Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Emission technique

These new regulations will contribute to the development of the acoustic emission technique. [Pg.56]

Determination of contact Fatique Properties Using Acoustic Emission Technique. [Pg.59]

At contact fatigue tests of different steel and cast iron types was used the acoustic emission technique. Processed records from the AE analyser show importance of acoustic response of tested surface continuous sensing. In graphs are obvious characteristic types of summation curves, or may be from significant changes of AE signal course identified even phases of the wear process. [Pg.66]

However acoustic emission technique utilisation for contact fiitigue observation requires solution of numerous problems, among which belong e.g. ... [Pg.66]

YOSHIOKA,T.- MINORU,T. Clarification of Rolling Contact Fatigue Initiation using Acoustic Emission Technique. Lubrication Engineering, Vol.51, No.l, 1995, p.41-44. [Pg.66]

YOSHIOKA,T. Detection of Rolling Contact Sub-Surftice Fatigue Cracks Using Acoustic Emission Technique. Lubrication Engineering, Vol.49, No.4, 1993, p.303-308. [Pg.66]

The research activity here presented has been carried out at the N.D.T. laboratory of l.S.P.E.S.L. (National Institute for Occupational Safety and Prevention) and it is aimed at the set up of the Stress Pattern Analysis by Measuring Thermal Emission technique [I] applied to pressure vessels. Basically, the SPATE system detects the infrared flux emitted from points resulting from the minute temperature changes in a cyclically stressed structure or component. [Pg.408]

The determination of cesium in minerals can be accompHshed by x-ray fluorescence spectrometry or for low ranges associated with geochemical exploration, by atomic absorption, using comparative standards. For low levels of cesium in medical research, the proton induced x-ray emission technique has been developed (40). [Pg.377]

Visual identification prior to failure is difficult due to the typical tightness of stress-corrosion cracks. A low-power hand lens will greatly aid determination. Crack enhancement may be achieved through the use of dye penetrants. Severe cracking may be detectable using ultrasonic, radiographic, or acoustic emission techniques. [Pg.208]

Cause, R.L., A nonconiacting scanning photoelectron emission technique for bonding surfaces cleanliness inspection. NASA Technical Memorandum NASA TM-100361, 1989. Schirato, R.C., Polichar, R.M. and Shreve, D.C., In Proc JANNAF Nondestructive Evaluation Subcommittee Meeting. Chemical Propulsion Information Agency, Columbia, MD, 1992. [Pg.1008]

Detectors based on established optical absorption and emission techniques,... [Pg.200]

N) J.S. Ziomek, Application of Hollow, Cathode and Microwave-Simulated Emission Techniques , Rept No IITRI-U6042-3, Contract DA-44-009-AMC-1S76(T), IIT Res Inst, Chicago (1968)... [Pg.787]

The case of water is particularly convenient because the required high Ka states may be detected in the solar absorption spectrum. However, it is difficult to observe the necessary high vibrational angular momentum states in molecules, which can only be probed by dispersed fluorescence or stimulated emission techniques. On the other hand, it is now possible to perform converged variational calculations on accurate potential energy surfaces, from which one could hope to verify the quantum monodromy and assess the extent to which it is disturbed by perturbations with other modes. Examples of such computed monodromy are seen for H2O in Fig. 2 and LiCN in Fig. 12. [Pg.89]

Various forms of off- and on-line AES/AAS can achieve element specific detection in IC. The majority of atomic emission techniques for detection in IC are based on ICP. In the field of speciation analysis both IC-ICP-AES and IC-ICP-MS play an important role. Besides the availability of the ICP ion source for elemental MS analysis, structural information can be provided by interfaces and ion sources like particle beam or electrospray. [Pg.272]

In AFS, the analyte is introduced into an atomiser (flame, plasma, glow discharge, furnace) and excited by monochromatic radiation emitted by a primary source. The latter can be a continuous source (xenon lamp) or a line source (HCL, EDL, or tuned laser). Subsequently, the fluorescence radiation is measured. In the past, AFS has been used for elemental analysis. It has better sensitivity than many atomic absorption techniques, and offers a substantially longer linear range. However, despite these advantages, it has not gained the widespread usage of atomic absorption or emission techniques. The problem in AFS has been to obtain a... [Pg.624]

