Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Enantiomer application

Chiral derivatization reagents should be 100% pure or of accurately known purity for analytical applications Enantiomers have the same detector response Unsuitable for preparative separations... [Pg.217]

Nafie LA and Freedman TB (1998) Vibrational circular dichroism an incisive tool for stereochemical applications. Enantiomer 3 283-297. [Pg.1232]

Application of the CCM to small sets (n < 6) of enzyme inhibitors revealed correlations between the inhibitory activity and the chirality measure of the inhibitors, calculated by Eq. (26) for the entire structure or for the substructure that interacts with the enzyme (pharmacophore) [41], This was done for arylammonium inhibitors of trypsin, Di-dopamine receptor inhibitors, and organophosphate inhibitors of trypsin, acetylcholine esterase, and butyrylcholine esterase. Because the CCM values are equal for opposite enantiomers, the method had to be applied separately to the two families of enantiomers (R- and S-enantiomers). [Pg.419]

Glyceraldehyde can be considered to be the simplest chiral carbohydrate It is an aldotriose and because it contains one chirality center exists in two stereoisomeric forms the D and l enantiomers Moving up the scale m complexity next come the aldotetroses Examining their structures illustrates the application of the Fischer system to compounds that contain more than one chirality center... [Pg.1029]

Diastereomers include all stereoisomers that are not related as an object and its mirror image. Consider the four structures in Fig. 2.3. These structures represent fee four stereoisomers of 2,3,4-trihydroxybutanal. The configurations of C-2 and C-3 are indicated. Each stereogenic center is designated J or 5 by application of the sequence rule. Each of the four structures is stereoisomeric wife respect to any of fee others. The 2R R and 25,35 isomers are enantiomeric, as are fee 2R, iS and 25,3J pair. The 21 ,35 isomer is diastereomeric wife fee 25,35 and 2R,3R isomers because they are stereoisomers but not enantiomers. Any given structure can have only one enantiomer. All other stereoisomers of feat molecule are diastereomeric. The relative configuration of diastereomeric molecules is fiequently specified using fee terms syn and anti. The molecules are represented as extended chains. Diastereomers wife substituents on the same side of the extended chain are syn stereoisomers, whereas those wife substituents on opposite sides are anti stereoisomers. [Pg.84]

An interesting and practical example of the use of thermodynamic analysis is to explain and predict certain features that arise in the application of chromatography to chiral separations. The separation of enantiomers is achieved by making one or both phases chirally active so that different enantiomers will interact slightly differently with the one or both phases. In practice, it is usual to make the stationary phase comprise one specific isomer so that it offers specific selectivity to one enantiomer of the chiral solute pair. The basis of the selectivity is thought to be spatial, in that one enantiomer can approach the stationary phase closer than the other. If there is no chiral selectivity in the stationary phase, both enantiomers (being chemically identical) will coelute and will provide identical log(Vr ) against 1/T curve. If, however, one... [Pg.80]

The resolution of optically active compounds by gas chromatography with chiral phases is a well-established procedure, and the separation of Al-perfluoto-acetylated ammo acid ester enantiomers m 1967 was the first successful application of enantioselective gas-liquid chromatography [39] Ammo acids have been resolved as their A -trifluoroacetyl esters on chiral diamide phases such as N-lauroyl-L-valineferf-butylamideorAl-docosanoyl-L-valme /ez-r-butylamide [40,41,... [Pg.1030]

A rather unexpected discovery was made in connection to these investigations [49]. When the 1,3-dipolar cycloaddition reaction of la with 19b mediated by catalyst 20 (X=I) was performed in the absence of MS 4 A a remarkable reversal of enantioselectivity was observed as the opposite enantiomer of ench-21 was obtained (Table 6.1, entries 1 and 2). This had not been observed for enantioselective catalytic reactions before and the role of molecular sieves cannot simply be ascribed to the removal of water by the MS, since the application of MS 4 A that were presaturated with water, also induced the reversal of enantioselectivity (Table 6.1, entries 3 and 4). Recently, Desimoni et al. also found that in addition to the presence of MS in the MgX2-Ph-BOX-catalyzed 1,3-dipolar addition shown in Scheme 6.17, the counter-ion for the magnesium catalyst also strongly affect the absolute stereoselectivity of the reac-... [Pg.224]

