Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Experimental procedure measurements

Other experimental procedures measure the energetics and kinetics of thermal electron reactions in the same manner as the ECD and NIMS. These are designated equilibrium methods. The direct capture magnetron method (MGN) and the individual determination of the individual rate constants k and k- for thermal electron reactions are also equilibrium methods. The latter was first carried out in an electron swarm (ES) for O2, but can be applied to any system to measure thermal electron reactions. These methods differ in how the electron and ion concentrations are generated and measured [6, 7],... [Pg.13]

The experimental results of studies on the degradation of filled polymers are often contradictory. This may be caused not only by differences in the methods of production of the filled polymers, but also by the apparatus and experimental procedures (measurements of temperature, pressure, changes in the mass of samples, analysis of low- and high-molecular-mass products of degradation, etc.). Consequently, the description of the apparatus and methods for studies of the degradation of polymers, especially of filled ones, employed in different laboratories is essential, since it may promote the elimination of contradictions and errors that have been observed in certain investigations. [Pg.153]

Mercury porosimetry is generally regarded as the best method available for the routine determination of pore size in the macropore and upper mesopore range. The apparatus is relatively simple in principle (though not inexpensive) and the experimental procedure is less demanding than gas adsorption measurements, in either time or skill. Perhaps on account of the simplicity of the method there is some temptation to overlook the assumptions, often tacit, that are involved, and also the potential sources of error. [Pg.190]

Following the movement of airborne pollutants requires a natural or artificial tracer (a species specific to the source of the airborne pollutants) that can be experimentally measured at sites distant from the source. Limitations placed on the tracer, therefore, governed the design of the experimental procedure. These limitations included cost, the need to detect small quantities of the tracer, and the absence of the tracer from other natural sources. In addition, aerosols are emitted from high-temperature combustion sources that produce an abundance of very reactive species. The tracer, therefore, had to be both thermally and chemically stable. On the basis of these criteria, rare earth isotopes, such as those of Nd, were selected as tracers. The choice of tracer, in turn, dictated the analytical method (thermal ionization mass spectrometry, or TIMS) for measuring the isotopic abundances of... [Pg.7]

The experimental procedure and method of treatment of compression-permeability data have been explained by Grace [Chem. Eng. Prog., 49, 303, 427 (1953)], who showed that the values of a measured in such a cell and in a pressure filter were the same, and by Tiller [Filtr Sep., 12, 386 (1975)]. [Pg.1706]

To obtain the corrosion current from Rp, values for the anodic and cathodic slopes must be known or estimated. ASTM G59 provides an experimental procedure for measuring Rp. A discussion or the factors which may lead to errors in the values for Rp, and cases where Rp technique cannot be used, are covered by Mansfeld in Polarization Resistance Measurements—Today s Status, Electrochemical Techniques for Corrosion Engineers (NACE International, 1992). [Pg.2441]

With correct experimental procedure TDS is straightforward to use and has been applied extensively in basic experiments concerned with the nature of reactions between pure gases and clean solid surfaces. Most of these applications have been catalysis-related (i. e. performed on surfaces acting as models for catalysts) and TDS has always been used with other techniques, e.g. UPS, ELS, AES, and LEED. To a certain extent it is quantifiable, in that the area under a desorption peak is proportional to the number of ions of that species desorbed in that temperature range, but measurement of the area is not always easy if several processes overlap. [Pg.178]

The SFA, originally developed by Tabor and Winterton [56], and later modified by Israelachvili and coworkers [57,58], is ideally suited for measuring molecular level adhesion and deformations. The SFA, shown schematically in Fig. 8i,ii, has been used extensively to measure forces between a variety of surfaces. The SFA combines a Hookian mechanism for measuring force with an interferometer to measure the distance between surfaces. The experimental surfaces are in the form of thin transparent films, and are mounted on cylindrical glass lenses in the SFA using an appropriate adhesive. SFA has been traditionally employed to measure forces between modified mica surfaces. (For a summary of these measurements, see refs. [59,60].) In recent years, several researchers have developed techniques to measure forces between glassy and semicrystalline polymer films, [61-63] silica [64], and silver surfaees [65,66]. The details on the SFA experimental procedure, and the summary of the SFA measurements may be obtained elsewhere (see refs. [57,58], for example.). [Pg.95]

