Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Residue to determine

Consistent with other analytical methods, immunoassays must be validated to ensure that assay results are accurate. Initial validation involves an evaluation of the sensitivity and specificity of the immunoassay, while later validation includes comparison with a reference method. Because a goal of immunoassays is to minimize sample preparation, validation also includes testing the effects of sample matrices and(or) sample cleanup methods on results. The final steps in validation involve testing a limited number of samples containing incurred residues to determine if the method provides reliable data. [Pg.646]

Spark source mass spectrometry is used for the examination of non-volatile inorganic samples and residues to determine elemental composition. An RF spark of about 30 kV is passed between two electrodes, one of which may be the sample itself, causing vaporization and ionization. Powdered samples or residues from ashed organic materials can be formed into an electrode after mixing with pure graphite powder. [Pg.428]

Testing procedure Volatile products of degradation were absorbed in Tenax cartridges and the ethanolic eluate of the Tenax cartridge was analyzed by GC-MS."" The furnace type pyrolyzer was connected to the gas chromatograph, and pyrolysis was conducted under helium. Volatiles were used for the identification of polymer and residue to determine the amount of carbon black. The standard error of determination of carbon black was in the range of 0.2 to 3.4%. [Pg.592]

Drift in a sensor or a combination of bias change and noise inflation would affect both the means and variances of the residuals. To determine which one of these sensor faults has occurred, an additional test is performed. The data for the variable under study is filtered bj using a moving average filter in order to eliminate the effects of process/instrument noise. If the filtered data have a non-stationary mean (changing over time as a... [Pg.211]

Figure 10.89 Linear regression analysis of the calculated second residuals to determine the absorption phase model parameters. Figure 10.89 Linear regression analysis of the calculated second residuals to determine the absorption phase model parameters.
Packer, E., Sternlicht, II., Lode, E. T., and Rabinowitz, J. C. (1975)./. Biol. Chem. 250, 2062. The use of 1 3C Nuclear Magnetic Resonance of Aromatic Amino Acid Residues to Determine the Midpoint Oxidation-Reduction Potential of Each Iron-Sulfur Cluster of Clostridium Acidic-Urici and Clostridium Pasteurianum Ferredoxins. [Pg.421]

By calculating the sum of the squares of the spectral residuals across all the wavelengths, an additional representative value can be generated for each spectrum. The spectral residual is effectively a measure of the amount of each spectrum left over in the secondary or noise vectors. This value is the basis of another type of discrimination method known as SIMCA (Refs. 13, 36). This is similar to performing an F test on the spectral residual to determine outliers in a training set (see Outlier Sample Detection in Chapter 4). In fact, one group combined the PCA-Mahalanobis distance method with SIMCA to provide a biparametric method of discriminant analysis (Ref. 41). In this method, both the Mahalanobis distance and the SIMCA test on the spectral residual had to pass in order for a sample to be classified as a match. [Pg.177]

Consider a chemical engineer who is studying the yield of a chemical process. There are 2 variables of interest reaction time and reaction temperature. Since there is some uncertainty regarding the appropriateness of a linear model, a single unreplicated 2 -factorial experiment was performed with 5 centre point replicates. The results of the experiment are shown in Table 4.9. Based on the provided results, analyse the model using the methods provided in the above discussion to determine the best model for the process. Be certain to analyse the residuals to determine the adequacy of the model Data taken from Montgomery, Applied Statistics and Probability for Engineers, 4th edn.). [Pg.195]


See other pages where Residue to determine is mentioned: [Pg.738]    [Pg.61]    [Pg.440]    [Pg.342]    [Pg.295]    [Pg.123]    [Pg.313]    [Pg.1194]    [Pg.690]    [Pg.90]    [Pg.112]    [Pg.121]    [Pg.356]    [Pg.127]    [Pg.203]   
See also in sourсe #XX -- [ Pg.10 ]




SEARCH



© 2024 chempedia.info