: [Pg.577]    [Pg.609]    [Pg.102]    [Pg.107]    [Pg.253]    [Pg.5]    [Pg.108]    [Pg.298]    [Pg.446]    [Pg.142]    [Pg.250]    [Pg.62]    [Pg.69]    [Pg.108]    [Pg.110]    [Pg.116]    [Pg.183]    [Pg.545]    [Pg.551]    [Pg.551]    [Pg.112]    [Pg.59]    [Pg.238]   