Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Electrospray-tandem mass spectrometry

Kasprzyk-Hordern B, Dinsdale RM, Guwy AJ (2008) Multiresidue methods for the analysis of pharmaceuticals, personal care products and illicit drugs in surface water and wastewater by solid-phase extraction and ultra performance liquid chromatography-electrospray tandem mass spectrometry. Anal Bioanal Chem 391(4) 1293-1308... [Pg.225]

Postigo C, Lopez De Alda MJ, Barcelo D (2008) Fully automated determination in the low nanogram per liter level of different classes of drugs of abuse in sewage water by on-line solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry. Anal Chem 80(9) 3123-3134... [Pg.225]

Figure 5.27 Selective detection of lactolated peptides from a tryptic digest of / -lacto-globulins by LC-electrospray-MS-MS, showing (a) the total-ion-cnrrent trace in full-scan mode, and (b) the total-ion-current trace in neutral-loss-scanning mode. Figure from Selective detection of lactolated peptides in hydrolysates by liquid chromatography/ electrospray tandem mass spectrometry , by Molle, D., Morgan, F., BouhaUab, S. and Leonil, J., in Analytical Biochemistry, Volume 259, 152-161, Copyright 1998, Elsevier Science (USA), reproduced with permission from the publisher. Figure 5.27 Selective detection of lactolated peptides from a tryptic digest of / -lacto-globulins by LC-electrospray-MS-MS, showing (a) the total-ion-cnrrent trace in full-scan mode, and (b) the total-ion-current trace in neutral-loss-scanning mode. Figure from Selective detection of lactolated peptides in hydrolysates by liquid chromatography/ electrospray tandem mass spectrometry , by Molle, D., Morgan, F., BouhaUab, S. and Leonil, J., in Analytical Biochemistry, Volume 259, 152-161, Copyright 1998, Elsevier Science (USA), reproduced with permission from the publisher.
Figure 5.62 Product-ion MS-MS spectra of the molecular ions from 8-hydroxy-2 -deoxyguanosine, obtained by (a) positive, and (b) negative ionization. Reprinted by permission of Elsevier Science from Comparison of negative- and positive-ion electrospray tandem mass spectrometry for the liquid chromatography-tandem mass spectrometry analysis of oxidized deoxynucleosides , by Hua, Y., Wainhaus, S. B., Yang, Y., Shen, L., Xiong, Y., Xu, X., Zhang, F. Bolton, J. L. and van Breemen, R. B., Journal of the American Society for Mass Spectrometry, Vol. 12, pp. 80-87, Copyright 2000 by the American Society for Mass Spectrometry. Figure 5.62 Product-ion MS-MS spectra of the molecular ions from 8-hydroxy-2 -deoxyguanosine, obtained by (a) positive, and (b) negative ionization. Reprinted by permission of Elsevier Science from Comparison of negative- and positive-ion electrospray tandem mass spectrometry for the liquid chromatography-tandem mass spectrometry analysis of oxidized deoxynucleosides , by Hua, Y., Wainhaus, S. B., Yang, Y., Shen, L., Xiong, Y., Xu, X., Zhang, F. Bolton, J. L. and van Breemen, R. B., Journal of the American Society for Mass Spectrometry, Vol. 12, pp. 80-87, Copyright 2000 by the American Society for Mass Spectrometry.
Montoro, P. et al., Characterisation by liquid chromatography-electrospray tandem mass spectrometry of anthocyanins in extracts of Myrtus communis L. berries used for the preparation of myrtle liqueur, J. Chromatogr. A, 1112, 232, 2006. [Pg.503]

G.C. Mattem, C.I. Nuessle, D.L. Green, W.M. Leimkuehler, J.D. Philpot, RJ. Ness, and K.S. Billesbach, Accelerated field residue analysis of tebuconazole using Soxtec extraction and HPLC/electrospray tandem mass spectrometry (HPLC/ESI-MS-MS), Presented at the Midwest Regional Meeting of the American Chemical Society, Osage Beach, MO, October 29, 1997. [Pg.1241]

Shahgholi, M. Ohorodnik, S. Callahan, J. H. Fox, A. Trace detection of underiva-tized muramic acid in environmental dust samples by microcolumn liquid chromatography electrospray-tandem mass spectrometry. Anal. Chem. 1997, 69, 1956-1960. [Pg.35]

Black, G. E. Fox, A. Fox, K. Snyder, A. R Smith, R B. Electrospray tandem mass spectrometry for analysis of native muramic acid in whole bacterial cell hydroslysates. Anal. Chem. 1994, 66,4171 4176. [Pg.253]

Prasain, J. K. Ueki, M. Stefanowicz, P. Osada, H. Rapid screening and identification of cytochalasins by electrospray tandem mass spectrometry. J. Mass Spectrom. 2002,37, 283-291. [Pg.254]

Lopez-Sema R, Perez S, Ginebreda A, Petrovic M, Barcelo D (2010) Fully automated determination of 74 pharmaceuticals in environmental and waste waters by online solid phase extraction-liquid chromatography-electrospray-tandem mass spectrometry. Talanta 83(2) 410 124... [Pg.44]

Eichhom P, Lopez O, Barcelo D (2005) Application of liquid chromatography-electrospray-tandem mass spectrometry for the identification and characterisation of linear alkylbenzene sulfonates and sulfophenyl carboxylates in sludge-amended soils. J Chromatogr A 1067 171-179... [Pg.45]

Ducret, A., Van Oostveen, I., Eng, J.K., Yates, J.R., 3rd, Aebersold, R. (1998). High throughput protein characterization by automated reverse-phase chromatography/electrospray tandem mass spectrometry. Protein Sci. 7, 706-719. [Pg.315]

