Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Application of the Analytical Method

The stated aim of this review is to demonstrate that elassical analyses of physieal organie ehemistry are feasible with respect to complex systems such as supported metal catalysts through the application of advanced EMR spectroscopic techniques and determining the relevant spin Hamiltonian parameters via the Zeeman-dependent hyperfine spectrum. The principles of analysis were outlined in the preceding section and entail replicate collection of ESEEM or ENDOR spectra by incremental steps and mapping the trajectory of peak positions. Deconvolution of peaks may be made either by traditional tau-suppression in the stimulated echo pulse sequence or via advanced pulse sequences such as HYSCORE (2-D ESEEM, Hofer, 1994). Mapping of spectral peak position as it varies depending on the Zeeman field is very important to the accurate determination of hyperfine terms. [Pg.130]

The electronic structure of a molecule may be correlated to chemical reaction rates, and in this manner Hammett s concept of O can, in principle, be correlated to a nuclear quadmpole coupling or hyperfine interaction constant. The analogy between ESEEM and quantum beats or level-crossing spectroscopy opens up the opportunity to measure the effective zero-field NQI parameters for quadmpolar nuclei in the reactive center (ligands or metal ion) of proteins and supramolecular assemblies. As one might expect, however, one is constrained to a system in which [Pg.130]

This formula is eoneeptually simple, and its application can be facilitated, in the ease of Type 1 copper proteins, by referral to x-ray crystallographic structures. One therefore might test this and similar models by comparing the experimentally measured NQI parameters with estimates derived from the known x-ray structures and routine computational chemistry procedures. [Pg.131]

Br was made. The shift in the nuclear hyperfine interaction was attributed to in- [Pg.131]

A second experiment was tmdertaken in order to determine whether a strong DC electric field could be used to split lines in the ESEEM spectrum at exact cancellation. A linear electric field-induced hyperfine shift may be detected and tmder-stood in terms of orbital polarization. The shift has been proposed as a potential probe of the systems s excited-state wavefunction, defined as [Pg.132]


A panel discussion at the end of the book describes the potential biological hazards of drinking water and the needs and applications of the analytical methods presented in the book. This panel discussion is essential to the reader s understanding of the often complex chemistry-toxicology-water treatment-regulators interface. We hope that the reader will enjoy the panel discussion, not only for the technical content, but also for insight into the personal philosophies of the participants. [Pg.10]

An example application of the analytical method could be to determine the number of stages required to achieve a specified raffinate composition, where the feed Go and solvent stream flow rates and compositions are given. [Pg.371]

The nature of environmental samples often requires a clean-up step between sampling and the application of the analytical method. There are a variety of clean-up procedures available, most of which can be implemented in an automated fashion (see Chapters 3 and 4), in both segmented and unsegmented flow-methods, robotic methods and HPLC. Liquid-liquid and solid-liquid extraction [12-14], filtration [14,15], dialysis [12,15], evaporation [12,13], low-temperature precipitation of lipids and column-switching methods [16] are all cleanup methodologies of proven efficiency with environmental samples. [Pg.472]

A second classification is according to the plant material that has to undergo analysis. The specific application of the analytical method is determined by the special anatomical, physiological, and biochemical properties of the raw material and the technology used in processing. This classification was used in Volumes 6 to 8, and for some later volumes in the series. [Pg.244]

At the same time it seems to be attractive the viewpoint that numerical analysis of kinetic models of chemical reaction systems, defying analytical solutions, does not lie on the path of mechanical application of the analytical method. It seems here that more flexible and universal approaches are needed, which will be exemplified below. [Pg.21]

Indeed, the search for ultimate principles did not cease in the last decades of the eighteenth century. As is shown by the 1787 Tableau s class of substances that come closest to the state of simplicity (field I/a), the issue of such principles still occupied the four authors of the Methode. The real change that took place during these last decades was the rigorous application of the analytical method to such principles as well. The Discours pr61iminaire of Lavoisier s Traite of 1789 is doubtlessly the most famous document on the subject ... [Pg.125]

It is felt that the analytical method presented here is distinctly superior to any of the empirical methods for estimating gas consumption, such as the so-called "saturation rule." Application of the analytical method, however, is somewhat more difficult. The method should be suitable for all tank systems that use cryogens (such as hydrogen, oxygen, nitrogen, fluorine, carbon monoxide and neon) and that are equipped with a gas diffuser to prevent direct jetting of the gas into the liquid. In addition, the method is set up so that large variations in system operation may be incorporated by a person reasonably well versed in the principles of thermodynamics and heat transfer. [Pg.269]

Straightforward application of the analytical methods described in earlier chapters will often lead to erroneous results when examining envirormiental matrices. For example, analytical results based on the spectrophotometric CTAS method for nonionic surfactant determination will usually give a much higher value in sewage plant effluent than that obtained from use of more specific methods (71). It is important to check the results of the analysis of a new matrix by a second analytical method to assure that positive or negative interference is not a problem. [Pg.574]

