Analytical mass spectroscopy

Analytical Procedures. Oxygen difluoride may be determined conveniently by quantitative appHcation of k, nmr, and mass spectroscopy. Purity may also be assessed by vapor pressure measurements. Wet-chemical analyses can be conducted either by digestion with excess NaOH, followed by measurement of the excess base (2) and the fluoride ion (48,49), or by reaction with acidified KI solution, followed by measurement of the Hberated I2 (4). [Pg.220]

Acetylene Derived from Hydrocarbons The analysis of purified hydrocarbon-derived acetylene is primarily concerned with the determination of other unsaturated hydrocarbons and iaert gases. Besides chemical analysis, physical analytical methods are employed such as gas chromatography, ir, uv, and mass spectroscopy. In iadustrial practice, gas chromatography is the most widely used tool for the analysis of acetylene. Satisfactory separation of acetylene from its impurities can be achieved usiag 50—80 mesh Porapak N programmed from 50—100°C at 4°C per minute. [Pg.378]

Air Monitoring. The atmosphere in work areas is monitored for worker safety. Volatile amines and related compounds can be detected at low concentrations in the air by a number of methods. Suitable methods include chemical, chromatographic, and spectroscopic techniques. For example, the NIOSH Manual of Analytical Methods has methods based on gas chromatography which are suitable for common aromatic and aHphatic amines as well as ethanolamines (67). Aromatic amines which diazotize readily can also be detected photometrically using a treated paper which changes color (68). Other methods based on infrared spectroscopy (69) and mass spectroscopy (70) have also been reported. [Pg.264]

The field of steroid analysis includes identification of steroids in biological samples, analysis of pharmaceutical formulations, and elucidation of steroid stmctures. Many different analytical methods, such as ultraviolet (uv) spectroscopy, infrared (ir) spectroscopy, nuclear magnetic resonance (nmr) spectroscopy, x-ray crystallography, and mass spectroscopy, are used for steroid analysis. The constant development of these analytical techniques has stimulated the advancement of steroid analysis. [Pg.448]

The detection and determination of traces of cobalt is of concern in such diverse areas as soflds, plants, fertilizers (qv), stainless and other steels for nuclear energy equipment (see Steel), high purity fissile materials (U, Th), refractory metals (Ta, Nb, Mo, and W), and semiconductors (qv). Useful techniques are spectrophotometry, polarography, emission spectrography, flame photometry, x-ray fluorescence, activation analysis, tracers, and mass spectrography, chromatography, and ion exchange (19) (see Analytical TffiTHODS Spectroscopy, optical Trace and residue analysis). [Pg.371]

Mass Spectrometer. The mass spectrometer is the principal analytical tool of direct process control for the estimation of tritium. Gas samples are taken from several process points and analy2ed rapidly and continually to ensure proper operation of the system. Mass spectrometry is particularly useful in the detection of diatomic hydrogen species such as HD, HT, and DT. Mass spectrometric detection of helium-3 formed by radioactive decay of tritium is still another way to detect low levels of tritium (65). Accelerator mass spectroscopy (ams) has also been used for the detection of tritium and carbon-14 at extremely low levels. The principal appHcation of ams as of this writing has been in archeology and the geosciences, but this technique is expected to faciUtate the use of tritium in biomedical research, various clinical appHcations, and in environmental investigations (66). [Pg.15]

The modern electronic industry has played a very important role in the development of instrumentation based on physical-analytical methods As a result, a rapid boom in the fields of infrared, nuclear magnetic resonance (NMR), Raman, and mass spectroscopy and vapor-phase (or gas-liquid) chromatography has been observed. Instruments for these methods have become indispensable tools in the analytical treatment of fluonnated mixtures, complexes, and compounds The detailed applications of the instrumentation are covered later in this chapter. [Pg.1023]

Nitrogen-containing fulvalenes have not been systematically studied by mass spectroscopy. Only isolated data for several examples of compounds have been reported. Most of the data consist of electron impact (El) mass spectra recorded for analytical purposes. Only a minor fraction dealt with the characterization of ion structures or focused on the effects of substituents, the ring size of fulvalenes, or the number and arrangement of nitrogen atoms and the fragmentation pathways. [Pg.157]

Analytic applications Ionic liquid as matrix for mass spectroscopy Armstrong et al. 4... [Pg.350]

The predominant method of analyzing environmental samples for methyl parathion is by GC. The detection methods most used are FID, FPD, ECD, and mass spectroscopy (MS). HPLC coupled with ultraviolet spectroscopy (UV) or MS has also been used successfiilly. Sample extraction and cleanup varies widely depending on the sample matrix and method of detection. Several analytical methods used to analyze environmental samples for methyl parathion are summarized in Table 7-2. [Pg.178]

It would be of obvious interest to have a theoretically underpinned function that describes the observed frequency distribution shown in Fig. 1.9. A number of such distributions (symmetrical or skewed) are described in the statistical literature in full mathematical detail apart from the normal- and the f-distributions, none is used in analytical chemistry except under very special circumstances, e.g. the Poisson and the binomial distributions. Instrumental methods of analysis that have Powjon-distributed noise are optical and mass spectroscopy, for instance. For an introduction to parameter estimation under conditions of linked mean and variance, see Ref. 41. [Pg.29]

Many techniques for the analysis of anthocyanins have been used for almost a century and are still of importance, along with considerable advances in technologies such as mass spectroscopy (MS) and nuclear magnetic resonance (NMR). This section summarizes the analytical procedures for quantitative and qualitative analyses of anthocyanins, including classical and modem techniques. [Pg.480]