UHV techniques are usually classified in terms of the electron/photon method, as is shown in Table 2.3 which lists the common electron bombardment and emission techniques that have been employed in electrochemical studies. A detailed description of UHV surface analysis techniques is beyond the scope of this book there are many excellent reference texts that can be consulted for this purpose (see further reading list). It is sufficient to note that methods involving electron bombardment or emission are inherently surface-sensitive as a result of the low pathlength, or escape depth, of electrons in condensed media. In addition, Table 2.3 briefly describes the type of information each method provides. [Pg.225]

The techniques available to achieve molecular structure determinations are limited. They include structural analysis with diffraction techniques—such as electron, neutron, and x-ray diffraction—and various absorption and emission techniques of electromagnetic radiation—such as microwave spectroscopy and nuclear magnetic resonance (NMR). For molecules with unpaired spins a companion technique of electron spin resonance spectroscopy (ESR) is highly informative. [Pg.57]

The basic instrumentation used for spectrometric measurements has already been described in the previous chapter (p. 277). Methods of excitation, monochromators and detectors used in atomic emission and absorption techniques are included in Table 8.1. Sources of radiation physically separated from the sample are required for atomic absorption, atomic fluorescence and X-ray fluorescence spectrometry (cf. molecular absorption spectrometry), whereas in flame photometry, arc/spark and plasma emission techniques, the sample is excited directly by thermal means. Diffraction gratings or prism monochromators are used for dispersion in all the techniques including X-ray fluorescence where a single crystal of appropriate lattice dimensions acts as a grating. Atomic fluorescence spectra are sufficiently simple to allow the use of an interference filter in many instances. Photomultiplier detectors are used in every technique except X-ray fluorescence where proportional counting or scintillation devices are employed. Photographic recording of a complete spectrum facilitates qualitative analysis by optical emission spectrometry, but is now rarely used. [Pg.288]

Flame emission spectrometry is used extensively for the determination of trace metals in solution and in particular the alkali and alkaline earth metals. The most notable applications are the determinations of Na, K, Ca and Mg in body fluids and other biological samples for clinical diagnosis. Simple filter instruments generally provide adequate resolution for this type of analysis. The same elements, together with B, Fe, Cu and Mn, are important constituents of soils and fertilizers and the technique is therefore also useful for the analysis of agricultural materials. Although many other trace metals can be determined in a variety of matrices, there has been a preference for the use of atomic absorption spectrometry because variations in flame temperature are much less critical and spectral interference is negligible. Detection limits for flame emission techniques are comparable to those for atomic absorption, i.e. from < 0.01 to 10 ppm (Table 8.6). Flame emission spectrometry complements atomic absorption spectrometry because it operates most effectively for elements which are easily ionized, whilst atomic absorption methods demand a minimum of ionization (Table 8.7). [Pg.319]


See other pages where Emission technique is mentioned: [Pg.45]    [Pg.59]    [Pg.59]    [Pg.62]    [Pg.62]    [Pg.432]    [Pg.48]    [Pg.395]    [Pg.335]    [Pg.336]    [Pg.338]    [Pg.342]    [Pg.344]    [Pg.346]    [Pg.348]    [Pg.350]    [Pg.352]    [Pg.354]    [Pg.356]    [Pg.358]    [Pg.360]    [Pg.362]    [Pg.364]    [Pg.366]    [Pg.368]    [Pg.643]    [Pg.935]    [Pg.20]    [Pg.338]    [Pg.275]   
See also in sourсe #XX -- [ Pg.57 ]

See also in sourсe #XX -- [ Pg.122 ]




SEARCH



ATOMIC emission spectroscopy 1 Technique

Acoustic emission technique

Analytical techniques atomic absorption/emission spectrometry

Atomic Emission Techniques

Atomic Emission and Inductively Coupled Plasma Techniques

Classification of Techniques Absorption, Emission and Fluorescence

Conventional emission spectroscopy techniques

Emission and consumption data of PET processing techniques

Emission data for the exhaust gas from fettling, using various dedusting techniques

Emission intensity, measurement techniques

Emissions, Control Techniques and Their Effectiveness

Gaseous emissions techniques

Methods in Surface Kinetics Flash Desorption, Field Emission Microscopy, and Ultrahigh Vacuum Techniques Gert Ehrlich

Optical emission spectrographic techniques

Plasma emission spectroscopy hyphenated techniques

Positron emission tomography technique

Rating scheme for emission reduction techniques in PS processes

Some Developments in Field Emission Techniques and their Application

Spectrometric techniques optical emission spectrometry

Split view - VCM emissions related to BAT techniques

Techniques for Reflectance and Emission Measurements

The Emission Technique

© 2024 chempedia.info