If a standard method is available, the performance of a new method can be evaluated by comparing results with those obtained with an approved standard method. The comparison should be done at a minimum of three concentrations to evaluate the applicability of the new method for different amounts of analyte. Alternatively, we can plot the results obtained by the new method against those obtained by the approved standard method. A linear regression analysis should give a slope of 1 and ay-intercept of 0 if the results of the two methods are equivalent. [Pg.687]

If the critical impurities are known, then only a selected list of elements need to be examined, with some improvement in the cost effectiveness of the analysis. However, the list of elements to be included in the qualification analysis is often historical and related to the limitations of the analytical methods previously used for qualification rather than for technological reasons related to the end use of the metal. As a result, problems in application can arise for no obvious reason. The time and cost of extending the impurity list for GDMS analysis to include essentially all elements is minimal, considering the additional information gained. [Pg.621]

The focus of this chapter has been on proactive application of these analytical methods such as safety audits, development of procedures, training needs analysis, and equipment design. However, many of these methods can also be used in a retrospective mode, and this issue deserves further attention in its own right. Chapter 6 describes analytical methods for accident investigations and data collection. [Pg.200]

The function of the analyst is to obtain a result as near to the true value as possible by the correct application of the analytical procedure employed. The level of confidence that the analyst may enjoy in his results will be very small unless he has knowledge of the accuracy and precision of the method used as well as being aware of the sources of error which may be introduced. Quantitative analysis is not simply a case of taking a sample, carrying out a single determination and then claiming that the value obtained is irrefutable. It also requires a sound knowledge of the chemistry involved, of the possibilities of interferences from other ions, elements and compounds as well as of the statistical distribution of values. The purpose of this chapter is to explain some of the terms employed and to outline the statistical procedures which may be applied to the analytical results. [Pg.127]

A variety of studies can be found in the literature for the solution of the convection heat transfer problem in micro-channels. Some of the analytical methods are very powerful, computationally very fast, and provide highly accurate results. Usually, their application is shown only for those channels and thermal boundary conditions for which solutions already exist, such as circular tube and parallel plates for constant heat flux or constant temperature thermal boundary conditions. The majority of experimental investigations are carried out under other thermal boundary conditions (e.g., experiments in rectangular and trapezoidal channels were conducted with heating only the bottom and/or the top of the channel). These experiments should be compared to solutions obtained for a given channel geometry at the same thermal boundary conditions. Results obtained in devices that are built up from a number of parallel micro-channels should account for heat flux and temperature distribution not only due to heat conduction in the streamwise direction but also conduction across the experimental set-up, and new computational models should be elaborated to compare the measurements with theory. [Pg.187]

The applicants must provide the analytical methods used for the determination of the residues in the supervised field trial(s). The following features of the analytical methods are required by MAFF ... [Pg.42]

The rationale of validation experiments with fatty matrices is the high amount of fat extracted with many organic solvents. If analytes are not fat soluble and extraction is performed with water or aqueous buffer solutions, the troublesome fat is not extracted together with the analyte. Such extractions are typical for, e.g., the class of sulfonylurea herbicides. Examples exist where in such cases the applicability of an analytical method to fatty matrices was accepted by the authority without particular validation. [Pg.107]

All of the compounds (pyraflufen-ethyl and its metabolites) are converted to E-2 and quantified as the total toxic residue of pyraflufen-ethyl. The conversion to E-2 is carried out by oxidative decomposition with concentrated sulfuric acid. The reaction mixture is extracted with a solvent and subjected to simple cleanup, followed by GC/NPD analysis. This method is rapid and simple compared with the Multi-residue analytical method , and has wide applicability to different varieties of the samples, such as plant materials, soils and water, with only minor adjustment of the analytical method. [Pg.542]

The way in which automation of electroanalysis can be achieved depends very much on the specific requirements of the application. In order to illustrate this we have selected a number of typical examples. However, in doing so, we did not consider normal automation inherent to the nature of the analytical method, e.g., automatic scanning of the voltammetric curve in polarography and other voltammetric techniques, in addition to many additional refinements within these methods such as those treated already in Chapter 3 therefore, the selection of the examples in this chapter cannot be other than arbitrary, where the borderline between the common and the uncommon in the future certainly will shift towards the former. [Pg.328]

Several analytical studies have sought to extend the application of the basic method of Chen. For fluids of Prandtl number different from unity, Bennett and Chen (1980) extended the analysis by a modified Chilton-Colburn analogy to give... [Pg.292]

With respect to method application, once validation has been satisfactorily completed, there is little question that use of the analytical method in worker safety and re-entry studies falls under the full requirements of the GLP Standards. In addition, there should be an adequate level of quality control measurements taken in conjunction with the specimens so as to provide for a meaningful assessment of accuracy and precision, as well as verification of freedom from artifactual interferences. Along with these measurements there needs to be reasonably rigid data acceptance criteria in place (usually established during validation) which are consistently applied during the course of the specimen analytical phase of the study. [Pg.159]

