Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Spectrometric techniques mass spectrometry

Since the 1960s, mass spectrometry has played a pivotal role in the field of structure elucidation and identification of organic compounds. Over the years, a wealth of knowledge has been gained on reactions of gas-phase ions from the use of a variety of mass spectrometric techniques. Mass spectrometry can be used to identify unknown compounds or to perform de nova stmcture determination. The former is relatively easy if one knows accurate mass and a reference spectrum. The latter is much more difficult and requires detailed knowledge of the rules for interpretation of a mass spectrum. Providing this knowledge is the focus of this chapter. [Pg.197]

Chromatography is an important tool in purification and isolation of compounds from (complex) mixtures prior to mass spectrometric analysis. Mass spectrometry can be used to detect the compounds separated by chromatography. This can be performed off-line, i.e. after fraction collection, but an even more powerful and versatile technique is achieved when the separation is coupled on-line to mass spectrometric detection. The on-line combination of a chromatographic separation method and mass spectrometry (MS) is an important and versatile tool in many areas of analytical chemistry. In principle, it enables the mass spectrometric characterization of components in complex mixtures after separation, with minimal or no sample losses. Both... [Pg.294]

Thus, either the emitted light or the ions formed can be used to examine samples. For example, the mass spectrometric ionization technique of atmospheric-pressure chemical ionization (APCI) utilizes a corona discharge to enhance the number of ions formed. Carbon arc discharges have been used to generate ions of otherwise analytically intractable inorganic substances, with the ions being examined by mass spectrometry. [Pg.388]

Mass Spectrometer. The mass spectrometer is the principal analytical tool of direct process control for the estimation of tritium. Gas samples are taken from several process points and analy2ed rapidly and continually to ensure proper operation of the system. Mass spectrometry is particularly useful in the detection of diatomic hydrogen species such as HD, HT, and DT. Mass spectrometric detection of helium-3 formed by radioactive decay of tritium is still another way to detect low levels of tritium (65). Accelerator mass spectroscopy (ams) has also been used for the detection of tritium and carbon-14 at extremely low levels. The principal appHcation of ams as of this writing has been in archeology and the geosciences, but this technique is expected to faciUtate the use of tritium in biomedical research, various clinical appHcations, and in environmental investigations (66). [Pg.15]

Laser based mass spectrometric methods, such as laser ionization (LIMS) and laser ablation in combination with inductively coupled plasma mass spectrometry (LA-ICP-MS) are powerful analytical techniques for survey analysis of solid substances. To realize the analytical performances methods for the direct trace analysis of synthetic and natural crystals modification of a traditional analytical technique was necessary and suitable standard reference materials (SRM) were required. Recent developments allowed extending the range of analytical applications of LIMS and LA-ICP-MS will be presented and discussed. For example ... [Pg.425]

In addition to the wet and optical spectrometric methods, which are often used to analyse elements present in very small proportions, there are also other techniques which can only be mentioned here. One is the method of mass spectrometry, in which the proportions of separate isotopes can be measured this can be linked to an instrument called a field-ion microscope, in which as we have seen individual atoms can be observed on a very sharp hemispherical needle tip through the mechanical action of a very intense electric field. Atoms which have been ionised and detached can then be analysed for isotopic mass. This has become a powerful device for both curiosity-driven and applied research. [Pg.234]

On the other hand, if only specific GC detectors, e.g. the electron capture, nitrogen-phosphorus or flame photometric detectors, are tested, the argument of lack of GC method sensitivity is not acceptable. In most cases mass spectrometric detectors provide the sensitivity and selectivity needed. Unfortunately, tandem mass spectrometry (MS/MS) or MS" detectors for GC are still not widely used in official laboratories, and therefore these techniques are not always accepted for enforcement methods. [Pg.108]

In addition to instrumental improvements, various approaches have been used to improve the purity or geometry of sources of natural samples for gamma spectrometric measurement. For example, improvements in source preparation for " Th measurement in water and sediment samples by gamma spectrometry are discussed in Cochran and Masque (2003). It should be emphasized that one of the main advantages of gamma spectrometry is ease of use, since in many cases samples may be analyzed directly or with significantly reduced sample preparation compared to alpha, beta, or mass spectrometric techniques. [Pg.31]