E. R. Francotte and R Richeit, Applications of simulated moving-bed cliromatography to the separation of the enantiomers of chiral drugs , ]. Chromatogr. 769 101-107 (1997). [Pg.134]

Today, however, GC-GC coupling is seldom used to determine pesticides in environmental samples (2), although comprehensive MDGC has been applied to determine pesticides in more complex samples, such as human serum (19). On the other-hand, new trends in the pesticide market, which is now moving towards the production of optically active enantiomers and away from racemic mixtures, may make this area suitable for GC-GC application. The coupling of non-chiral columns to chiral columns appears to be a suitable solution to the separation problems that such a trend might cause. [Pg.337]

HPLC separations are one of the most important fields in the preparative resolution of enantiomers. The instrumentation improvements and the increasing choice of commercially available chiral stationary phases (CSPs) are some of the main reasons for the present significance of chromatographic resolutions at large-scale by HPLC. Proof of this interest can be seen in several reviews, and many chapters have in the past few years dealt with preparative applications of HPLC in the resolution of chiral compounds [19-23]. However, liquid chromatography has the attribute of being a batch technique and therefore is not totally convenient for production-scale, where continuous techniques are preferred by far. [Pg.4]

With regard to the resolution of enantiomers, some applications can be found with modified silica gel supports. Thus, a Pirkle-type CSP was used for the separation of 200 mg of a racemic benzodiazepinone [75]. Also tris-(3,5-dimethylphenyl)carba-mate of cellulose coated on silica [91, 92] was applied successfully to the resolution of the enantiomers of 2-phenoxypropionic acid and to oxprenolol, alprenolol, propranolol among other basic drugs. However, the low efficiency of this technique and the relative high price of the CSPs limits its use to the resolution of milligram range of sample. [Pg.7]

From the pioneering studies of Ito et al. [117], CCC has been mainly used for the separation and purification of natural products, where it has found a large number of applications [114, 116, 118, 119]. Moreover, the potential of this technique for preparative purposes can be also applied to chiral separations. The resolution of enantiomers can be simply envisaged by addition of a chiral selector to the stationary liquid phase. The mixture of enantiomers would come into contact with this liquid CSP, and enantiodiscrimination might be achieved. However, as yet few examples have been described in the literature. [Pg.10]

Although some applications for preparative-scale separations have already been reported [132] and the first commercial systems are being developed [137, 138], examples in the field of the resolution of enantiomers are still rare. The first preparative chiral separation published was performed with a CSP derived from (S -N-(3,5-dinitrobenzoyl)tyrosine covalently bonded to y-mercaptopropyl silica gel [21]. A productivity of 510 mg/h with an enantiomeric excess higher than 95% was achieved for 6 (Fig. 1-3). [Pg.12]

Gas chromatography (GC) has also been used for preparative purposes, but is restricted to relatively volatile racemates such as anesthetics, pheromones or monoterpenes and, therefore, very few applications are reported. Nevertheless, in the cases to which GC may be applied, it could be considered as an economical alternative to HPLC. Most of the resolutions of enantiomers were performed on cyclodex-trin-derived CSPs [109, 144-153], and only on very few occasions were other chiral selectors used [153]. [Pg.13]

Most of the chiral membrane-assisted applications can be considered as a modality of liquid-liquid extraction, and will be discussed in the next section. However, it is worth mentioning here a device developed by Keurentjes et al., in which two miscible chiral liquids with opposing enantiomers of the chiral selector flow counter-currently through a column, separated by a nonmiscible liquid membrane [179]. In this case the selector molecules are located out of the liquid membrane and both enantiomers are needed. The system allows recovery of the two enantiomers of the racemic mixture to be separated. Thus, using dihexyltartrate and poly(lactic acid), the authors described the resolution of different drugs, such as norephedrine, salbu-tamol, terbutaline, ibuprofen or propranolol. [Pg.15]

