Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chamber volume

Performance in Colter. The modified monomer should perform well ia commercial deposition equipment. Performance considerations iaclude the growth rate of the coating, the uniformity of thickness of the coating over the chamber volume, and the efficiency with which the dimer is converted to useful coatings on the substrates. [Pg.429]

Computer Models, The actual residence time for waste destmction can be quite different from the superficial value calculated by dividing the chamber volume by the volumetric flow rate. The large activation energies for chemical reaction, and the sensitivity of reaction rates to oxidant concentration, mean that the presence of cold spots or oxidant deficient zones render such subvolumes ineffective. Poor flow patterns, ie, dead zones and bypassing, can also contribute to loss of effective volume. The tools of computational fluid dynamics (qv) are useful in assessing the extent to which the actual profiles of velocity, temperature, and oxidant concentration deviate from the ideal (40). [Pg.57]

In equation (4.30), the rate of change of chamber volume is due to the piston movement, i.e. dVldt. The rate of change of oil volume is due to compressibility effects, i.e. ... [Pg.77]

The introduction of water, or air to a lesser extent, from the backside of flexible membranes reduces chamber volume and squeezes the cake yielding a further lowering of the moisture content. The filter press may be arranged as a mixed pack of flush and membrane plates, full flush or full membrane pack depending on the application. [Pg.188]

In an effort to determine the processes responsible for this type of behavior, Akiba and Tanno (A3), Sehgal and Strand (S2), and Beckstead (B6) have studied the coupling between the dynamics of the combustion process and the dynamic ballistics of the combustion chamber as described by Eq. (7). Each of these investigators has postulated admittedly simplified but slightly different combustion models to couple with the transient ballistic equations. Each has examined the combined equations for regions of instability. The results of these studies suggest a correlation between the L of the motor (the ratio of combustion-chamber volume to nozzle throat area) and the frequency of the oscillations. [Pg.57]

The compounds were mixed in three steps The first two steps were done in an internal mixer with a mixing chamber volume of 390 mL. The mixing procedures employed in the first two steps are indicated in Table 29.2. The starting temperamre was 50°C and the cooling water was kept at a constant temperature of 50°C. The rotor speed was 100 rpm and the fill factor 66%. After every mixing step the compound was sheeted out on a 100-mL two-roll mill. The third mixing step was done on the same two-roll mill. The accelerators and sulfur were added during this step. [Pg.806]

The anticircular development chamber contains many of the features. found in the D-chamber. The plate is developed horizontally, the chamber volume is small, and the vapor phase can be controlled by external means [111]. An outer circle is cut fron... [Pg.364]

The discharge compartment is mechanically separated from the ionization chamber by an optically transparent window made of setal fluoride. The effluent from the column passes through the themostated ionization chamber and between two electrodes, positioned at opposite ends of the chamber. Detectors with ionization chamber volumes of 40 and 175 microliters are available for use with capillary columns and of 175 and 225 microliters for packed columns. An electric field is applied between the electrodes to collect the ions formed (or electrons, if preferred) and the current amplified by a precision electrometer. It has been shown that careful thermostating of the detector is required to reduce baseline drift [107,109]. [Pg.654]

The experimental set-up for cellular oxygen measurements (p02) consists of following components p02 measuring micro chamber (volume 0.6 microliter), polarographic microelectrode, water-bath for constant temperature, chemical microsensor connected to a strip-chart recorder and gas calibration unit. [Pg.505]

V is the chamber volume, L is the light beam path length, A is the sample area, and T is the transmittance. [Pg.296]

The amount of water desorbed can be calculated by the pressure rise after the valve between the chamber and condenser has been closed, divided by the time of closure and the chamber volume (see Section 1.2.3). [Pg.77]

A chamber volume and the amount of ice to be sublimed during MD must satisfy the following conditions ... [Pg.89]

The concentration of the test atmosphere must be reasonably uniform throughout the chamber and should increase and decrease at a rate close to theoretical at the start or end of the exposure. Silver (1946) showed that the time taken for a chamber to reach a point of equilibrium was proportional to the flow rate of atmosphere passing through the chamber and the chamber volume. From this, the concentration-time relationship dining the run-up and run-down phase could be expressed by the equation... [Pg.352]


See other pages where Chamber volume is mentioned: [Pg.382]    [Pg.513]    [Pg.252]    [Pg.1234]    [Pg.1648]    [Pg.467]    [Pg.57]    [Pg.125]    [Pg.77]    [Pg.393]    [Pg.394]    [Pg.415]    [Pg.560]    [Pg.410]    [Pg.186]    [Pg.399]    [Pg.299]    [Pg.129]    [Pg.364]    [Pg.364]    [Pg.361]    [Pg.186]    [Pg.193]    [Pg.46]    [Pg.352]    [Pg.352]    [Pg.57]    [Pg.88]    [Pg.89]    [Pg.95]    [Pg.95]    [Pg.176]    [Pg.173]    [Pg.174]    [Pg.50]    [Pg.352]    [Pg.227]    [Pg.255]   
See also in sourсe #XX -- [ Pg.515 , Pg.523 ]




SEARCH



Bubble chamber, volume

Burn rate volume chamber

Chamber free volume

Mixing chamber volumes

Volume ventricular chambers

Volume, constant, combustion chamber

© 2024 chempedia.info