Soon after this discovery the harnessing of the technique to the measurement of all the U isotopes and all the Th isotopes with great precision immediately opened up the entire field of uranium and thorium decay chain studies. This area of study was formerly the poaching ground for radioactive measurements alone but now became part of the wonderful world of mass spectrometric measurements. (The same transformation took place for radiocarbon from the various radioactive counting schemes to accelerator mass spectrometry.)... [Pg.662]

Principles and Characteristics Ionisation processes are the basis for mass-spectrometric detection. Each of the ionisation techniques occupies its own position in mass spectrometry. The optimum performance of any ionisation method (and therefore the result) will depend critically on the characteristics and reliability of the mass spectrometer. Ionisation may occur in the gas, liquid or condensed phase, and may be either hard or soft , i.e. with or without extensive... [Pg.357]

This chapter deals mainly with (multi)hyphenated techniques comprising wet sample preparation steps (e.g. SFE, SPE) and/or separation techniques (GC, SFC, HPLC, SEC, TLC, CE). Other hyphenated techniques involve thermal-spectroscopic and gas or heat extraction methods (TG, TD, HS, Py, LD, etc.). Also, spectroscopic couplings (e.g. LIBS-LIF) are of interest. Hyphenation of UV spectroscopy and mass spectrometry forms the family of laser mass-spectrometric (LAMS) methods, such as REMPI-ToFMS and MALDI-ToFMS. In REMPI-ToFMS the connecting element between UV spectroscopy and mass spectrometry is laser-induced REMPI ionisation. An intermediate state of the molecule of interest is selectively excited by absorption of a laser photon (the wavelength of a tuneable laser is set in resonance with the transition). The excited molecules are subsequently ionised by absorption of an additional laser photon. Therefore the ionisation selectivity is introduced by the resonance absorption of the first photon, i.e. by UV spectroscopy. However, conventional UV spectra of polyatomic molecules exhibit relatively broad and continuous spectral features, allowing only a medium selectivity. Supersonic jet cooling of the sample molecules (to 5-50 K) reduces the line width of their... [Pg.428]

Gas and liquid chromatography directly coupled with atomic spectrometry have been reviewed [178,179], as well as the determination of trace elements by chromatographic methods employing atomic plasma emission spectrometric detection [180]. Sutton et al. [181] have reviewed the use and applications of ICP-MS as a chromatographic and capillary electrophoretic detector, whereas Niessen [182] has briefly reviewed the applications of mass spectrometry to hyphenated techniques. [Pg.456]

SEC-ESI-FTMS combines the size separation based technique of SEC with one of the most powerful mass spectrometric techniques of FTMS offering high mass accuracy (ppm), ultrahigh resolving power (>10(i) 6) and the capability to perform tandem mass spectrometry. The technique enables generation of oligomer elution profiles, which can be used for accurate calibration of standard SEC data. Coupling of SEC to ESI-MS is further described in ref. [710],... [Pg.529]


See other pages where Spectrometric techniques mass spectrometry is mentioned: [Pg.16]    [Pg.21]    [Pg.812]    [Pg.16]    [Pg.21]    [Pg.812]    [Pg.158]    [Pg.163]    [Pg.552]    [Pg.2390]    [Pg.276]    [Pg.260]    [Pg.549]    [Pg.609]    [Pg.1029]    [Pg.145]    [Pg.412]    [Pg.20]    [Pg.287]    [Pg.5]    [Pg.208]    [Pg.4]    [Pg.25]    [Pg.25]    [Pg.50]    [Pg.177]    [Pg.408]    [Pg.462]    [Pg.578]    [Pg.93]    [Pg.353]    [Pg.384]    [Pg.408]    [Pg.410]    [Pg.427]    [Pg.464]    [Pg.589]    [Pg.648]   
See also in sourсe #XX -- [ Pg.2 , Pg.21 ]




SEARCH



Mass spectrometr

Mass spectrometric

Mass spectrometric techniques

Mass spectrometry technique

© 2024 chempedia.info