The study of acid-base interaction is an important branch of interfacial science. These interactions are widely exploited in several practical applications such as adhesion and adsorption processes. Most of the current studies in this area are based on calorimetric studies or wetting measurements or peel test measurements. While these studies have been instrumental in the understanding of these interfacial interactions, to a certain extent the interpretation of the results of these studies has been largely empirical. The recent advances in the theory and experiments of contact mechanics could be potentially employed to better understand and measure the molecular level acid-base interactions. One of the following two experimental procedures could be utilized (1) Polymers with different levels of acidic and basic chemical constitution can be coated on to elastomeric caps, as described in Section 4.2.1, and the adhesion between these layers can be measured using the JKR technique and Eqs. 11 or 30 as appropriate. For example, poly(p-amino styrene) and poly(p-hydroxy carbonyl styrene) can be coated on to PDMS-ox, and be used as acidic and basic surfaces, respectively, to study the acid-base interactions. (2) Another approach is to graft acidic or basic macromers onto a weakly crosslinked polyisoprene or polybutadiene elastomeric networks, and use these elastomeric networks in the JKR studies as described in Section 4.2.1. [Pg.134]

Additional suggested resources for the reader include introductory articles on scanning probe techniques for materials properties measurement [82,83J. A comprehensive manual describing various surface preparation techniques, experimental procedures and instrumentation is also a good resource [84J, although the more recent modulation based techniques are not covered. Key textbooks include Johnson s on contact mechanics [51J and Israelachvili s on surface forces [18J, as well as a treatment of JKR/DMT issues by Maugis [85J. [Pg.206]

As described in Section 6.2.1., British Gas performed full-scale tests with LPG BLEVEs similar to those conducted by BASF. The experimenters measured very low overpressures firom the evaporating liquid, followed by a shock that was probably the so-called second shock, and by the pressure wave from the vapor cloud explosion (see Figure 6.6). The pressure wave firom the vapor cloud explosion probably resulted from experimental procedures involving ignition of the release. The liquid was below the superheat limit temperature at time of burst. [Pg.200]

Discussion. The turbidity of a dilute barium sulphate suspension is difficult to reproduce it is therefore essential to adhere rigidly to the experimental procedure detailed below. The velocity of the precipitation, as well as the concentration of the reactants, must be controlled by adding (after all the other components are present) pure solid barium chloride of definite grain size. The rate of solution of the barium chloride controls the velocity of the reaction. Sodium chloride and hydrochloric acid are added before the precipitation in order to inhibit the growth of microcrystals of barium sulphate the optimum pH is maintained and minimises the effect of variable amounts of other electrolytes present in the sample upon the size of the suspended barium sulphate particles. A glycerol-ethanol solution helps to stabilise the turbidity. The reaction vessel is shaken gently in order to obtain a uniform particle size each vessel should be shaken at the same rate and the same number of times. The unknown must be treated exactly like the standard solution. The interval between the time of precipitation and measurement must be kept constant. [Pg.729]

A further procedure will be described only for m-xylene, for which we obtained the following values of the constants fci = 173.7, fc2 = 84.2 mole hr-1 kg-1 atm-1 K — 20.6, Ko = 25.8 atm-1. The conclusions drawn from the study of consecutive hydrodemethylation were similar for all the three xylenes studied (100). The influencing of individual reactions by products and by the intermediate product was determined experimentally, by measuring their effect on the reaction of m-xylene and toluene. The adsorption coefficients, which express this effect, are listed in Table III. [Pg.29]

FIGURE 6 Distribution of [ HlBCNU-associated radioactivity time in rabbit brain. The distribution of radioactivity was measured using quantitative autoradiography techniques following implantation of discs described for Fig. 5 into the brains of rabbits. Details of the experimental procedure are described in the text. [Pg.53]