A compromise among all the properties mentioned herein should be established, depending on the technique used and on the particular application. Preparative separation of enantiomers is still an open subject which requires further investigation in the search of new chiral selectors and techniques well adapted to large scale processes. [Pg.18]

Enantiomeric separations have become increasingly important, especially in the pharmaceutical and agricultural industries as optical isomers often possess different biological properties. The analysis and preparation of a pure enantiomer usually involves its resolution from the antipode. Among all the chiral separation techniques, HPLC has proven to be the most convenient, reproducible and widely applicable method. Most of the HPLC methods employ a chiral selector as the chiral stationary phase (CSP). [Pg.24]

Although very efficient, the broad application of the direct preparation is restricted due to the limited number of pure starting enantiomers. The design of a multistep process that includes asymmetric synthesis is cumbersome and the development costs may be quite high. This approach is likely best suited for the multi-ton scale production of commodity enantiomers such as the drugs ibuprofen, naproxen, atenolol, and albuterol. However, even the best asymmetric syntheses do not lead to products in an enantiomerically pure state (100 % enantiomeric excess). Typically, the product is enriched to a certain degree with one enantiomer. Therefore, an additional purification step may be needed to achieve the required enantiopurity. [Pg.55]

In general, high selectivities can be obtained in liquid membrane systems. However, one disadvantage of this technique is that the enantiomer ratio in the permeate decreases rapidly when the feed stream is depleted in one enantiomer. Racemization of the feed would be an approach to tackle this problem or, alternatively, using a system containing the two opposite selectors, so that the feed stream remains virtually racemic [21]. Another potential drawback of supported enantioselective liquid membranes is the application on an industrial scale. Often a complex multistage process is required in order to achieve the desired purity of the product. This leads to a relatively complicated flow scheme and expensive process equipment for large-scale separations. [Pg.132]

For preparative or semipreparative-scale enantiomer separations, the enantiose-lectivity and column saturation capacity are the critical factors determining the throughput of pure enantiomer that can be achieved. The above-described MICSPs are stable, they can be reproducibly synthesized, and they exhibit high selectivities - all of which are attractive features for such applications. However, most MICSPs have only moderate saturation capacities, and isocratic elution leads to excessive peak tailing which precludes many preparative applications. Nevertheless, with the L-PA MICSP described above, mobile phases can be chosen leading to acceptable resolution, saturation capacities and relatively short elution times also in the isocratic mode (Fig. 6-6). [Pg.164]

One of the most useful applications of chiral derivatization chromatography is the quantification of free amino acid enantiomers. Using this indirect method, it is possible to quantify very small amounts of enantiomeric amino acids in parallel and in highly complex natural matrices. While direct determination of free amino acids is in itself not trivial, direct methods often fail completely when the enantiomeric ratio of amino acid from protein hydrolysis must be monitored in complex matrices. [Pg.191]

The method described above is applicable to a wide range of samples for the determination of amino acids in different matrices. For example, the amino acid composition and distribution of single enantiomers has been determined in protein hydrolysates, orange juice (Fig. 7-11), yogurt and seawater [23]. [Pg.192]

Erancotte E., Richert P. (1997) Applications of Simulated Moving-Bed Chromatography to the Separation of the Enantiomers of Chiral Drugs, J. Chrotnatogr. A 769 101-107. [Pg.250]


See other pages where Enantiomer application is mentioned: [Pg.1027]    [Pg.184]    [Pg.81]    [Pg.1027]    [Pg.158]    [Pg.92]    [Pg.68]    [Pg.218]    [Pg.262]    [Pg.2]    [Pg.3]    [Pg.14]    [Pg.17]    [Pg.18]    [Pg.24]    [Pg.25]    [Pg.62]    [Pg.129]    [Pg.153]    [Pg.179]    [Pg.203]    [Pg.216]    [Pg.217]    [Pg.219]    [Pg.299]   
See also in sourсe #XX -- [ Pg.203 , Pg.217 ]

See also in sourсe #XX -- [ Pg.203 , Pg.217 ]




SEARCH



Enantiomers industrial applications

© 2024 chempedia.info