A detailed description of sources used in atmospheric pressure ionization by electrospray or chemical ionization has been compiled.2 Atmospheric pressure has been used in a wide array of applications with electron impact, chemical ionization, pressure spray ionization (ionization when the electrode is below the threshold for corona discharge), electrospray ionization, and sonic spray ionization.3 Interferences potentially include overlap of ions of about the same mass-charge ratio, mobile-phase components, formation of adducts such as alkali metal ions, and suppression of ionization by substances more easily ionized than the analyte.4 A number of applications of mass spectroscopy are given in subsequent chapters. However, this section will serve as a brief synopsis, focusing on key techniques. [Pg.59]

Perhaps the most revolutionary development has been the application of on-line mass spectroscopic detection for compositional analysis. Polymer composition can be inferred from column retention time or from viscometric and other indirect detection methods, but mass spectroscopy has reduced much of the ambiguity associated with that process. Quantitation of end groups and of co-polymer composition can now be accomplished directly through mass spectroscopy. Mass spectroscopy is particularly well suited as an on-line GPC technique, since common GPC solvents interfere with other on-line detectors, including UV-VIS absorbance, nuclear magnetic resonance and infrared spectroscopic detectors. By contrast, common GPC solvents are readily adaptable to mass spectroscopic interfaces. No detection technique offers a combination of universality of analyte detection, specificity of information, and ease of use comparable to that of mass spectroscopy. [Pg.375]

This analytical methodology deduces the four photooxidative processes. The data on the total CO2 evolved from the samples were measured by gas chromatography and the isotopic C02 ( 6C02 and 4°C02) data by GC/mass spectroscopy. The rate constants of the two major photooxidative degradation processes at 25°C were deduced from h 18o2 per -(C H NO)- (i.e., to produce C02 product, t = 42 hr) at 196°C and the other from 02 per -(C H NO)- (i.e., to 2produce C02 product, t = 8 min) at 196°C. The rate constants of the former process was estimated as 1.10 x 10- 1 mole sec-- - and the latter as 1.03 x lO-- - 1 mole-- - sec-- -. The activation energies of these two processes were deduced as 10.8 kcal/mole for the former and 15.7 kcal/mole for the latter. [Pg.341]

Different experimental approaches were applied in the past [6, 45] and in recent years [23, 46] to study the nature of the organic residue. But the results or their interpretation have been contradictory. Even at present, the application of modem analytical techniques and optimized electrochemical instruments have led to different results and all three particles given above, namely HCO, COH and CO, have been recently discussed as possible methanol intermediates [14,15,23,46,47]. We shall present here the results of recent investigations on the electrochemical oxidation of methanol by application of electrochemical thermal desorption mass spectroscopy (ECTDMS) on-line mass spectroscopy, and Fourier Transform IR-reflection-absorption spectroscopy (SNIFTIRS). [Pg.141]

Evershed, R. P. (2000), Biomolecular analysis by organic mass spectroscopy, in Ciliberto, E. and G. Spoto (eds.), Modern Analytical Methods in Art and Archaeology, Chemical Analysis Series, Vol. 155, Wiley, New York, pp. 177-240. [Pg.573]

If suitable standards are unavailable (for example, if the FBA has not been encountered previously) the active agent must first be isolated and purified. The pure compound can be characterised by the usual techniques, including elemental analysis and infrared, n.m.r. and mass spectroscopy. Final proof of structure demands synthesis of the FBA indicated by the analytical data. Once again, difficulties may be encountered with compounds of the DAST... [Pg.346]

Mass spectroscopy is one of the few analytical methods that matches the theoretical chemists desire to observe molecules isolated, in vacuum. As such, calculations of reactions pathways, transition state and co-ordination are directly relevant and appropriate to measurements made using mass spectrometry. [Pg.712]

Hufford et al [57] used proton and 13C NMR spectrometric data to establish the novel sulfur-containing microbial metabolite of primaquine. Microbial metabolic studies of primaquine using Streptomyces roseochromogenus produced an A-acety-lated metabolite and a methylene-linked dimeric product, both of which have been previously reported, and a novel sulfur-containing microbial metabolite. The structure of the metabolite as an S-linked dimer was proposed on the basis of spectral and chemical data. The molecular formula C34H44N604S was established from field-desorption mass spectroscopy and analytical data. The 1H- and 13C NMR spectra data established that the novel metabolite was a symmetrical substituted dimer of primaquine A-acetate with a sulfur atom linking the two units at carbon 5. The metabolite is a mixture of stereoisomers, which can equilibrate in solution. This observation was confirmed by microbial synthesis of the metabolite from optically active primaquine. [Pg.183]

Evans, R. D. and Outridge, P. M. (1994). Applications of laser ablation inductively coupled plasma mass spectrometry to the determination of environmental contaminants in calcified biological structures. Journal of Analytical Atomic Spectroscopy 9 985-989. [Pg.362]

Raith, A., Hutton, R. C., Abell, I. D., and Crighton, J. (1995). Non-destructive sampling method of metals and alloys for laser ablation-inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectroscopy 10 591-594. [Pg.380]


See other pages where Analytical mass spectroscopy is mentioned: [Pg.1645]    [Pg.5]    [Pg.486]    [Pg.33]    [Pg.356]    [Pg.244]    [Pg.369]    [Pg.2207]    [Pg.536]    [Pg.133]    [Pg.44]    [Pg.241]    [Pg.92]    [Pg.306]    [Pg.179]    [Pg.259]    [Pg.57]    [Pg.376]    [Pg.467]    [Pg.62]    [Pg.84]    [Pg.237]    [Pg.46]    [Pg.372]    [Pg.225]    [Pg.406]    [Pg.242]    [Pg.376]   