Much of our present day knowledge of sweetness intensity, both at the threshold level, where taste begins, and above the threshold level, derives from the application of psychophysical techniques. It is now evident that the psychophysical procedure used measure separate aspects of sweetness perception. Hedonic responses cannot be predicted from intensity of discrimination data, and vice versa. The taste-panel evaluation of sweetness is of fundamental importance in the development of worthwhile structure-taste relationships. Therefore, it is vital that the appropriate psychophysical method and experimental procedure be adopted for a particular objective of investigation. Otherwise, false conclusions, or improper inferences, or both, result. This situation results from the failure to recognize that individual tests measure separate parameters of sensory behavior. It is not uncommon that the advocates of a specific method or procedure seldom... [Pg.349]

Catalytic measurements were carried out in a stirred-bed reactor of stainless steel. The details of the reactor and experimental procedures have been described elsewhere [4]. [Pg.326]

The absorption rates of CO2 were measured in such non-aqueous solvents as toluene, NMP, and DMSO with GMA concentration ranging Ifom 0.5 to 3 kmol/m in a semi-batch flat-stirred agitated vessel constructed of pyrex glass of 0.075 m inside diameter and of 0.13 m in height. The apparatus and the experimental procedure are the same as those described by... [Pg.347]

The kinetics of the various reactions have been explored in detail using large-volume chambers that can be used to simulate reactions in the troposphere. They have frequently used hydroxyl radicals formed by photolysis of methyl (or ethyl) nitrite, with the addition of NO to inhibit photolysis of NO2. This would result in the formation of 0( P) atoms, and subsequent reaction with Oj would produce ozone, and hence NO3 radicals from NOj. Nitrate radicals are produced by the thermal decomposition of NjOj, and in experiments with O3, a scavenger for hydroxyl radicals is added. Details of the different experimental procedures for the measurement of absolute and relative rates have been summarized, and attention drawn to the often considerable spread of values for experiments carried out at room temperature (-298 K) (Atkinson 1986). It should be emphasized that in the real troposphere, both the rates—and possibly the products—of transformation will be determined by seasonal differences both in temperature and the intensity of solar radiation. These are determined both by latitude and altitude. [Pg.16]

The fluid leak-off during hydraulic fracturing can be modeled, calculated, and measured experimentally. Procedures for converting laboratory data to an estimate of the leak-off under field conditions have been given in the literature [1426]. [Pg.237]

Independent reference methods - one organization Two or more independent reference methods, each based on an entirely conceptually different principle of measurement, independent in theory and experimental procedure, applied in replicate, within a single organization, of the highest reputational quality, by two or more expert analysts, working independently. The methods used can, naturally, include definitive methods, and the results should be corroborated by a third or additional, independently different, accurately characterized, well established, thoroughly validated, definitive, reference, or other methods. [Pg.53]

The results of activation analysis are subject to well known and common analytical sources of uncertainty, as well as method specific uncertainties, e.g. summarized by Greenberg (1997), and also in Section 2.2. In order for INAA experiments to measure differences in induced activity, i.e. differences due to heterogeneity in the amount of analyte in a given test portion, the experimental procedure is designed to allow only the following uncertainties to be part of the result ... [Pg.135]

As usually viewed by the reference material producers, a fundamental philosophy of certification rests on the concept of independent methodology, which is the application of theoretically and experimentally different measurement techniques and procedures to generate concordant results leading to one reliable assigned value for the property. Such assigned values are thus method-independent. Extractable concentrations are generated by specific procedures and are thus method-dependent, an idea that has to be rationalized with the fundamental method-independent concept in reference material certification work. [Pg.286]

The closeness of agreement between independent test results obtained by applying the experimental procedure under stipulated conditions. The smaller the random part of the experimental errors which affect the results, the more precise the procedure. A measure of precision (or imprecision) is the standard deviation. [Pg.79]


See other pages where Experimental procedure measurements is mentioned: [Pg.1510]    [Pg.81]    [Pg.180]    [Pg.127]    [Pg.92]    [Pg.1048]    [Pg.682]    [Pg.97]    [Pg.390]    [Pg.149]    [Pg.504]    [Pg.267]    [Pg.128]    [Pg.277]    [Pg.24]    [Pg.190]    [Pg.340]    [Pg.502]    [Pg.74]    [Pg.334]    [Pg.323]    [Pg.29]   
See also in sourсe #XX -- [ Pg.97 ]




SEARCH



Experimental measurement

Experimental procedures

© 2024 chempedia.info