Budzikiewicz, H., Schafer, M., Fernandez, D. U., Matthijs, S. and Cornelis, P. (2007). Characterization of the chromophores of pyoverdins and related siderophores by electrospray tandem mass spectrometry. Biometals 20, 135-44. [Pg.522]

Canezin J, Cailleux A, Turcant A, Le Bouil A, Harry P, Allain P (2001) Determination of LSD and its metabolites in human biological fluids by high-performance liquid chromatography with electrospray tandem mass spectrometry. J Chromatogr B Biomed Sci Appl 765 15-27... [Pg.207]

Kampioti AA, da Cunha ACB, de Alda ML et al (2005) Fully automated multianalyte determination of different classes of pesticides, at picogram per litre levels in water, by online solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry. Anal Bioanal Chem 382 1815-1825... [Pg.274]

RASHED, M.S., BUCKNALL, M.P., LITTLE, D., AWAD, A., JACOB, M., ALAMOUDI, M., ALWATTAR, M., OZAND, P.T., Screening blood spots for inborn errors of metabolism by electrospray tandem mass spectrometry with a microplate batch process and a computer algorithm for automated flagging of abnormal profiles, Clin. Chem., 1997,43,1129-1141. [Pg.79]

Morrison D., Davies, A.E., and Watt, A.P. 2002. An evaluation of a four-channel multiplexed electrospray tandem mass spectrometry for higher throughput quantitative analysis. Anal. Chem. 74 1896. [Pg.243]

Wachs, T. and Henion, J. 2003. A device for automated direct sampling and quantitation from solid-phase sorbent extraction cards by electrospray tandem mass spectrometry. Anal. Chem. 75 1769. [Pg.243]

Ibanez M. et al., 2005. Residue determination of glyphosate, glufosinate and aminomethylphosphonic acid in water and soil samples by hquid chromatography coupled to electrospray tandem mass spectrometry. J Chromatogr A 1081 145. [Pg.295]

Jemal M., Xia Y., and Whigan D.B., 1998. The use of high-flow high performance liquid chromatography coupled with positive and negative ion electrospray tandem mass spectrometry for quantitative bioanalysis via direct injection of the plasma/serum samples. Rapid Commun Mass Spectrom 12 1389. [Pg.295]

Rodriguez-Mozaz S., de Alda M.J.L., and Barcelo D., 2004. Picogram per liter level determination of estrogens in natural waters and waterworks by a fully automated online solid-phase extraction-liquid chromatog-raphy-electrospray tandem mass spectrometry method. Anal Chem 76 6998. [Pg.296]

M. Pelzing and C. NeusiiB. Separation Techniques Hyphenated to Electrospray-Tandem Mass Spectrometry in Proteomics Capillary Electrophoresis versus Nanoliquid Chromatography. Electrophoresis, 26(2005) 2717-2728. [Pg.84]

C. Protein Identification Via Electrospray Tandem Mass Spectrometry. . 13... [Pg.1]

Even though the MALDI peptide mass mapping technique is very powerful, it has limitations. It requires well-separated proteins, is less sensitive than identifications based on electrospray tandem mass spectrometry, can only identify proteins whose complete sequences are available in databases, and does not produce redundant information. [Pg.12]

Fig. 7. Protein identification with electrospray tandem mass spectrometry and a triple quadrupole mass spectrometer. Fragment spectra of several peptides are generated during one investigation. From the fragment spectra short sequence stretches can be read. Together with their mass location in the peptide of the measured mass, they can be used to specifically identify a protein in the database. Because the protein identification depends only on one peptide, several proteins can be identified from one sample. Fig. 7. Protein identification with electrospray tandem mass spectrometry and a triple quadrupole mass spectrometer. Fragment spectra of several peptides are generated during one investigation. From the fragment spectra short sequence stretches can be read. Together with their mass location in the peptide of the measured mass, they can be used to specifically identify a protein in the database. Because the protein identification depends only on one peptide, several proteins can be identified from one sample.
Continuous ion series are often generated when multiply charged peptide ions are fragmented. The problem in de novo sequencing with electrospray tandem mass spectrometry lies in minimizing the error rate of the interpretation. There are two different approaches to this problem ... [Pg.16]

A separation method using RP-HPLC and electrospray-tandem mass spectrometry was developed for the simultaneous determination of Sudan-azo dyes in hot chilli products. The chemical structures of the azo dyes included in the investigation are listed in... [Pg.424]

F. Calbiani, M. Careri, L. Elviri, A. Mangia, L. Pistara and I. Zagnoni, Development and in-house validation of a liquid chromatography-electrospray-tandem mass spectrometry method for the simultaneous determination of Sudan I, Sudan II, Sudan II and Sudan IV in hot chili products. J. ChromatogrA, 1043 (2004) 123-130. [Pg.567]

Rashed, M.S. et al.. Determination of L-pipecolic acid in plasma using chiral liquid chromatography-electrospray tandem mass spectrometry, Clin. Chem., 47, 2124, 2001. [Pg.168]


See other pages where Electrospray-tandem mass spectrometry is mentioned: [Pg.226]    [Pg.12]    [Pg.13]   
See also in sourсe #XX -- [ Pg.224 ]

See also in sourсe #XX -- [ Pg.2242 ]

See also in sourсe #XX -- [ Pg.582 ]




SEARCH



Electrospray tandem

Mass spectrometry electrospray

Mass spectrometry tandem

Spectrometry electrospray

Tandem spectrometry

© 2024 chempedia.info