Application of new analytical methods, in particular of different types of electrophoresis, has also provided new data on the molecular properties of these enzymes and has set more rigorous criteria of their purity and homogeneity. [Pg.324]

Field desorption (FD) was introduced by Beckey in 1969 [76]. FD was the first soft ionization method that could generate intact ions from nonvolatile compounds, such as small peptides [77]. The principal difference between FD and FI is the sample injection. Rather than being in the gas phase as in FI, analytes in FD are placed onto the emitter and desorbed from its surface. Application of the analyte onto the emitter can be performed by just dipping the activated emitter in a solution. The emitter is then introduced into the ion source of the spectrometer. The positioning of the emitter is cmcial for a successful experiment, and so is the temperature setting. In general, FI and FD are now replaced by more efficient ionization methods, such as MALDI and ESI. For a description of FD (and FI), see Reference 78. [Pg.27]

Hyphenated methods involve both separation and identification of components in one analytical procedure and are commonly used in investigating soil chemistry. These investigations can involve one separation step and one identification step, two separation steps and one identification step, and two separation and two identification steps. Hyphenated analytical method instruments are arranged in tandem, without the analyte being isolated between the applications of the two methods. This leads to a very long list of possible combinations of instrumentation and, potentially, any separation method can be paired with any identification method. The list of hyphenated methods is long, although only a few methods are commonly used in soil analysis as can be seen in the review by DAmore et al. [1],... [Pg.321]

In order to study simultaneously the behaviour of parent priority surfactants and their degradation products, it is essential to have accurate and sensitive analytical methods that enable the determination of the low concentrations generally occurring in the aquatic environment. As a result of an exhaustive review of the analytical methods used for the quantification within the framework of the three-year research project Priority surfactants and their toxic metabolites in wastewater effluents An integrated study (PRISTINE), it is concluded that the most appropriate procedure for this purpose is high-performance (HP) LC in reversed phase (RP), associated with preliminary techniques of concentration and purification by solid phase extraction (SPE). However, the complex mixtures of metabolites and a lack of reference standards currently limit the applicability of HPLC with UV- or fluorescence (FL-) detection methods. [Pg.25]

The guidelines stress, however, that internal quality control is not foolproof even when properly executed. Obviously it is subject to errors of both kinds , i.e. runs that are in control will occasionally be rejected and runs that are out of control occasionally accepted. Of more importance, IQC cannot usually identify sporadic gross errors or short-term disturbances in the analytical system that affect the results for individual test materials. Moreover, inferences based on IQC results are applicable only to test materials that fall within the scope of the analytical method validation. Despite these limitations, which professional experience and diligence can alleviate to a degree, internal quality control is the principal recourse available for ensuring that only data of appropriate quality are released from a laboratory. When properly executed it is very successful. [Pg.89]

Thus, when a property of the sample (which exists as a large volume of material) is to be measured, there usually will be differences between the analytical data derived from application of the test methods to a gross lot or gross consignment and the data from the sample lot. This difference (the sampling error) has a frequency distribution with a mean value and a variance. Variance is a statistical term defined as the mean square of errors the square root of the variance is more generally known as the standard deviation or the standard error of sampling. [Pg.167]

To illustrate the environmental application of the SIMCA method we examined a set of isomer specific analyses of sediment samples. The data examined were derived from more than 200 sediment samples taken from a study site on the Upper Mississippi River (41). These analytical data were transferred via magnetic tape from the laboratory data base to the Cyber 175 computer where principal component analysis were conducted on the isomer concentration data (ug/g each isomer). [Pg.223]

Above mentioned examples clearly show that if multivariate data processing methods are applicable, analytical information can be derived with a minimal amount of pre-information and a foreseeing of a maximum of problems. When the sampled object is homogenous, multivariate methods are only applicable when the analytical method itself produces multivariate signals. This is the case when several signals (e.g. spectra) are obtained for the sample as a function of another variable (e.g. time, excitation wavelength). For e mple in GC-MS, a mass spectrum is m sured of the eluents every. 1 a 1 second. In excitation-emission spectroscopy, spectra are measured at several excitation-wavelengths. The potentials of the application of multivariate... [Pg.25]


See other pages where Application of the Analytical Method is mentioned: [Pg.125]    [Pg.51]    [Pg.130]    [Pg.229]    [Pg.125]    [Pg.51]    [Pg.130]    [Pg.229]    [Pg.185]    [Pg.21]    [Pg.1450]    [Pg.78]    [Pg.111]    [Pg.479]    [Pg.270]    [Pg.227]    [Pg.18]    [Pg.419]    [Pg.396]    [Pg.400]    [Pg.463]    [Pg.64]    [Pg.447]    [Pg.11]    [Pg.18]    [Pg.72]   


SEARCH



Application of method

Application of the Method

Applications analytical

The Analyte

The Analytical Method

The Application of Thermo-analytical Methods in Environment Protection

© 2024 chempedia.info